{"id":2427,"date":"2023-01-03T15:08:23","date_gmt":"2023-01-03T14:08:23","guid":{"rendered":"https:\/\/chemspx.com\/instruments\/atlas-hd-reaction-calorimeter\/"},"modified":"2023-02-17T13:53:27","modified_gmt":"2023-02-17T12:53:27","slug":"atlas-hd-reaction-calorimeter","status":"publish","type":"instruments","link":"https:\/\/chemspx.com\/fr\/instruments\/atlas-hd-reaction-calorimeter\/","title":{"rendered":"Atlas HD Reaction Calorimeter"},"content":{"rendered":"
The Atlas HD Reaction Calorimeter operates in either Heat Flow Calorimetry (HFC) or Power Compensation Calorimetry (PCC) mode.<\/p>\n
The system is designed for ease of use with the generation of power and enthalpy graphs made simple and quick. This, combined with the simple configuration of reaction temperatures, dosing quantities, and alarms provides you with a safe and accurate reaction calorimetry system and offers great value for Calorimetry chemists.<\/p>\n
The system offers two modes; Heat Flow Calorimetry (HFC) or Power Compensation Calorimetry (PCC), allowing you to choose which mode is suitable for your process.<\/p>\n
HFC<\/strong> is generally used for reactions where the heater may have an effect on the chemistry since the dip in heater is not used during the reaction. HFC is also preferred when large exotherms are expected.<\/p>\n PCC<\/strong> is used where quicker results are required, since no pre- and post-calibration is required. All important reaction parameters can be monitored in real-time using the Atlas HD Calorimeter.<\/p>\n The Atlas PC Reaction Calorimetry Software offers truly easy reaction calorimetry operation. Configuration of parameters such as reaction temperature, dosing quantities, expected power level (e.g. moderate endotherm; strong exotherm), and alarms (with subsequent actions) are defined in an easy-to-use wizard. \u00a0Everything is controlled automatically during the experiment including stabilization at desired reaction temperature, reagent addition, and in the case of HFC, pre-and\/or post-run calibration. No user intervention is required during the entire process.<\/p>\n The Atlas HD Reaction Calorimeter is destined to be a very popular addition to your laboratory. \u00a0Easy to set and configure, reaction calorimetry cannot be made simpler. \u00a0A wide range of vacuum jacketed reactors from 100 mL to 2 L<\/strong> and the ability to perform HFC or PCC gives you choice. \u00a0When there are no reaction calorimetry experiments to perform, the system will operate seamlessly as an automated jacketed reactor.<\/p>\n The software automatically includes the calibration, compensates for the enthalpy of addition and deviations from isothermal conditions. Post experiment analysis is made easy by the Atlas Reporting Software featuring \u201csingle click\u201d plotting of power and enthalpy.<\/p>\n","protected":false},"excerpt":{"rendered":" Easy-to-use, high-performance calorimeter system<\/p>\n","protected":false},"featured_media":2591,"template":"","country":[650],"brands":[628],"applications":[587,567,653],"markets":[14,24,23],"acf":[],"yoast_head":"\nPowerful automation<\/strong><\/h4>\n
Flexible<\/strong><\/h4>\n
Quick and easy data analysis<\/strong><\/h4>\n