{"id":8123,"date":"2026-10-31T08:00:00","date_gmt":"2026-10-31T06:00:00","guid":{"rendered":"https:\/\/chemspx.com\/?p=8123"},"modified":"2026-10-13T10:28:18","modified_gmt":"2026-10-13T08:28:18","slug":"why-can-tablet-dissolution-change-during-manufacturing-scale-up","status":"publish","type":"wiki_post","link":"https:\/\/chemspx.com\/fr\/wiki\/why-can-tablet-dissolution-change-during-manufacturing-scale-up\/","title":{"rendered":"Why can tablet dissolution change during manufacturing scale-up?"},"content":{"rendered":"<p>Tablet dissolution changes during manufacturing scale-up because larger batch sizes introduce new mechanical forces, altered mixing dynamics, and different equipment geometries that directly affect how a tablet&#8217;s internal structure forms. These physical changes modify how quickly and completely a drug substance releases from the dosage form. The sections below unpack the specific mechanisms behind each source of variability.<\/p>\n<h2>What factors in manufacturing scale-up affect tablet dissolution?<\/h2>\n<p>The primary factors that affect tablet dissolution during manufacturing scale-up are changes in granule properties, compaction force distribution, blend homogeneity, and equipment-specific process parameters. When a formulation moves from laboratory to pilot or commercial scale, each of these variables shifts in ways that are difficult to predict from small-scale data alone.<\/p>\n<p>At the laboratory scale, process conditions are highly controlled and the batch is small enough that minor inconsistencies average out. At production scale, those same inconsistencies can amplify. The key factors to monitor include:<\/p>\n<ul>\n <li><strong>Granule size distribution<\/strong>: larger granulators produce different shear and moisture gradients, altering particle architecture<\/li>\n <li><strong>Blend uniformity<\/strong>: longer mixing times or higher fill volumes can lead to segregation of active ingredients or excipients<\/li>\n <li><strong>Compaction pressure profiles<\/strong>: high-speed tablet presses apply force differently across a punch array compared to single-station lab presses<\/li>\n <li><strong>Temperature and humidity exposure<\/strong>: longer processing times at scale increase the material&#8217;s exposure to environmental variation<\/li>\n <li><strong>Lubricant over-blending<\/strong>: magnesium stearate and similar lubricants are shear-sensitive and can coat granule surfaces more extensively in large-scale blenders, reducing wettability<\/li>\n<\/ul>\n<p>Each of these factors feeds directly into the dissolution profile observed in downstream testing, making early identification of scale-sensitive parameters critical for pharmaceutical research and development teams in the Benelux and beyond.<\/p>\n<h2>How does granulation scale-up change drug release behavior?<\/h2>\n<p>Granulation scale-up changes drug release behavior by altering granule density, porosity, and internal surface area. These structural properties govern how quickly water penetrates the tablet matrix and how efficiently the active substance dissolves. Granules produced at larger scale are often denser or more irregular, which slows disintegration and reduces dissolution rates compared to lab-scale batches.<\/p>\n<p>In wet granulation, the impeller and chopper speeds, bowl geometry, and liquid addition rate all interact differently at larger volumes. A high-shear granulator operating at commercial scale generates different shear forces per unit mass than a lab-scale equivalent, even when tip speed is matched. This results in granules with different internal porosity and binder distribution.<\/p>\n<p>In fluid bed granulation, the airflow distribution and spray nozzle coverage change with scale, creating zones of over-wetted or under-wetted granules. These inconsistencies translate directly into tablets with variable pore structures, which in turn produce variable dissolution curves. For research teams developing solid oral dosage forms, understanding the mechanism of granule formation at each scale is as important as the final dissolution result itself.<\/p>\n<h2>Why does tablet compaction at scale alter dissolution profiles?<\/h2>\n<p>Tablet compaction at scale alters dissolution profiles because high-speed rotary presses apply compaction forces at much shorter dwell times than laboratory presses, producing tablets with different porosity and internal bonding structures. A tablet compressed in milliseconds at production speed will have a different pore network than one compressed slowly at bench scale, even if the applied force appears equivalent.<\/p>\n<p>Dwell time is the period during which the punch faces maintain peak pressure on the powder bed. At higher press speeds, this window narrows significantly. Materials that are viscoelastic or time-dependent in their compaction behavior will respond differently under short dwell times, producing harder tablets with reduced internal porosity. Reduced porosity means less surface area for water ingress, which slows dissolution.<\/p>\n<p>Conversely, some formulations become more friable at scale if the compaction force distribution across a multi-punch turret is uneven. Tablets from outer punch positions may receive slightly different forces than those from inner positions, creating within-batch dissolution variability that would not appear in a single-punch lab study. Monitoring compaction profiles across all punch positions is therefore an important quality checkpoint during scale-up.