{"id":2417,"date":"2025-04-03T15:08:14","date_gmt":"2025-04-03T13:08:14","guid":{"rendered":"https:\/\/chemspx.com\/instruments\/vision-g2-classic-6\/"},"modified":"2026-05-18T15:45:35","modified_gmt":"2026-05-18T13:45:35","slug":"vision-g2-classic-6-dissolution-tester","status":"publish","type":"instruments","link":"https:\/\/chemspx.com\/fr\/instruments\/vision-g2-classic-6\/","title":{"rendered":"Vision G2 Classic 6"},"content":{"rendered":"<h2>Dissolution Tester<\/h2>\n<p data-start=\"43\" data-end=\"364\">The Vision\u00ae G2 Classic 6 dissolution tester is the compact and rugged counterpart to the<a href=\"https:\/\/chemspx.com\/instruments\/vision-g2-elite-8\/\" target=\"_blank\" rel=\"noopener\"> Vision G2 Elite 8<\/a>. The system simplifies manual dissolution testing while maintaining precision and ease of use. The system meets and exceeds worldwide standards and compliance requirements, including USP, FDA, ASTM, EP, JP, CE, CSA, RoHS, and 21 CFR Part 11.<\/p>\n<h3 data-start=\"569\" data-end=\"729\"><strong>Accessibility and efficient operation\u00a0<\/strong><\/h3>\n<p>The system provides easy access to all vessels while maintaining a compact footprint that helps conserve laboratory bench space.<\/p>\n<p data-start=\"731\" data-end=\"766\"><strong>Additional design features include:<\/strong><\/p>\n<ul data-start=\"768\" data-end=\"1030\">\n<li data-section-id=\"1ozz3pi\" data-start=\"768\" data-end=\"819\">Compact footprint for space-saving installation<\/li>\n<li data-section-id=\"iw9cw6\" data-start=\"820\" data-end=\"886\">6-position Easi-Lock\u2122 vessel plate for proper vessel centering<\/li>\n<li data-section-id=\"9yauc2\" data-start=\"887\" data-end=\"945\">Superior coating for vessel plate corrosion protection<\/li>\n<li data-section-id=\"6pij8l\" data-start=\"946\" data-end=\"993\">Fixed drive head for repeatable positioning<\/li>\n<li data-section-id=\"yncjqk\" data-start=\"994\" data-end=\"1030\">Adaptable for automated sampling<\/li>\n<\/ul>\n<p data-start=\"1032\" data-end=\"1085\"><strong>The system also supports tool-free switching between:<\/strong><\/p>\n<ul data-start=\"1087\" data-end=\"1216\">\n<li data-section-id=\"1g6vufi\" data-start=\"1087\" data-end=\"1106\">USP Apparatus 1<\/li>\n<li data-section-id=\"1g6vryl\" data-start=\"1107\" data-end=\"1126\">USP Apparatus 2<\/li>\n<li data-section-id=\"1g6vr2i\" data-start=\"1127\" data-end=\"1146\">USP Apparatus 5<\/li>\n<li data-section-id=\"1g6voll\" data-start=\"1147\" data-end=\"1166\">USP Apparatus 6<\/li>\n<li data-section-id=\"1lypwrd\" data-start=\"1167\" data-end=\"1191\">150 mL small volumes<\/li>\n<li data-section-id=\"15naqka\" data-start=\"1192\" data-end=\"1216\">250 mL small volumes<\/li>\n<\/ul>\n<p data-start=\"1218\" data-end=\"1273\">No tools or adjustments are required during changeover.<\/p>\n<h3 data-section-id=\"1gfhrmr\" data-start=\"1275\" data-end=\"1311\"><strong>Programming and workflow features<\/strong><\/h3>\n<p data-start=\"1313\" data-end=\"1432\">The Vision G2 Classic 6 includes a full-color touchscreen interface with intuitive menus and programming functionality.<\/p>\n<p data-start=\"1434\" data-end=\"1451\"><strong>Features include:<\/strong><\/p>\n<ul data-start=\"1453\" data-end=\"1718\">\n<li data-section-id=\"jl3u5f\" data-start=\"1453\" data-end=\"1533\">Quick Test function for immediate test initiation with a single button press<\/li>\n<li data-section-id=\"9gw79u\" data-start=\"1534\" data-end=\"1568\">Storage of up to 100 protocols<\/li>\n<li data-section-id=\"yuvzy6\" data-start=\"1569\" data-end=\"1608\">Create, manage, and recall routines<\/li>\n<li data-section-id=\"19n009x\" data-start=\"1609\" data-end=\"1678\">Transfer protocols to other Vision G2 systems using a flash drive<\/li>\n<li data-section-id=\"1fzevsj\" data-start=\"1679\" data-end=\"1718\">Security support for up to 50 users<\/li>\n<\/ul>\n<p data-start=\"1720\" data-end=\"1762\"><strong>The system supports precision control for:<\/strong><\/p>\n<ul data-start=\"1764\" data-end=\"1823\">\n<li data-section-id=\"10yjj52\" data-start=\"1764\" data-end=\"1791\">Speed range: 25\u2013250 rpm<\/li>\n<li data-section-id=\"c9e5xi\" data-start=\"1792\" data-end=\"1823\">Temperature range: 25\u201355 \u00b0C<\/li>\n<\/ul>\n<h3><strong>Features<\/strong><\/h3>\n<div