{"id":3992,"date":"2023-11-06T12:11:46","date_gmt":"2023-11-06T11:11:46","guid":{"rendered":"https:\/\/chemspx.com\/?post_type=instruments&p=3992"},"modified":"2024-08-13T14:32:24","modified_gmt":"2024-08-13T13:32:24","slug":"elab-tff-single-use","status":"publish","type":"instruments","link":"https:\/\/chemspx.com\/fr\/instruments\/elab-tff-single-use\/","title":{"rendered":"eLAB TFF Single-use"},"content":{"rendered":"

Leading laboratory single use filtration (TFF SU) technology for downstream processes<\/h2>\n
\n
\n
\n

Engineered to meet the rigorous demands of biotechnological downstream processes, the eLAB\u00ae Tangential Flow Filtration Single-Use fully automatic systems stand out with a remarkable single-use filtration performance<\/b> and ensures unparalleled throughput and efficiency during continuous operation.<\/b> Furthermore, the Single-Use feature of the eLAB\u00ae\u00a0TFF SU adds a layer of sterility and exceptional convenience<\/b>, making it an ideal solution for applications where purity and contamination prevention are paramount. The equipment comprises two main modules:<\/p>\n

The first is the single-use filtration assembly, which includes a single-use tank with a volume ranging from 2 to 10 liters<\/b>, housing the product to be filtered, and a filtration membrane with a surface area spanning from 0.1 to 0.7 m\u00b2<\/b>. The bag,\u00a0designed and manufactured in our ISO7 Clean Room<\/a> facilities,\u00a0is held in place by a load cell and incorporates a conical bottom to minimize the risk of product losses. This plastic tank is firmly secured with a fixed support and includes the tangential filter for biomolecule purification. Both the filter and the support undergo pre-gamma irradiation to meet rigorous quality standards.<\/p>\n

The equipment is seamlessly complemented by the TECNIC tower, equipped with a touchscreen interface, indrustrial PLC, and the eSCADA<\/b>\u00ae\u00a0software<\/b>, facilitating equipment interconnection, data traceability, and comprehensive process control. The tower incorporates two peristaltic addition pumps, a USB port for streamlined data extraction, and a LED status indicator for monitoring the equipment’s operational state.<\/p>\n

Improve your bioprocessing capabilities with the precision, sterility and innovation of the eLAB\u00ae TFF SU system, essential for biotechnology laboratories seeking a simple and safe method to maintain sterility and prevent product contamination.<\/p>\n<\/div>\n<\/div>\n<\/div>\n

 <\/p>\n

Some key features:<\/h3>\n
    \n
  • Maximum hygiene and convenience
    \n<\/strong>While other systems require extensive cleaning and sterilization, the eLAB\u00ae TFF SU is designed for single-use, eliminating the need for complex cleaning processes. This significantly reduces the risk of cross-contamination and increases operational efficiency, especially in applications where sterility and purity are paramount.
    \n<\/strong><\/li>\n
  • Advanced control and automation<\/strong>
    \nEquipped with an advanced control system and automation capabilities, the eLAB\u00ae Tangential Flow Filtration Single-Use allows for more accurate and automated management of filtration processes. This capability to automate complex tasks reduces human error and enhances overall process efficiency and reproducibility.<\/li>\n
  • 4-piston diaphramg pump for precise recirculation<\/strong>
    \nUnlike systems with less adjustable pumps, the eLAB\u00ae TFF SU incorporates an advanced four-piston diaphragm pump, allowing for precise flow control and steady recirculation, a crucial step for maintaining the integrity of sensitive samples and optimizing single-use filtration efficiency.<\/li>\n
  • Broad membrane surface in a compact design<\/strong>
    \nThe eLAB\u00ae TFF SU provides up to 0.7 m\u00b2 of membrane surface area, enabling efficient filtration within a compact footprint, which makes it ideal for laboratories with limited space, facilitating installation and handling without compromising processing capacity.<\/li>\n<\/ul>\n
    \n
    \n

    eLAB TFF SU Configuration<\/h3>\n<\/div>\n<\/div>\n
    \n
    \n
    \n

    The TFF SU system incorporates two distinct yet complementary single-use filtration technologies: membrane cassettes and hollow fibers<\/strong>. Both undergo pre-gamma irradiation to meet rigorous quality standards and are designed to offer high-performance single-use filtration solutions catering to various bioprocessing needs.<\/p>\n

    The eLAB\u00ae Tangential Flow Filtration Single-Use\u2019s membrane cassette<\/strong> technology features a surface area ranging from 0.1 to 0.5 square meters<\/strong>. This technology utilizes flat-sheet membranes arranged in a layered cassette format, providing an extensive area for filtration within a compact space. The cassettes are specifically engineered for precise separation and concentration tasks, making them ideal for applications that demand high purity and efficiency. The large surface area of the membrane cassette ensures effective processing, leading to increased yield and quality of the end product.<\/p>\n

    In contrast, the hollow-fiber<\/strong> technology in the eLAB\u00ae TFF SU offers a membrane area of 0.1 to 0.4 square meters<\/strong>. This technology features thin, hollow strands of membrane material, tightly packed to form a dense bundle. These fibers provide an expansive surface area within a minimal footprint, making them particularly effective for high-throughput applications. The unique structure of the hollow fibers facilitates efficient separation and is well-suited for processes that require high flow rates and effective solute retention.<\/p>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"

