{"id":2427,"date":"2023-01-03T15:08:23","date_gmt":"2023-01-03T14:08:23","guid":{"rendered":"https:\/\/chemspx.com\/instruments\/atlas-hd-reaction-calorimeter\/"},"modified":"2026-07-23T09:55:53","modified_gmt":"2026-07-23T07:55:53","slug":"atlas-hd-reaction-calorimeter","status":"publish","type":"instruments","link":"https:\/\/chemspx.com\/fr\/instruments\/atlas-hd-reaction-calorimeter\/","title":{"rendered":"Atlas HD Reaction Calorimeter"},"content":{"rendered":"<h2 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"azsgs2\" data-start=\"33\" data-end=\"75\">Easy-to-use reaction calorimetry system<\/h2>\n<p class=\"\" data-start=\"77\" data-end=\"445\">The Atlas HD Reaction Calorimeter is a high-performance reaction calorimetry system that exists for safe, accurate and straightforward thermal analysis of chemical reactions. The system operates in either <strong>Heat Flow Calorimetry (HFC) or Power Compensation Calorimetry (PCC)<\/strong> mode, allowing users to select the most suitable measurement method for their process.<\/p>\n<p data-start=\"447\" data-end=\"598\">Designed for ease of use, the Atlas HD simplifies experiment setup, automates key procedures and enables rapid generation of power and enthalpy graphs.<\/p>\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"4yh90y\" data-start=\"600\" data-end=\"671\"><strong>Heat Flow Calorimetry (HFC) and Power Compensation Calorimetry (PCC)<\/strong><\/h3>\n<p data-start=\"673\" data-end=\"765\">The system supports two reaction calorimetry methods, each suited to different applications.<\/p>\n<p data-start=\"767\" data-end=\"826\"><strong data-start=\"767\" data-end=\"798\">Heat Flow Calorimetry (HFC)<\/strong> is generally preferred for:<\/p>\n<ul data-start=\"828\" data-end=\"935\">\n<li data-section-id=\"g1ezf6\" data-start=\"828\" data-end=\"886\">Reactions where the heater could influence the chemistry<\/li>\n<li data-section-id=\"sqz3pk\" data-start=\"887\" data-end=\"935\">Processes involving large exothermic reactions<\/li>\n<\/ul>\n<p data-start=\"937\" data-end=\"1024\">During HFC measurements, the dip heater is not used while the reaction is taking place.<\/p>\n<p data-start=\"1026\" data-end=\"1182\"><strong data-start=\"1026\" data-end=\"1066\">Power Compensation Calorimetry (PCC)<\/strong> is typically selected when faster results are required, as it does not require pre- or post-experiment calibration.<\/p>\n<p data-start=\"1184\" data-end=\"1269\">In both operating modes, you can monitor important reaction parameters in real time.<\/p>\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1fazlct\" data-start=\"1271\" data-end=\"1300\"><strong>Automated reaction control<\/strong><\/h3>\n<p data-start=\"1302\" data-end=\"1409\">The Atlas PC Reaction Calorimetry Software guides users through experiment setup using an intuitive wizard.<\/p>\n<p data-start=\"1411\" data-end=\"1453\"><strong>Parameters that can be configured include:<\/strong><\/p>\n<ul data-start=\"1455\" data-end=\"1627\">\n<li data-section-id=\"v7unot\" data-start=\"1455\" data-end=\"1477\">Reaction temperature<\/li>\n<li data-section-id=\"ns3w83\" data-start=\"1478\" data-end=\"1505\">Reagent dosing quantities<\/li>\n<li data-section-id=\"1p2mdeu\" data-start=\"1506\" data-end=\"1595\">Expected power level (for example, moderate endothermic or strong exothermic reactions)<\/li>\n<li data-section-id=\"t62k2m\" data-start=\"1596\" data-end=\"1627\">Alarms and associated actions<\/li>\n<\/ul>\n<p data-start=\"1629\" data-end=\"1729\">Once the experiment starts, the software automatically manages the complete process, including:<\/p>\n<ul data-start=\"1731\" data-end=\"1852\">\n<li data-section-id=\"1xmmzfa\" data-start=\"1731\" data-end=\"1781\">Stabilization at the target reaction temperature<\/li>\n<li data-section-id=\"1e53yj6\" data-start=\"1782\" data-end=\"1800\">Reagent addition<\/li>\n<li data-section-id=\"1dqrpnf\" data-start=\"1801\" data-end=\"1852\">Pre- and post-run calibration for HFC experiments<\/li>\n<\/ul>\n<p data-start=\"1854\" data-end=\"1922\">This automation allows experiments to run without user intervention.