{"id":2370,"date":"2023-01-03T15:07:58","date_gmt":"2023-01-03T14:07:58","guid":{"rendered":"https:\/\/chemspx.com\/instruments\/reaxus-ld-class\/"},"modified":"2026-04-17T11:43:08","modified_gmt":"2026-04-17T09:43:08","slug":"reaxus-ld-class-dual-piston-pump","status":"publish","type":"instruments","link":"https:\/\/chemspx.com\/fr\/instruments\/reaxus-ld-class\/","title":{"rendered":"ReaXus LD Class"},"content":{"rendered":"<h2>Dual Piston Pump for low pulsation requirements<\/h2>\n<p>The ReaXus\u00ae LD Class features dual-headed, positive displacement piston pumps designed for chromatography applications, including analytical, flash, and small-scale preparative workflows. These pumps are ideal to deliver precise flow rates with exceptionally low pulsation, meeting the high accuracy requirements of HPLC and other high-performance separations.<\/p>\n<h3 data-section-id=\"16kay2r\" data-start=\"575\" data-end=\"609\"><strong>Performance and capabilities<\/strong><\/h3>\n<p data-start=\"611\" data-end=\"673\">The LD Class is available in three flow rate configurations:<\/p>\n<ul data-start=\"675\" data-end=\"717\">\n<li data-section-id=\"3x9mrz\" data-start=\"675\" data-end=\"688\">12 mL\/min<\/li>\n<li data-section-id=\"1vvz895\" data-start=\"689\" data-end=\"702\">36 mL\/min<\/li>\n<li data-section-id=\"1hruyxp\" data-start=\"703\" data-end=\"717\">100 mL\/min<\/li>\n<\/ul>\n<p data-start=\"719\" data-end=\"981\">These pumps can reach pressures up to <strong>6,000 psi,<\/strong> providing the power needed for both high- and low-pressure gradients. The high-performance linear cams combined with automatic pressure compensation ensure precise, stable flow.<\/p>\n<h3 data-start=\"719\" data-end=\"981\"><strong>Fluid paths and materials\u00a0<\/strong><\/h3>\n<p data-start=\"1015\" data-end=\"1269\">Standard fluid path materials include stainless steel and PEEK, with optional Hastelloy for corrosive or specialized applications. Jacketed pump heads are available for temperature-controlled processes, enabling precise management of sample conditions.<\/p>\n<h3 data-section-id=\"sv7ol0\" data-start=\"1271\" data-end=\"1300\"><strong>Key advantages\u00a0<\/strong><\/h3>\n<p data-start=\"1807\" data-end=\"1922\">The LD Class dual piston mechanism, advanced cam technology, and patented low dead-volume Pulse Dampener provide:<\/p>\n<ul data-start=\"1924\" data-end=\"2103\">\n<li data-section-id=\"2c93h2\" data-start=\"1924\" data-end=\"1979\">Minimal pulsation for high-precision chromatography<\/li>\n<li data-section-id=\"1t3f8c8\" data-start=\"1980\" data-end=\"2036\">Stable and accurate flow over a wide operating range<\/li>\n<li data-section-id=\"vddlis\" data-start=\"2037\" data-end=\"2103\">Reliable performance for both analytical and preparative tasks<\/li>\n<li data-section-id=\"vxgx8n\" data-start=\"1427\" data-end=\"1464\">RS-232 and Micro USB connectivity<\/li>\n<li data-section-id=\"t7dlp\" data-start=\"1465\" data-end=\"1491\">Run\/Stop functionality<\/li>\n<li data-section-id=\"1f1oc8l\" data-start=\"1492\" data-end=\"1528\">Analog control (0\u201310 V, 4\u201320 mA)<\/li>\n<li data-section-id=\"8odw51\" data-start=\"1529\" data-end=\"1572\">Full PC monitoring and status reporting<\/li>\n<\/ul>\n<div class=\"flex max-w-full flex-col flex-grow\">\n<div class=\"min-h-8 text-message flex w-full flex-col items-end gap-2 whitespace-normal break-words text-start [.text-message+&amp;]:mt-5\" dir=\"auto\" data-message-author-role=\"assistant\" data-message-id=\"f3e9c468-96cb-4857-a416-b8fe45f1f9ab\" data-message-model-slug=\"gpt-4o-mini\">\n<div class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[3px]\">\n<h3><strong>Specifications\u00a0<\/strong><\/h3>\n<\/div>\n<\/div>\n<\/div>\n<table class=\"ms-rteTable-1\" width=\"100%\" cellspacing=\"0\">\n<tbody>\n<tr class=\"ms-rteTableOddRow-1\">\n<td class=\"ms-rteTableEvenCol-1\"><strong>Flow Rate Range and Max. Pressure Ratings*<\/strong><\/td>\n<td class=\"ms-rteTableOddCol-1\">\u200b0.0-12.000 mL\/min (6,000 psi)<\/p>\n<p>0.0-36.000 mL\/min (6,000 psi)<\/p>\n<p>0.0-100.0 mL\/min (1,500 psi)<\/td>\n<\/tr>\n<tr class=\"ms-rteTableEvenRow-1\">\n<td