    Maximize research & production results with solutions for tough downstream<\/p>\n","protected":false},"featured_media":4514,"template":"","country":[650,649],"brands":[659],"applications":[570,661],"markets":[24],"acf":[],"yoast_head":"\neLAB TFF Single-use - ChemSPX<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/chemspx.com\/fr\/instruments\/elab-tff-single-use\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"eLAB TFF Single-use - ChemSPX\" \/>\n<meta property=\"og:description\" content=\"Maximize research & production results with solutions for tough downstream\" \/>\n<meta property=\"og:url\" content=\"https:\/\/chemspx.com\/fr\/instruments\/elab-tff-single-use\/\" \/>\n<meta property=\"og:site_name\" content=\"ChemSPX\" \/>\n<meta property=\"article:modified_time\" content=\"2024-08-13T13:32:24+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/11\/elab-tff-su-web.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"1000\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/chemspx.com\/fr\/instruments\/elab-tff-single-use\/\",\"url\":\"https:\/\/chemspx.com\/fr\/instruments\/elab-tff-single-use\/\",\"name\":\"eLAB TFF Single-use - ChemSPX\",\"isPartOf\":{\"@id\":\"https:\/\/chemspx.com\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/chemspx.com\/fr\/instruments\/elab-tff-single-use\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/chemspx.com\/fr\/instruments\/elab-tff-single-use\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/11\/elab-tff-su-web.png\",\"datePublished\":\"2023-11-06T11:11:46+00:00\",\"dateModified\":\"2024-08-13T13:32:24+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/chemspx.com\/fr\/instruments\/elab-tff-single-use\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/chemspx.com\/fr\/instruments\/elab-tff-single-use\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/chemspx.com\/fr\/instruments\/elab-tff-single-use\/#primaryimage\",\"url\":\"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/11\/elab-tff-su-web.png\",\"contentUrl\":\"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/11\/elab-tff-su-web.png\",\"width\":1000,\"height\":1000},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/chemspx.com\/fr\/instruments\/elab-tff-single-use\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/chemspx.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Instruments\",\"item\":\"https:\/\/chemspx.com\/instruments\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"eLAB TFF Single-use\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/chemspx.com\/fr\/#website\",\"url\":\"https:\/\/chemspx.com\/fr\/\",\"name\":\"ChemSPX\",\"description\":\"ChemSPX\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/chemspx.com\/fr\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"eLAB TFF Single-use - ChemSPX","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/chemspx.com\/fr\/instruments\/elab-tff-single-use\/","og_locale":"fr_FR","og_type":"article","og_title":"eLAB TFF Single-use - ChemSPX","og_description":"Maximize research & production results with solutions for tough downstream","og_url":"https:\/\/chemspx.com\/fr\/instruments\/elab-tff-single-use\/","og_site_name":"ChemSPX","article_modified_time":"2024-08-13T13:32:24+00:00","og_image":[{"width":1000,"height":1000,"url":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/11\/elab-tff-su-web.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/chemspx.com\/fr\/instruments\/elab-tff-single-use\/","url":"https:\/\/chemspx.com\/fr\/instruments\/elab-tff-single-use\/","name":"eLAB TFF Single-use - ChemSPX","isPartOf":{"@id":"https:\/\/chemspx.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/chemspx.com\/fr\/instruments\/elab-tff-single-use\/#primaryimage"},"image":{"@id":"https:\/\/chemspx.com\/fr\/instruments\/elab-tff-single-use\/#primaryimage"},"thumbnailUrl":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/11\/elab-tff-su-web.png","datePublished":"2023-11-06T11:11:46+00:00","dateModified":"2024-08-13T13:32:24+00:00","breadcrumb":{"@id":"https:\/\/chemspx.com\/fr\/instruments\/elab-tff-single-use\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/chemspx.com\/fr\/instruments\/elab-tff-single-use\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/chemspx.com\/fr\/instruments\/elab-tff-single-use\/#primaryimage","url":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/11\/elab-tff-su-web.png","contentUrl":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/11\/elab-tff-su-web.png","width":1000,"height":1000},{"@type":"BreadcrumbList","@id":"https:\/\/chemspx.com\/fr\/instruments\/elab-tff-single-use\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/chemspx.com\/"},{"@type":"ListItem","position":2,"name":"Instruments","item":"https:\/\/chemspx.com\/instruments\/"},{"@type":"ListItem","position":3,"name":"eLAB TFF Single-use"}]},{"@type":"WebSite","@id":"https:\/\/chemspx.com\/fr\/#website","url":"https:\/\/chemspx.com\/fr\/","name":"ChemSPX","description":"ChemSPX","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/chemspx.com\/fr\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/instruments\/3992"}],"collection":[{"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/instruments"}],"about":[{"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/types\/instruments"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/media\/4514"}],"wp:attachment":[{"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/media?parent=3992"}],"wp:term":[{"taxonomy":"country","embeddable":true,"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/country?post=3992"},{"taxonomy":"brands","embeddable":true,"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/brands?post=3992"},{"taxonomy":"applications","embeddable":true,"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/applications?post=3992"},{"taxonomy":"markets","embeddable":true,"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/markets?post=3992"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}