<\/p>\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1gwvbpy\" data-start=\"1924\" data-end=\"1953\"><strong>Flexible laboratory system<\/strong><\/h3>\n<p data-start=\"1955\" data-end=\"2128\">The Atlas HD Reaction Calorimeter is compatible with a range of <strong data-start=\"2019\" data-end=\"2066\">vacuum-jacketed reactors from 100 mL to 2 L<\/strong>, providing flexibility for different laboratory applications. When reaction calorimetry is not necessary, you can also use the system as an automated jacketed reactor, allowing it to serve multiple purposes within the laboratory.<\/p>\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1bw3j8i\" data-start=\"2298\" data-end=\"2333\"><strong>Fast data analysis and reporting<\/strong><\/h3>\n<p data-start=\"2335\" data-end=\"2416\">Following each experiment, the Atlas Reporting Software simplifies data analysis.<\/p>\n<p data-start=\"2418\" data-end=\"2445\"><strong>The software automatically:<\/strong><\/p>\n<ul data-start=\"2447\" data-end=\"2578\">\n<li data-section-id=\"1pf1tj1\" data-start=\"2447\" data-end=\"2474\">Includes calibration data<\/li>\n<li data-section-id=\"p0945c\" data-start=\"2475\" data-end=\"2525\">Compensates for the enthalpy of reagent addition<\/li>\n<li data-section-id=\"6vuame\" data-start=\"2526\" data-end=\"2578\">Corrects for deviations from isothermal conditions<\/li>\n<\/ul>\n<p data-start=\"2580\" data-end=\"2707\">Power and enthalpy graphs can then be generated with a single click, making post-experiment analysis quick and straightforward.<\/p>\n<h3 data-section-id=\"1wfz5da\" data-start=\"2709\" data-end=\"2741\"><strong>What is reaction calorimetry?<\/strong><\/h3>\n<p data-start=\"2743\" data-end=\"3084\">Reaction calorimetry is a branch of calorimetry that measures the heat released or absorbed during a chemical reaction. It enables chemists to study the thermal behavior and kinetics of reactions on a laboratory scale while working under realistic process conditions, including controlled stirring, temperature, pressure and reagent dosing.<\/p>\n<p data-start=\"3086\" data-end=\"3275\">By measuring the energy generated or consumed during a reaction, reaction calorimetry supports process understanding and allows failure scenarios to be investigated safely on a small scale.<\/p>\n<h3 data-section-id=\"t4ytit\" data-start=\"3277\" data-end=\"3292\"><strong>Key features<\/strong><\/h3>\n<ul data-start=\"3294\" data-end=\"3902\">\n<li data-section-id=\"ltq8eq\" data-start=\"3294\" data-end=\"3387\">Operates in both Heat Flow Calorimetry (HFC) and Power Compensation Calorimetry (PCC) modes<\/li>\n<li data-section-id=\"7iu1et\" data-start=\"3388\" data-end=\"3435\">Safe and accurate reaction calorimetry system<\/li>\n<li data-section-id=\"1ac7q7z\" data-start=\"3436\" data-end=\"3495\">Simple configuration through an intuitive software wizard<\/li>\n<li data-section-id=\"i8iuby\" data-start=\"3496\" data-end=\"3571\">Automated control of reaction temperature, reagent dosing and calibration<\/li>\n<li data-section-id=\"xm63jw\" data-start=\"3572\" data-end=\"3617\">Real-time monitoring of reaction parameters<\/li>\n<li data-section-id=\"9sf8z5\" data-start=\"3618\" data-end=\"3665\">Rapid generation of power and enthalpy graphs<\/li>\n<li data-section-id=\"k866sn\" data-start=\"3666\" data-end=\"3731\">Compatible with vacuum-jacketed reactors from 100 mL to 2 L<\/li>\n<li data-section-id=\"13fl6xu\" data-start=\"3732\" data-end=\"3809\">Functions as an automated jacketed reactor when calorimetry is not required<\/li>\n<li data-section-id=\"1g9acvz\" data-start=\"3810\" data-end=\"3902\">Atlas Reporting Software provides automatic data correction and one-click graph generation<\/li>\n<\/ul>\n<h3><strong>Technical