class=\"qMYqUG_convSearchResultHighlightRoot\">\n<div class=\"\" data-turn-id-container=\"request-69d794da-f0b4-832b-b7e1-6f737fb8654b-19\" data-is-intersecting=\"true\">\n<div class=\"relative w-full overflow-visible\">\n<section class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [&amp;:has([data-writing-block])&gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-69d794da-f0b4-832b-b7e1-6f737fb8654b-19\" data-turn-id-container=\"request-69d794da-f0b4-832b-b7e1-6f737fb8654b-19\" data-testid=\"conversation-turn-132\" data-scroll-anchor=\"false\" data-turn=\"assistant\">\n<div class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\">\n<div class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\">\n<div class=\"flex max-w-full flex-col gap-4 grow\">\n<div class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+&amp;]:mt-1\" dir=\"auto\" tabindex=\"0\" data-message-author-role=\"assistant\" data-message-id=\"c7dfe426-176e-43cc-b6b3-ba3362c235e7\" data-message-model-slug=\"gpt-5-5\" data-turn-start-message=\"true\">\n<div class=\"flex w-full flex-col gap-1 empty:hidden\">\n<div class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\">\n<p data-start=\"1857\" data-end=\"2068\">Vision G2 dissolution testers are designed using more than 60 years of dissolution expertise and feature a modular, plug-and-play design. Systems can be upgraded or automated without requiring separate firmware.<\/p>\n<p data-start=\"2070\" data-end=\"2107\"><strong>Additional platform features include:<\/strong><\/p>\n<ul data-start=\"2109\" data-end=\"2712\">\n<li data-section-id=\"codvqi\" data-start=\"2109\" data-end=\"2165\">Customizable reports with user-defined report styles<\/li>\n<li data-section-id=\"efah11\" data-start=\"2166\" data-end=\"2245\">Hand-held digital temperature probe for vessels and water bath measurements<\/li>\n<li data-section-id=\"voheg8\" data-start=\"2246\" data-end=\"2315\">Quick access to internal components without tools for maintenance<\/li>\n<li data-section-id=\"1h99sqy\" data-start=\"2316\" data-end=\"2372\">Maximum spindle speed variation of 0.6 rpm (typical)<\/li>\n<li data-section-id=\"118uudt\" data-start=\"2373\" data-end=\"2457\">Independent Vision\u00ae heater circulator with low vibration and space-saving design<\/li>\n<li data-section-id=\"hko3c1\" data-start=\"2458\" data-end=\"2518\">Molded water bath with rapid heat-up and low-level drain<\/li>\n<li data-section-id=\"bnzvex\" data-start=\"2519\" data-end=\"2552\">Rugged chip-resistant vessels<\/li>\n<li data-section-id=\"1i3gn1a\" data-start=\"2553\" data-end=\"2593\">Numerous user-defined configurations<\/li>\n<li data-section-id=\"1ot950k\" data-start=\"2594\" data-end=\"2654\">User-defined speed and temperature tolerances and alarms<\/li>\n<li data-section-id=\"12tv8gx\" data-start=\"2655\" data-end=\"2712\">Free technical support for the life of the instrument<\/li>\n<\/ul>\n<p data-start=\"2714\" data-end=\"2906\" data-is-last-node=\"\" data-is-only-node=\"\">The Vision G2 Classic 6 combines compact design, flexible configuration options, and programmable operation in a dissolution testing platform designed to simplify routine laboratory workflows.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/div>\n<\/div>\n<\/div>\n<h3><strong>Specifications\u00a0<\/strong><\/h3>\n<div>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\"><strong>Weight<\/strong><\/th>\n<td>Dry<\/td>\n<td>29.5\u202fkg (65\u202flb)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Bath and vessels filled with water<\/td>\n<td>49\u202fkg (108\u202flb)<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\"><strong>Dimensions<\/strong><\/th>\n<td>H \u00d7 W \u00d7 D<\/td>\n<td>67.3 \u00d7 39.4 \u00d7 58.4\u202fcm (26.5 \u00d7 15.5 \u00d7 23.0\u202fin.)