class=\"ms-rteTableEvenCol-1\"><strong>\u200bPulsation**<\/strong><\/td>\n<td class=\"ms-rteTableOddCol-1\">\u22642% @ 1 mL\/min and 80:20 Water\/IPA; 1,000 psi (12 mL)<\/p>\n<p>\u22641.0% @ 4 mL\/min and 80:20 Water\/IPA; 1,000 psi (36 mL)<\/p>\n<p>\u22642.0% @ 50 mL\/min and 80:20 Water\/IPA; 250 ps (100 mL)<\/td>\n<\/tr>\n<tr class=\"ms-rteTableOddRow-1\">\n<td class=\"ms-rteTableEvenCol-1\"><strong>Pressure Accuracy<\/strong><\/td>\n<td class=\"ms-rteTableOddCol-1\">\u00b150 psi<\/td>\n<\/tr>\n<tr class=\"ms-rteTableEvenRow-1\">\n<td class=\"ms-rteTableEvenCol-1\"><strong>\u200bFlow Reproducibility<\/strong><\/td>\n<td class=\"ms-rteTableOddCol-1\">0.5% RSD (1.000 \u2013 12.000 mL\/min; 80:20 Water\/IPA; 1,000 psi) (12 mL)<\/p>\n<p>0.5% RSD (1.00 \u2013 36.00 mL\/min; 80:20 Water\/IPA; 1,000 psi) (36 mL)<\/p>\n<p>0.5% RSD (1.0 \u2013 100.0 mL\/min; 80:20 Water\/IPA; 500 psi) (100 mL)<\/td>\n<\/tr>\n<tr class=\"ms-rteTableOddRow-1\">\n<td class=\"ms-rteTableEvenCol-1\"><strong>Flow Rate Accuracy<\/strong><\/td>\n<td class=\"ms-rteTableOddCol-1\">\u00b12% (1.000 \u2013 12.000 mL\/min; 80:20 Water\/IPA; 1,000 psi) (12 mL)<\/p>\n<p>\u00b12% (2.00 \u2013 32.00 mL\/min; 80:20 Water\/IPA; 1,000 psi) (36 mL)<\/p>\n<p>\u00b12% (0.5 \u2013 100.0 mL\/min; 80:20 Water\/IPA; 500 psi) (100 mL)<\/td>\n<\/tr>\n<tr class=\"ms-rteTableEvenRow-1\">\n<td class=\"ms-rteTableEvenCol-1\"><strong>\u200bWetted Materials<\/strong><\/td>\n<td class=\"ms-rteTableOddCol-1\">PEEK pumps may include: PEEK, Synthetic Ruby, Sapphire, Zirconia, UHMWPE, FFKM, PFA, ETFE<\/p>\n<p>Stainless Steel pumps may include: 316 Stainless Steel, PEEK, Synthetic Ruby, Sapphire, Zirconia, UHMWPE, PFA, PTFE, ETFE<\/p>\n<p>Hastelloy pumps may include: Hastelloy C-276, Synthetic Ruby, Sapphire, Zirconia, UHMWPE, FFKM, PFA, PTFE, ETFE<\/td>\n<\/tr>\n<tr class=\"ms-rteTableOddRow-1\">\n<td class=\"ms-rteTableEvenCol-1\"><strong>Dimensions<\/strong><\/td>\n<td class=\"ms-rteTableOddCol-1\">6.4&#8243; H x 9.9&#8243; W x 17.5&#8243; D<\/p>\n<p>(16.3 x 25.1 x 44.5 cm)<\/td>\n<\/tr>\n<tr class=\"ms-rteTableEvenRow-1\">\n<td class=\"ms-rteTableEvenCol-1\">\u200b<strong>Weight<\/strong><\/td>\n<td class=\"ms-rteTableOddCol-1\">21.4 lbs. (9.7 kg)<\/td>\n<\/tr>\n<tr class=\"ms-rteTableOddRow-1\">\n<td class=\"ms-rteTableEvenCol-1\" rowspan=\"1\">\u200b<strong>Power<\/strong><\/td>\n<td class=\"ms-rteTableOddCol-1\" rowspan=\"1\">\u200b100-240 Vac (\u00b110%), 50-60 Hz<\/td>\n<\/tr>\n<tr class=\"ms-rteTableEvenRow-1\">\n<td class=\"ms-rteTableEvenCol-1\" rowspan=\"1\"><strong>\u200bControl<\/strong><\/td>\n<td class=\"ms-rteTableOddCol-1\" rowspan=\"1\">RS-232, Micro USB, Run\/Stop, Analog (0-10V, 4-20mA)<\/td>\n<\/tr>\n<tr class=\"ms-rteTableFooterRow-1\">\n<td class=\"ms-rteTableFooterEvenCol-1\" colspan=\"2\" rowspan=\"1\"><span class=\"ms-rteFontSize-1\">*Flow Rate is dependent on solvent selection and operating pressure.<\/span><\/p>\n<p><span class=\"ms-rteFontSize-1\">**Pulsation value with pulse dampener.<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h3><strong>Not sure which pump fits your needs?\u00a0<\/strong><\/h3>\n<p>Compare models <a href=\"https:\/\/chemspx.com\/choose-the-right-reciprocating-pump\/\" target=\"_blank\" rel=\"noopener\">here<\/a>!<\/p>\n<table>\n<tbody>\n<tr>\n<th><strong>ReaXus Class<\/strong><\/th>\n<th><strong>Key differences\u00a0<\/strong><\/th>\n<\/tr>\n<tr>\n<th scope=\"row\"><a href=\"https:\/\/chemspx.com\/instruments\/reaxus-m1-class\/\" target=\"_blank\" rel=\"noopener\"><strong>M1 Class<\/strong><\/a><\/th>\n<td>Compact design focused on affordability while maintaining high precision and performance<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\"><a href=\"https:\/\/chemspx.com\/instruments\/reaxus-mx-class\/\" target=\"_blank\" rel=\"noopener\"><strong>MX Class<\/strong><\/a><\/th>\n<td>Economical design with eccentric drive and shaped cam mechanism<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\"><a href=\"https:\/\/chemspx.com\/instruments\/reaxus-ls-class\/\" target=\"_blank\" rel=\"noopener\"><strong>LS Class<\/strong><\/a><\/th>\n<td>Advanced cam design providing very low pulsation for