specifications\u00a0<\/strong><\/h3>\n<div>\n<table>\n<tbody>\n<tr>\n<th><strong>Vessel volume range<\/strong><\/th>\n<td>\u2022 50 mL<br \/>\n\u2022 100 mL<br \/>\n\u2022 250 mL<br \/>\n\u2022 500 mL<br \/>\n\u2022 1 L<br \/>\n\u2022 2 L (DN80)<br \/>\n\u2022 1 L<br \/>\n\u2022 2 L<br \/>\n\u2022 5 L (DN150)<\/td>\n<\/tr>\n<tr>\n<th><strong>Vessel shapes<\/strong><\/th>\n<td>Torispherical, Conical, Round Bottom<\/td>\n<\/tr>\n<tr>\n<th><strong>Vessel profiles<\/strong><\/th>\n<td>Jacketed, Vacuum Jacketed<\/td>\n<\/tr>\n<tr>\n<th><strong>Other vessel types<\/strong><\/th>\n<td>No (Round Bottom Flasks available with regular Atlas base)<\/td>\n<\/tr>\n<tr>\n<th><strong>Temperature range<\/strong><\/th>\n<td>-90\u202f\u00b0C to +250\u202f\u00b0C (with suitable seal kit)<\/td>\n<\/tr>\n<tr>\n<th><strong>Stirring options<\/strong><\/th>\n<td>\u2022 Atlas Scorpion Overhead Stirrer: up to 800 rpm, 11 N\u00b7cm torque<br \/>\n\u2022 Optional Heidolph Stirrer: up to 2000 rpm, 100 N\u00b7cm torque<\/td>\n<\/tr>\n<tr>\n<th><strong>Automation<\/strong><\/th>\n<td>Yes, standard<\/td>\n<\/tr>\n<tr>\n<th><strong>Modes of operation<\/strong><\/th>\n<td>\u2022 Atlas HD touchscreen control<br \/>\n\u2022 Atlas PC software<br \/>\n\u2022 Manual operation<\/td>\n<\/tr>\n<tr>\n<th><strong>Sensor options<\/strong><\/th>\n<td>\u2022 Temperature<br \/>\n\u2022 pH<br \/>\n\u2022 Pressure<br \/>\n\u2022 Turbidity<br \/>\n\u2022 In-situ FTIR<br \/>\n\u2022 Other sensors available<\/td>\n<\/tr>\n<tr>\n<th><strong>Pressure range<\/strong><\/th>\n<td>Vacuum (50 mbar(a)) to +0.25 barg<br \/>\nFor higher pressures up to 3 bar, see Atlas 3 Bar Pressure Systems<\/td>\n<\/tr>\n<tr>\n<th><strong>Reaction calorimetry<\/strong><\/th>\n<td>\u2022 Heat Flow Calorimetry (HFC)<br \/>\n\u2022 Power Compensation Calorimetry (PCC)<\/td>\n<\/tr>\n<tr>\n<th><strong>Reagent addition and sampling<\/strong><\/th>\n<td>\u2022 Manual dosing<br \/>\n\u2022 Automated dosing (volumetric)<br \/>\n\u2022 Automated dosing (gravimetric)<br \/>\n\u2022 Liquid sampling<br \/>\n\u2022 Full gas control<br \/>\n\u2022 Atlas syringe pump range<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [{\n    \"@type\": \"Question\",\n    \"name\": \"What is reaction calorimetry?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Reaction calorimetry is a technique that measures the heat released or absorbed during a chemical reaction. It helps chemists and chemical engineers understand reaction behavior, reaction kinetics, and thermal safety under realistic process conditions.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Why is reaction calorimetry important in process development?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Reaction calorimetry provides information about the energy generated during a reaction. This data helps researchers optimize process conditions, improve efficiency, and evaluate process safety before transferring a reaction to larger production scales.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"What is the difference between Heat Flow Calorimetry and Power Compensation Calorimetry?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Heat Flow Calorimetry measures heat transfer between the reaction and its surroundings and is commonly used for highly exothermic reactions or processes where heater input could influence the chemistry. Power Compensation Calorimetry measures the energy required to maintain temperature and is often selected when faster results are required because no pre- or post-experiment calibration is necessary.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"When should Heat Flow Calorimetry be used?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Heat Flow Calorimetry is typically used for reactions involving significant heat generation and for applications where direct heater input could affect the reaction outcome.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"When should Power Compensation Calorimetry be used?