<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\"><strong>Bath<\/strong><\/th>\n<td>Capacity<\/td>\n<td>13.3\u202fliters (3.5\u202fgallons) with 6 vessels<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\"><strong>Power<\/strong><\/th>\n<td>Input<\/td>\n<td>24\u202fVDC, 3.75\u202fA, 90\u202fW<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Requirement<\/td>\n<td>External power supply only<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\"><strong>Spindle speed<\/strong><\/th>\n<td>Range<\/td>\n<td>25\u2013250\u202frpm<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Accuracy<\/td>\n<td>\u00b1\u202f1\u202frpm<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Displayed resolution<\/td>\n<td>0.1\u202frpm<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\"><strong>Temperature<\/strong><\/th>\n<td>Programmable range<\/td>\n<td>25.0\u201355.0\u202f\u00b0C<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Accuracy<\/td>\n<td>\u00b1\u202f0.5\u202f\u00b0C<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Control stability<\/td>\n<td>\u00b1\u202f0.1\u202f\u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\"><strong>Digital temperature probes<\/strong><\/th>\n<td>Range<\/td>\n<td>10\u201360\u202f\u00b0C<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Accuracy<\/td>\n<td>\u00b1\u202f0.1\u202f\u00b0C (30\u201355\u202f\u00b0C)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Displayed resolution<\/td>\n<td>0.01\u202f\u00b0C<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Minimum submersion depth<\/td>\n<td>25\u202fmm<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Response time<\/td>\n<td>&lt;\u202f45\u202fseconds (typically ~30\u202fseconds)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3 class=\"main-form-title\"><strong>Find the perfect Dissolution Testing Solution for your needs<\/strong><\/h3>\n<p>Teledyne has developed a <a href=\"https:\/\/dissolution-configurator.teledynehanson.com\/\">online configurator<\/a>\u00a0<span class=\"break-words \"><span dir=\"ltr\">that allows you to design a dissolution system tailored to your exact requirements.<\/span><\/span><\/p>\n<p><span class=\"break-words \"><span dir=\"ltr\">This user-friendly tool makes it easy to build a system that perfectly matches your needs, ensuring maximum efficiency and productivity. From selecting dissolution baths to choosing specialized accessories, the configurator gives you endless possibilities to create your ideal setup.<\/span><\/span><\/p>\n<p><script type=\"application\/ld+json\"> \n{ \n  \"@context\": \"https:\/\/schema.org\/\", \n  \"@type\": \"Product\", \n  \"name\": \"Vision G2 Classic 6\", \n  \"image\": \"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/VisionG2_Classic6-1.png\", \n  \"description\": \"The Vision G2 Classic 6 provides easy access to all vessels while maintaining a compact footprint that helps conserve laboratory bench space. It supports precision control for a speed range ranging from 25-250 rpm and a temperature range of 25-55 \u00b0C.\", \n  \"brand\": { \n    \"@type\": \"Brand\", \n    \"name\": \"Teledyne Labs\" \n  }, \n  \"offers\": { \n    \"@type\": \"Offer\", \n    \"url\": \"https:\/\/chemspx.com\/instruments\/vision-g2-classic-6\/\", \n    \"priceCurrency\": \"EUR\", \n    \"price\": \"0.00\", \n    \"availability\": \"https:\/\/schema.org\/InStock\", \n    \"seller\": { \n      \"@type\": \"Organization\", \n      \"name\": \"ChemSPX\", \n      \"url\": \"https:\/\/chemspx.com\", \n      \"logo\": \"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/Logo_ChemSPX-1.png\", \n      \"areaServed\": [ \n        { \"@type\": \"Country\", \"name\": \"Belgium\" }, \n        { \"@type\": \"Country\", \"name\": \"Netherlands\" }, \n        { \"@type\": \"Country\", \"name\": \"Luxembourg\" } \n      ] \n    } \n  } \n} \n<\/script><\/p>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [{\n    \"@type\": \"Question\",\n    \"name\": \"What is the Vision G2 Classic 6 dissolution tester?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"The Vision\u00ae G2 Classic 6 is a compact and durable dissolution testing system designed for manual workflows. It delivers precise control and user-friendly operation while meeting global regulatory and compliance standards.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"How many vessels does the Vision G2 Classic 6 support?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"The system features a 6-position configuration, allowing simultaneous testing of six samples while maintaining a compact footprint.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"What makes the Vision G2 Classic 6 suitable for small laboratories?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Its compact design reduces bench space requirements while still providing full access to all vessels. This makes it ideal for laboratories where space efficiency is important.