improved flow stability<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\"><strong>LD Class<\/strong><\/th>\n<td>Dual\u2011headed pump for high versatility in analytical, flash, and small\u2011scale preparative chromatography<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\"><a href=\"https:\/\/chemspx.com\/instruments\/reaxus-pr-class\/\" target=\"_blank\" rel=\"noopener\"><strong>PR Class<\/strong><\/a><\/th>\n<td>Dual\u2011headed, rugged construction optimized for high flow accuracy and excellent pressure capability across varied applications<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [{\n    \"@type\": \"Question\",\n    \"name\": \"What is the ReaXus LD Class pump?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"The ReaXus\u00ae LD Class is a dual\u2011headed, positive displacement piston pump designed for chromatography applications that require exceptionally low pulsation. It is suitable for analytical, flash, and small\u2011scale preparative workflows where high flow accuracy and stability are critical.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Which chromatography applications is the ReaXus LD Class designed for?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"These pumps are ideal for HPLC, as well as analytical, flash, and small\u2011scale preparative chromatography. Their low pulsation performance supports high\u2011resolution separations and consistent gradient delivery.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"How does the ReaXus LD Class design improve performance?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"The dual piston mechanism, combined with high\u2011performance linear cams and automatic pressure compensation, delivers smooth, stable flow with minimal pulsation. This ensures precise flow control across a wide operating range, even under changing pressure conditions.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"What flow rate options are available?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"The ReaXus\u00ae LD Class is available in three flow rate configurations: 12\u202fmL\/min, 36\u202fmL\/min, and 100\u202fmL\/min, allowing users to match pump capacity to their specific chromatography requirements.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"What pressure levels can the ReaXus LD Class achieve?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"These pumps can reach pressures of up to 6,000\u202fpsi, making them suitable for both high\u2011pressure analytical separations and lower\u2011pressure preparative or flash methods.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"How does the ReaXus LD Class minimize pulsation?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Minimal pulsation is achieved through a combination of the dual piston design, advanced cam technology, and a patented low dead\u2011volume Pulse Dampener. This architecture ensures stable flow and consistent detector response in sensitive chromatography systems.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Which materials are used in the fluid path?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Standard fluid path materials include stainless steel and PEEK, offering broad chemical compatibility. Hastelloy is available as an option for corrosive or specialized applications.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Can the ReaXus LD Class support temperature\u2011controlled processes?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Yes. Jacketed pump heads are available for temperature\u2011controlled applications, enabling precise management of sample and solvent conditions during chromatography runs.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Why choose the ReaXus\u00ae LD Class for low\u2011pulsation requirements?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"The ReaXus\u00ae LD Class combines high pressure capability, exceptionally low pulsation, and precise flow control in a reliable dual piston design. This makes it a strong choice for chromatography laboratories that require accurate, reproducible performance across analytical and preparative workflows.