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Power Compensation Calorimetry is often preferred when rapid experimental turnaround is important because calibration before and after the experiment is not required.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Can reaction calorimetry help prevent thermal runaway reactions?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Yes. Reaction calorimetry helps identify conditions that may lead to uncontrolled heat generation. By understanding reaction heat profiles, manufacturers can develop operating limits and emergency procedures that reduce the risk of thermal runaway.\"\n    }\n  }]\n}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Easy-to-use, high-performance calorimeter system<\/p>","protected":false},"featured_media":2591,"template":"","country":[650],"brands":[628],"applications":[587,567,653],"markets":[14,24,23],"class_list":["post-2427","instruments","type-instruments","status-publish","has-post-thumbnail","hentry","country-be","brands-syrris","applications-batch-synthesis-chemistry","applications-chemistry","applications-jacketed-lab-reactors-chemistry","markets-chemicals","markets-pharmaceuticals","markets-specialty-chemicals"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Atlas HD Reaction Calorimeter | ChemSPX<\/title>\n<meta name=\"description\" content=\"The Atlas HD Reaction Calorimeter can operate in either Heat Flow Calorimetry (HFC) or Power Compensation Calorimetry (PCC) mode.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/chemspx.com\/fr\/instruments\/atlas-hd-reaction-calorimeter\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Atlas HD Reaction Calorimeter | ChemSPX\" \/>\n<meta property=\"og:description\" content=\"The Atlas HD Reaction Calorimeter can operate in either Heat Flow Calorimetry (HFC) or Power Compensation Calorimetry (PCC) mode.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/chemspx.com\/fr\/instruments\/atlas-hd-reaction-calorimeter\/\" \/>\n<meta property=\"og:site_name\" content=\"ChemSPX\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-23T07:55:53+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/Syris_AtlasHD.png\" \/>\n\t<meta property=\"og:image:width\" content=\"400\" \/>\n\t<meta property=\"og:image:height\" content=\"400\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/instruments\\\/atlas-hd-reaction-calorimeter\\\/\",\"url\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/instruments\\\/atlas-hd-reaction-calorimeter\\\/\",\"name\":\"Atlas HD Reaction Calorimeter | ChemSPX\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/instruments\\\/atlas-hd-reaction-calorimeter\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/instruments\\\/atlas-hd-reaction-calorimeter\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/Syris_AtlasHD.png\",\"datePublished\":\"2023-01-03T14:08:23+00:00\",\"dateModified\":\"2026-07-23T07:55:53+00:00\",\"description\":\"The Atlas HD Reaction Calorimeter can operate in either Heat Flow Calorimetry (HFC) or Power Compensation Calorimetry (PCC) mode.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/instruments\\\/atlas-hd-reaction-calorimeter\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/chemspx.com\\\/fr\\\/instruments\\\/atlas-hd-reaction-calorimeter\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/instruments\\\/atlas-hd-reaction-calorimeter\\\/#primaryimage\",\"url\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/Syris_AtlasHD.png\",\"contentUrl\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/Syris_AtlasHD.png\",\"width\":400,\"height\":400,\"caption\":\"Atlas HD Reaction Calorimeter\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/instruments\\\/atlas-hd-reaction-calorimeter\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/chemspx.