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Can the system switch between different USP apparatus?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Yes, the system supports tool-free switching between USP Apparatus 1, 2, 5, and 6, as well as small-volume configurations of 150 mL and 250 mL. No tools or adjustments are required during changeover.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"What are the speed and temperature control ranges?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"The Vision G2 Classic 6 supports a speed range from 25 to 250 rpm and a temperature range from 25 to 55 \u00b0C, providing precise control over test conditions.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Can methods be shared between multiple systems?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Yes, protocols can be transferred to other Vision G2 systems using a flash drive. This supports consistent workflows across different instruments.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Why choose the Vision G2 Classic 6 for dissolution testing?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"The Vision G2 Classic 6 combines compact design, flexible configuration, regulatory compliance, and intuitive operation. It offers a reliable and efficient solution for laboratories performing routine or regulated dissolution testing.\"\n    }\n  }]\n}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Compact and robust dissolution tester<\/p>","protected":false},"featured_media":2581,"template":"","country":[650,649],"brands":[668],"applications":[639,570],"markets":[14,25,24],"class_list":["post-2417","instruments","type-instruments","status-publish","has-post-thumbnail","hentry","country-be","country-nl","brands-teledyne_labs","applications-dissolution-testing","applications-process-control","markets-chemicals","markets-consumer-products","markets-pharmaceuticals"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Vision G2 Classic 6 | Dissolution Tester | ChemSPX<\/title>\n<meta name=\"description\" content=\"The Vision G2 Classic 6 provides easy access to all vessels while maintaining a compact footprint that helps conserve laboratory bench space.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/chemspx.com\/fr\/instruments\/vision-g2-classic-6\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Vision G2 Classic 6 | Dissolution Tester | ChemSPX\" \/>\n<meta property=\"og:description\" content=\"The Vision G2 Classic 6 provides easy access to all vessels while maintaining a compact footprint that helps conserve laboratory bench space.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/chemspx.com\/fr\/instruments\/vision-g2-classic-6\/\" \/>\n<meta property=\"og:site_name\" content=\"ChemSPX\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-18T13:45:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/VisionG2_Classic6-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"400\" \/>\n\t<meta property=\"og:image:height\" content=\"400\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/instruments\\\/vision-g2-classic-6\\\/\",\"url\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/instruments\\\/vision-g2-classic-6\\\/\",\"name\":\"Vision G2 Classic 6 | Dissolution Tester | ChemSPX\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/instruments\\\/vision-g2-classic-6\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/instruments\\\/vision-g2-classic-6\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/VisionG2_Classic6-1.png\",\"datePublished\":\"2025-04-03T13:08:14+00:00\",\"dateModified\":\"2026-05-18T13:45:35+00:00\",\"description\":\"The Vision G2 Classic 6 provides easy access to all vessels while maintaining a compact footprint that helps conserve laboratory bench space.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/instruments\\\/vision-g2-classic-6\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/chemspx.com\\\/fr\\\/instruments\\\/vision-g2-classic-6\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/instruments\\\/vision-g2-classic-6\\\/#primaryimage\",\"url\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/VisionG2_Classic6-1.png\",\"contentUrl\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/VisionG2_Classic6-1.png\",\"width\":400,\"height\":400,\"caption\":\"Compact dissolution tester\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/instruments\\\/vision-g2-classic-6\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/chemspx.