\"\n    }\n  }]\n}\n<\/script><\/p>\n<p><script type=\"application\/ld+json\"> \n{ \n  \"@context\": \"https:\/\/schema.org\/\", \n  \"@type\": \"Product\", \n  \"name\": \"ReaXus LD Class\", \n  \"image\": \"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/ReaXus-LD-Class-Gen2-WEB-1.png\", \n  \"description\": \"The ReaXus\u00ae LD Class features dual-headed, positive displacement piston pumps designed for chromatography applications, including analytical, flash, and small-scale preparative workflows.\", \n  \"brand\": { \n    \"@type\": \"Brand\", \n    \"name\": \"Teledyne Labs\" \n  }, \n  \"offers\": { \n    \"@type\": \"Offer\", \n    \"url\": \"https:\/\/chemspx.com\/instruments\/reaxus-ld-class\/\", \n    \"priceCurrency\": \"EUR\", \n    \"price\": \"0.00\", \n    \"availability\": \"https:\/\/schema.org\/InStock\", \n    \"seller\": { \n      \"@type\": \"Organization\", \n      \"name\": \"ChemSPX\", \n      \"url\": \"https:\/\/chemspx.com\", \n      \"logo\": \"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/Logo_ChemSPX-1.png\", \n      \"areaServed\": [ \n        { \"@type\": \"Country\", \"name\": \"Belgium\" }, \n        { \"@type\": \"Country\", \"name\": \"Netherlands\" }, \n        { \"@type\": \"Country\", \"name\": \"Luxembourg\" } \n      ] \n    } \n  } \n} \n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Dual-headed, positive displacement piston pumps designed for chromatography applications<\/p>","protected":false},"featured_media":2567,"template":"","country":[650,649],"brands":[668],"applications":[567,657],"markets":[14,22,115,39,110,24,40,23],"class_list":["post-2370","instruments","type-instruments","status-publish","has-post-thumbnail","hentry","country-be","country-nl","brands-teledyne_labs","applications-chemistry","applications-reciprocating-pumps","markets-chemicals","markets-chemicals-chemicals","markets-chemicals-materials","markets-liquid-fuels","markets-materials","markets-pharmaceuticals","markets-refinery","markets-specialty-chemicals"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>ReaXus LD Class | Dual Piston Pump | ChemSPX<\/title>\n<meta name=\"description\" content=\"Dual-headed, positive displacement piston pumps for chromatography applications, including analytical, flash, and more.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/chemspx.com\/fr\/instruments\/reaxus-ld-class\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ReaXus LD Class | Dual Piston Pump | ChemSPX\" \/>\n<meta property=\"og:description\" content=\"Dual-headed, positive displacement piston pumps for chromatography applications, including analytical, flash, and more.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/chemspx.com\/fr\/instruments\/reaxus-ld-class\/\" \/>\n<meta property=\"og:site_name\" content=\"ChemSPX\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-17T09:43:08+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/ReaXus-LD-Class-Gen2-WEB-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"502\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/instruments\\\/reaxus-ld-class\\\/\",\"url\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/instruments\\\/reaxus-ld-class\\\/\",\"name\":\"ReaXus LD Class | Dual Piston Pump | ChemSPX\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/instruments\\\/reaxus-ld-class\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/instruments\\\/reaxus-ld-class\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/ReaXus-LD-Class-Gen2-WEB-1.png\",\"datePublished\":\"2023-01-03T14:07:58+00:00\",\"dateModified\":\"2026-04-17T09:43:08+00:00\",\"description\":\"Dual-headed, positive displacement piston pumps for chromatography applications, including analytical, flash, and more.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/instruments\\\/reaxus-ld-class\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/chemspx.com\\\/fr\\\/instruments\\\/reaxus-ld-class\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/instruments\\\/reaxus-ld-class\\\/#primaryimage\",\"url\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/ReaXus-LD-Class-Gen2-WEB-1.png\",\"contentUrl\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/ReaXus-LD-Class-Gen2-WEB-1.png\",\"width\":500,\"height\":502,\"caption\":\"Dual Piston Pumps\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/instruments\\\/reaxus-ld-class\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/chemspx.