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Instruments\",\"item\":\"https:\\\/\\\/chemspx.com\\\/instruments\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Atlas HD Reaction Calorimeter\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/\",\"name\":\"ChemSPX\",\"description\":\"ChemSPX\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Atlas HD Reaction Calorimeter | ChemSPX","description":"The Atlas HD Reaction Calorimeter can operate in either Heat Flow Calorimetry (HFC) or Power Compensation Calorimetry (PCC) mode.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/chemspx.com\/fr\/instruments\/atlas-hd-reaction-calorimeter\/","og_locale":"fr_FR","og_type":"article","og_title":"Atlas HD Reaction Calorimeter | ChemSPX","og_description":"The Atlas HD Reaction Calorimeter can operate in either Heat Flow Calorimetry (HFC) or Power Compensation Calorimetry (PCC) mode.","og_url":"https:\/\/chemspx.com\/fr\/instruments\/atlas-hd-reaction-calorimeter\/","og_site_name":"ChemSPX","article_modified_time":"2026-07-23T07:55:53+00:00","og_image":[{"width":400,"height":400,"url":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/Syris_AtlasHD.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/chemspx.com\/fr\/instruments\/atlas-hd-reaction-calorimeter\/","url":"https:\/\/chemspx.com\/fr\/instruments\/atlas-hd-reaction-calorimeter\/","name":"Atlas HD Reaction Calorimeter | ChemSPX","isPartOf":{"@id":"https:\/\/chemspx.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/chemspx.com\/fr\/instruments\/atlas-hd-reaction-calorimeter\/#primaryimage"},"image":{"@id":"https:\/\/chemspx.com\/fr\/instruments\/atlas-hd-reaction-calorimeter\/#primaryimage"},"thumbnailUrl":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/Syris_AtlasHD.png","datePublished":"2023-01-03T14:08:23+00:00","dateModified":"2026-07-23T07:55:53+00:00","description":"The Atlas HD Reaction Calorimeter can operate in either Heat Flow Calorimetry (HFC) or Power Compensation Calorimetry (PCC) mode.","breadcrumb":{"@id":"https:\/\/chemspx.com\/fr\/instruments\/atlas-hd-reaction-calorimeter\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/chemspx.com\/fr\/instruments\/atlas-hd-reaction-calorimeter\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/chemspx.com\/fr\/instruments\/atlas-hd-reaction-calorimeter\/#primaryimage","url":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/Syris_AtlasHD.png","contentUrl":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/Syris_AtlasHD.png","width":400,"height":400,"caption":"Atlas HD Reaction Calorimeter"},{"@type":"BreadcrumbList","@id":"https:\/\/chemspx.com\/fr\/instruments\/atlas-hd-reaction-calorimeter\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/chemspx.com\/"},{"@type":"ListItem","position":2,"name":"Instruments","item":"https:\/\/chemspx.com\/instruments\/"},{"@type":"ListItem","position":3,"name":"Atlas HD Reaction Calorimeter"}]},{"@type":"WebSite","@id":"https:\/\/chemspx.com\/fr\/#website","url":"https:\/\/chemspx.com\/fr\/","name":"ChemSPX","description":"ChemSPX","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/chemspx.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/instruments\/2427","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/instruments"}],"about":[{"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/types\/instruments"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/media\/2591"}],"wp:attachment":[{"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/media?parent=2427"}],"wp:term":[{"taxonomy":"country","embeddable":true,"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/country?post=2427"},{"taxonomy":"brands","embeddable":true,"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/brands?post=2427"},{"taxonomy":"applications","embeddable":true,"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/applications?post=2427"},{"taxonomy":"markets","embeddable":true,"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/markets?post=2427"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}