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Instruments\",\"item\":\"https:\\\/\\\/chemspx.com\\\/instruments\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Vision G2 Classic 6\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/\",\"name\":\"ChemSPX\",\"description\":\"ChemSPX\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Vision G2 Classic 6 | Dissolution Tester | ChemSPX","description":"The Vision G2 Classic 6 provides easy access to all vessels while maintaining a compact footprint that helps conserve laboratory bench space.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/chemspx.com\/fr\/instruments\/vision-g2-classic-6\/","og_locale":"fr_FR","og_type":"article","og_title":"Vision G2 Classic 6 | Dissolution Tester | ChemSPX","og_description":"The Vision G2 Classic 6 provides easy access to all vessels while maintaining a compact footprint that helps conserve laboratory bench space.","og_url":"https:\/\/chemspx.com\/fr\/instruments\/vision-g2-classic-6\/","og_site_name":"ChemSPX","article_modified_time":"2026-05-18T13:45:35+00:00","og_image":[{"width":400,"height":400,"url":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/VisionG2_Classic6-1.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/chemspx.com\/fr\/instruments\/vision-g2-classic-6\/","url":"https:\/\/chemspx.com\/fr\/instruments\/vision-g2-classic-6\/","name":"Vision G2 Classic 6 | Dissolution Tester | ChemSPX","isPartOf":{"@id":"https:\/\/chemspx.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/chemspx.com\/fr\/instruments\/vision-g2-classic-6\/#primaryimage"},"image":{"@id":"https:\/\/chemspx.com\/fr\/instruments\/vision-g2-classic-6\/#primaryimage"},"thumbnailUrl":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/VisionG2_Classic6-1.png","datePublished":"2025-04-03T13:08:14+00:00","dateModified":"2026-05-18T13:45:35+00:00","description":"The Vision G2 Classic 6 provides easy access to all vessels while maintaining a compact footprint that helps conserve laboratory bench space.","breadcrumb":{"@id":"https:\/\/chemspx.com\/fr\/instruments\/vision-g2-classic-6\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/chemspx.com\/fr\/instruments\/vision-g2-classic-6\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/chemspx.com\/fr\/instruments\/vision-g2-classic-6\/#primaryimage","url":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/VisionG2_Classic6-1.png","contentUrl":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/VisionG2_Classic6-1.png","width":400,"height":400,"caption":"Compact dissolution tester"},{"@type":"BreadcrumbList","@id":"https:\/\/chemspx.com\/fr\/instruments\/vision-g2-classic-6\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/chemspx.com\/"},{"@type":"ListItem","position":2,"name":"Instruments","item":"https:\/\/chemspx.com\/instruments\/"},{"@type":"ListItem","position":3,"name":"Vision G2 Classic 6"}]},{"@type":"WebSite","@id":"https:\/\/chemspx.com\/fr\/#website","url":"https:\/\/chemspx.com\/fr\/","name":"ChemSPX","description":"ChemSPX","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/chemspx.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/instruments\/2417","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/instruments"}],"about":[{"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/types\/instruments"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/media\/2581"}],"wp:attachment":[{"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/media?parent=2417"}],"wp:term":[{"taxonomy":"country","embeddable":true,"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/country?post=2417"},{"taxonomy":"brands","embeddable":true,"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/brands?post=2417"},{"taxonomy":"applications","embeddable":true,"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/applications?post=2417"},{"taxonomy":"markets","embeddable":true,"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/markets?post=2417"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}