<\/p>\n<h2>What role does equipment geometry play in dissolution variability?<\/h2>\n<p>Equipment geometry plays a significant role in dissolution variability because the physical dimensions of mixers, granulators, and tablet presses determine flow patterns, shear gradients, and force distributions that directly shape the tablet&#8217;s microstructure. Two pieces of equipment with the same nominal capacity but different geometries can produce tablets with measurably different dissolution behavior from the same formulation.<\/p>\n<p>In blending, the ratio of fill volume to the blender&#8217;s total volume, the angle of the vessel, and the position of intensifier bars all influence how powders move and whether segregation occurs. In granulation, bowl aspect ratio and impeller blade design affect the shear field experienced by the wet mass. In tablet pressing, the turret diameter and punch count affect how uniformly force is distributed across a production run.<\/p>\n<p>When a formulation is transferred between sites or when equipment is upgraded, geometry differences are a common but underappreciated source of dissolution shift. Pharmaceutical research groups working across Benelux facilities should document equipment geometry parameters as thoroughly as process parameters, since a change in one without a change in the other can produce unexpected dissolution outcomes.<\/p>\n<h2>How can dissolution testing detect scale-up problems early?<\/h2>\n<p>Dissolution testing can detect scale-up problems early by revealing shifts in drug release rate, profile shape, or variability that correlate with specific process changes. When dissolution profiles from scale-up batches are compared systematically against the reference lab-scale profile, deviations signal which process variables have drifted outside acceptable ranges before the product reaches later development stages.<\/p>\n<p>Effective early detection relies on a structured testing approach:<\/p>\n<ol>\n <li><strong>Establish a reference dissolution profile<\/strong> from the validated lab-scale batch, including the full time course, not just a single time point<\/li>\n <li><strong>Test intermediate-scale batches<\/strong> at pilot scale to identify whether shifts are linear or threshold-based as batch size increases<\/li>\n <li><strong>Apply profile comparison metrics<\/strong> such as the f2 similarity factor to quantify whether differences are statistically and practically meaningful<\/li>\n <li><strong>Test under biorelevant conditions<\/strong> where appropriate, using media that reflect the intended research application to understand the real-world significance of any observed shift<\/li>\n <li><strong>Correlate dissolution results with process data<\/strong> (granule size distribution, compaction force logs, and blend time records) to pinpoint the root cause of any change<\/li>\n<\/ol>\n<p>Dissolution testing instruments capable of precise media control, consistent hydrodynamics, and reliable data capture are essential for this kind of comparative work. The quality of the dissolution data is only as good as the instrument generating it.<\/p>\n<h2>When should a formulation be redesigned versus the process adjusted?<\/h2>\n<p>A formulation should be redesigned when the dissolution problem is rooted in the physicochemical properties of the active substance or excipient system, and the process cannot compensate for those limitations at scale. The process should be adjusted when the dissolution shift is caused by a controllable parameter, such as compaction force, granulation end-point, or blending time, that can be brought back within range without changing the composition.<\/p>\n<p>The distinction matters because process adjustments are faster, lower-risk, and require less regulatory documentation than formulation changes. However, chasing a dissolution problem through process adjustments when the root cause is formulation-based leads to a fragile, over-optimized process that is difficult to transfer or reproduce.<\/p>\n<p>Signs that a formulation redesign is warranted include persistent dissolution failure across multiple process conditions, sensitivity to minor excipient lot-to-lot variation, or a fundamental incompatibility between the active substance&#8217;s solubility characteristics and the chosen matrix type. Signs that a process adjustment is sufficient include dissolution shifts that correlate cleanly with a single process variable and that return to specification when that variable is corrected.<\/p>\n<p>For research teams navigating this decision, a structured design of experiments approach at intermediate scale provides the most reliable basis for distinguishing formulation effects from process effects.<\/p>\n<h2>How ChemSPX supports dissolution testing during scale-up<\/h2>\n<p>Reliable dissolution data is only achievable with instrumentation that performs consistently across every batch and every scale. ChemSPX supplies high-end dissolution testing instruments and related laboratory equipment to pharmaceutical research and development laboratories throughout the Benelux region. The team of Sales Engineers and Product Specialists works directly with researchers and lab managers to match the right instrument to the specific testing requirements of scale-up studies.