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Instruments\",\"item\":\"https:\\\/\\\/chemspx.com\\\/instruments\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ReaXus LD Class\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/\",\"name\":\"ChemSPX\",\"description\":\"ChemSPX\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ReaXus LD Class | Dual Piston Pump | ChemSPX","description":"Dual-headed, positive displacement piston pumps for chromatography applications, including analytical, flash, and more.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/chemspx.com\/fr\/instruments\/reaxus-ld-class\/","og_locale":"fr_FR","og_type":"article","og_title":"ReaXus LD Class | Dual Piston Pump | ChemSPX","og_description":"Dual-headed, positive displacement piston pumps for chromatography applications, including analytical, flash, and more.","og_url":"https:\/\/chemspx.com\/fr\/instruments\/reaxus-ld-class\/","og_site_name":"ChemSPX","article_modified_time":"2026-04-17T09:43:08+00:00","og_image":[{"width":500,"height":502,"url":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/ReaXus-LD-Class-Gen2-WEB-1.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/chemspx.com\/fr\/instruments\/reaxus-ld-class\/","url":"https:\/\/chemspx.com\/fr\/instruments\/reaxus-ld-class\/","name":"ReaXus LD Class | Dual Piston Pump | ChemSPX","isPartOf":{"@id":"https:\/\/chemspx.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/chemspx.com\/fr\/instruments\/reaxus-ld-class\/#primaryimage"},"image":{"@id":"https:\/\/chemspx.com\/fr\/instruments\/reaxus-ld-class\/#primaryimage"},"thumbnailUrl":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/ReaXus-LD-Class-Gen2-WEB-1.png","datePublished":"2023-01-03T14:07:58+00:00","dateModified":"2026-04-17T09:43:08+00:00","description":"Dual-headed, positive displacement piston pumps for chromatography applications, including analytical, flash, and more.","breadcrumb":{"@id":"https:\/\/chemspx.com\/fr\/instruments\/reaxus-ld-class\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/chemspx.com\/fr\/instruments\/reaxus-ld-class\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/chemspx.com\/fr\/instruments\/reaxus-ld-class\/#primaryimage","url":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/ReaXus-LD-Class-Gen2-WEB-1.png","contentUrl":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/ReaXus-LD-Class-Gen2-WEB-1.png","width":500,"height":502,"caption":"Dual Piston Pumps"},{"@type":"BreadcrumbList","@id":"https:\/\/chemspx.com\/fr\/instruments\/reaxus-ld-class\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/chemspx.com\/"},{"@type":"ListItem","position":2,"name":"Instruments","item":"https:\/\/chemspx.com\/instruments\/"},{"@type":"ListItem","position":3,"name":"ReaXus LD Class"}]},{"@type":"WebSite","@id":"https:\/\/chemspx.com\/fr\/#website","url":"https:\/\/chemspx.com\/fr\/","name":"ChemSPX","description":"ChemSPX","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/chemspx.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/instruments\/2370","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/instruments"}],"about":[{"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/types\/instruments"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/media\/2567"}],"wp:attachment":[{"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/media?parent=2370"}],"wp:term":[{"taxonomy":"country","embeddable":true,"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/country?post=2370"},{"taxonomy":"brands","embeddable":true,"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/brands?post=2370"},{"taxonomy":"applications","embeddable":true,"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/applications?post=2370"},{"taxonomy":"markets","embeddable":true,"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/markets?post=2370"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}