<\/p>\n<p>ChemSPX&#8217;s support in this area includes:<\/p>\n<ul>\n <li>Expert advice on instrument selection for dissolution and related analytical workflows<\/li>\n <li>Application-level support to help teams configure testing methods appropriate for scale-up comparisons<\/li>\n <li>IQ\/OQ installation and validation services to ensure instruments meet GMP and GLP requirements in regulated research environments<\/li>\n <li>Ongoing service and calibration to maintain instrument performance and data integrity over time<\/li>\n<\/ul>\n<p>If your team is working through scale-up challenges and needs reliable dissolution testing instrumentation, <a href=\"https:\/\/chemspx.com\/fr\/contact\/\">contact ChemSPX<\/a> to speak with a specialist.<\/p>\n<div class=\"wp-block-seoaic-faq-block\">\n    <h2 class=\"seoaic-faq-section-title\">Foire aux questions<\/h2>\n            <div class=\"seoaic-faq-item\">\n            <h3 class=\"seoaic-question\">\n                What is the f2 similarity factor and how do I interpret it during scale-up dissolution comparisons?            <\/h3>\n            <p class=\"seoaic-answer\">\n                The f2 similarity factor is a logarithmic transformation of the sum of squared differences between two dissolution profiles, with values ranging from 0 to 100. A value of 50 or above is generally accepted by regulatory agencies (including the EMA) as evidence that two profiles are similar. During scale-up, if your f2 value falls below 50 when comparing a pilot or commercial batch against your lab-scale reference, this signals a meaningful dissolution shift that warrants investigation into specific process variables such as compaction force, granule size distribution, or blending time.            <\/p>\n        <\/div>\n                <div class=\"seoaic-faq-item\">\n            <h3 class=\"seoaic-question\">\n                How do I know which process parameters are most scale-sensitive for my specific formulation?            <\/h3>\n            <p class=\"seoaic-answer\">\n                The most reliable way to identify scale-sensitive parameters is to conduct a risk assessment using prior knowledge of your active substance&#8217;s physicochemical properties combined with a structured Design of Experiments (DoE) at intermediate scale. Parameters such as granulation end-point, lubricant blending time, and compaction dwell time are commonly scale-sensitive, but their relative impact varies by formulation. Mapping dissolution outcomes against individual process variables at pilot scale gives you a data-driven basis for prioritizing which parameters to control most tightly as you move to commercial scale.            <\/p>\n        <\/div>\n                <div class=\"seoaic-faq-item\">\n            <h3 class=\"seoaic-question\">\n                Can lubricant over-blending at scale be corrected without redesigning the formulation?            <\/h3>\n            <p class=\"seoaic-answer\">\n                In most cases, yes \u2014 lubricant over-blending is a process-level problem that can be corrected through process adjustment rather than formulation redesign. Practical corrective actions include reducing blending time, lowering blender fill level, switching to a lower-shear blending configuration, or reducing the lubricant concentration slightly if the specification permits. However, if your formulation is inherently sensitive to minor variations in lubricant coating \u2014 for example, because the active substance has poor intrinsic wettability \u2014 a formulation-level solution such as adding a wetting agent may ultimately be more robust than relying solely on tight process control.            <\/p>\n        <\/div>\n                <div class=\"seoaic-faq-item\">\n            <h3 class=\"seoaic-question\">\n                What is the best way to get started with scale-up dissolution testing if our lab currently only has single-point dissolution data?            <\/h3>\n            <p class=\"seoaic-answer\">\n                The first step is to generate a full dissolution time-course profile from your existing lab-scale batch, ideally across multiple time points that capture the complete release curve from early dissolution through plateau. Single-point data is insufficient for profile comparison because it cannot reveal differences in release rate or profile shape. Once you have a complete reference profile, you can use it as a baseline against which all subsequent scale batches are compared using metrics like the f2 factor. If your current dissolution instrument lacks the precision or media control needed for reliable multi-point profiling, this is also the right moment to evaluate whether your instrumentation is fit for purpose for scale-up comparative work.            <\/p>\n        <\/div>\n                <div class=\"seoaic-faq-item\">\n            <h3 class=\"seoaic-question\">\n                How should we handle dissolution variability that appears within a single commercial-scale batch rather than between batches?            <\/h3>\n            <p class=\"seoaic-answer\">\n                Within-batch dissolution variability at commercial scale most commonly points to either non-uniform compaction force distribution across the tablet press turret or blend segregation occurring during hopper feeding. The diagnostic approach is to sample tablets systematically from different press positions and time points throughout the run, then correlate dissolution results with compaction force logs for each punch position. If variability tracks with punch position, the root cause is mechanical and should be addressed through press maintenance or force calibration. If variability is random across positions, blend homogeneity or feeding consistency is the more likely culprit.            <\/p>\n        <\/div>\n                <div class=\"seoaic-faq-item\">\n            <h3 class=\"seoaic-question\">\n                Are there specific dissolution media or conditions that are better suited for detecting scale-up-related changes?            <\/h3>\n            <p class=\"seoaic-answer\">\n                Biorelevant dissolution media \u2014 such as FaSSIF (Fasted State Simulated Intestinal Fluid) or FeSSIF (Fed State Simulated Intestinal Fluid) \u2014 are generally more discriminating than simple buffer systems and are better at revealing dissolution differences that have real-world significance for the intended application. For research purposes, running dissolution testing in both a standard compendial medium and a biorelevant medium in parallel gives you two complementary data sets: one for regulatory comparability and one for understanding the practical magnitude of any scale-up-related shift. The choice of apparatus (USP 1 basket vs. USP 2 paddle) and hydrodynamic conditions should also be validated to ensure they are discriminating enough to detect the specific changes your formulation is prone to.            <\/p>\n        <\/div>\n                <div class=\"seoaic-faq-item\">\n            <h3 class=\"seoaic-question\">\n                What documentation should we maintain during scale-up to support dissolution troubleshooting later?            <\/h3>\n            <p class=\"seoaic-answer\">\n                Thorough documentation during scale-up should capture not only the standard batch records but also equipment geometry parameters (blender fill ratio, impeller blade design, turret punch count and diameter), full compaction force profiles across all punch positions, granule size distribution data at each scale, lubricant blending time and sequence, and environmental conditions (temperature and relative humidity) throughout processing. When a dissolution problem surfaces \u2014 which is often weeks or months after the batch is manufactured \u2014 this granular process data is what makes root cause analysis tractable. Treating equipment geometry as a documented process parameter, rather than a fixed background variable, is a practice that pays significant dividends during troubleshooting and site transfer activities.            <\/p>\n        <\/div>\n        <\/div>","protected":false},"template":"","class_list":["post-8123","wiki_post","type-wiki_post","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Why can tablet dissolution change during manufacturing scale-up? | ChemSPX<\/title>\n<meta name=\"description\" content=\"Tablet dissolution changes during manufacturing scale-up due to granulation, compaction, and equipment geometry shifts. Learn what to monitor and fix.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/chemspx.com\/fr\/wiki\/why-can-tablet-dissolution-change-during-manufacturing-scale-up\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Why can tablet dissolution change during manufacturing scale-up? | ChemSPX\" \/>\n<meta property=\"og:description\" content=\"Tablet dissolution changes during manufacturing scale-up due to granulation, compaction, and equipment geometry shifts. Learn what to monitor and fix.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/chemspx.com\/fr\/wiki\/why-can-tablet-dissolution-change-during-manufacturing-scale-up\/\" \/>\n<meta property=\"og:site_name\" content=\"ChemSPX\" \/>\n<meta property=\"og:image\" content=\"https:\/\/chemspx.com\/wp-content\/uploads\/2026\/10\/pharmaceutical-tablet-dissolving-lab-beaker.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"768\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"11 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/wiki\\\/why-can-tablet-dissolution-change-during-manufacturing-scale-up\\\/\",\"url\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/wiki\\\/why-can-tablet-dissolution-change-during-manufacturing-scale-up\\\/\",\"name\":\"Why can tablet dissolution change during manufacturing scale-up? | ChemSPX\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/wiki\\\/why-can-tablet-dissolution-change-during-manufacturing-scale-up\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/wiki\\\/why-can-tablet-dissolution-change-during-manufacturing-scale-up\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/pharmaceutical-tablet-dissolving-lab-beaker.webp\",\"datePublished\":\"2026-10-31T06:00:00+00:00\",\"description\":\"Tablet dissolution changes during manufacturing scale-up due to granulation, compaction, and equipment geometry shifts. Learn what to monitor and fix.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/wiki\\\/why-can-tablet-dissolution-change-during-manufacturing-scale-up\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/chemspx.com\\\/fr\\\/wiki\\\/why-can-tablet-dissolution-change-during-manufacturing-scale-up\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/wiki\\\/why-can-tablet-dissolution-change-during-manufacturing-scale-up\\\/#primaryimage\",\"url\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/pharmaceutical-tablet-dissolving-lab-beaker.webp\",\"contentUrl\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/pharmaceutical-tablet-dissolving-lab-beaker.webp\",\"width\":1024,\"height\":768,\"caption\":\"Pharmaceutical tablet dissolving in amber solution inside a glass beaker during dissolution testing, with lab glassware and digital instrument nearby.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/wiki\\\/why-can-tablet-dissolution-change-during-manufacturing-scale-up\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/chemspx.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Wiki post\",\"item\":\"https:\\\/\\\/chemspx.com\\\/Wiki\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Why can tablet dissolution change during manufacturing scale-up?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/\",\"name\":\"ChemSPX\",\"description\":\"ChemSPX\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/chemspx.com\\\/fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Why can tablet dissolution change during manufacturing scale-up? | ChemSPX","description":"Tablet dissolution changes during manufacturing scale-up due to granulation, compaction, and equipment geometry shifts. Learn what to monitor and fix.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/chemspx.com\/fr\/wiki\/why-can-tablet-dissolution-change-during-manufacturing-scale-up\/","og_locale":"fr_FR","og_type":"article","og_title":"Why can tablet dissolution change during manufacturing scale-up? | ChemSPX","og_description":"Tablet dissolution changes during manufacturing scale-up due to granulation, compaction, and equipment geometry shifts. Learn what to monitor and fix.","og_url":"https:\/\/chemspx.com\/fr\/wiki\/why-can-tablet-dissolution-change-during-manufacturing-scale-up\/","og_site_name":"ChemSPX","og_image":[{"width":1024,"height":768,"url":"https:\/\/chemspx.com\/wp-content\/uploads\/2026\/10\/pharmaceutical-tablet-dissolving-lab-beaker.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"11 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/chemspx.com\/fr\/wiki\/why-can-tablet-dissolution-change-during-manufacturing-scale-up\/","url":"https:\/\/chemspx.com\/fr\/wiki\/why-can-tablet-dissolution-change-during-manufacturing-scale-up\/","name":"Why can tablet dissolution change during manufacturing scale-up? | ChemSPX","isPartOf":{"@id":"https:\/\/chemspx.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/chemspx.com\/fr\/wiki\/why-can-tablet-dissolution-change-during-manufacturing-scale-up\/#primaryimage"},"image":{"@id":"https:\/\/chemspx.com\/fr\/wiki\/why-can-tablet-dissolution-change-during-manufacturing-scale-up\/#primaryimage"},"thumbnailUrl":"https:\/\/chemspx.com\/wp-content\/uploads\/2026\/10\/pharmaceutical-tablet-dissolving-lab-beaker.webp","datePublished":"2026-10-31T06:00:00+00:00","description":"Tablet dissolution changes during manufacturing scale-up due to granulation, compaction, and equipment geometry shifts. Learn what to monitor and fix.","breadcrumb":{"@id":"https:\/\/chemspx.com\/fr\/wiki\/why-can-tablet-dissolution-change-during-manufacturing-scale-up\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/chemspx.com\/fr\/wiki\/why-can-tablet-dissolution-change-during-manufacturing-scale-up\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/chemspx.com\/fr\/wiki\/why-can-tablet-dissolution-change-during-manufacturing-scale-up\/#primaryimage","url":"https:\/\/chemspx.com\/wp-content\/uploads\/2026\/10\/pharmaceutical-tablet-dissolving-lab-beaker.webp","contentUrl":"https:\/\/chemspx.com\/wp-content\/uploads\/2026\/10\/pharmaceutical-tablet-dissolving-lab-beaker.webp","width":1024,"height":768,"caption":"Pharmaceutical tablet dissolving in amber solution inside a glass beaker during dissolution testing, with lab glassware and digital instrument nearby."},{"@type":"BreadcrumbList","@id":"https:\/\/chemspx.com\/fr\/wiki\/why-can-tablet-dissolution-change-during-manufacturing-scale-up\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/chemspx.com\/"},{"@type":"ListItem","position":2,"name":"Wiki post","item":"https:\/\/chemspx.com\/Wiki\/"},{"@type":"ListItem","position":3,"name":"Why can tablet dissolution change during manufacturing scale-up?"}]},{"@type":"WebSite","@id":"https:\/\/chemspx.com\/fr\/#website","url":"https:\/\/chemspx.com\/fr\/","name":"ChemSPX","description":"ChemSPX","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/chemspx.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/wiki_post\/8123","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/wiki_post"}],"about":[{"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/types\/wiki_post"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/media\/8168"}],"wp:attachment":[{"href":"https:\/\/chemspx.com\/fr\/wp-json\/wp\/v2\/media?parent=8123"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}