{"id":2374,"date":"2023-01-03T15:06:11","date_gmt":"2023-01-03T14:06:11","guid":{"rendered":"https:\/\/chemspx.com\/instruments\/findenser-air-condenser\/"},"modified":"2026-07-17T13:10:32","modified_gmt":"2026-07-17T11:10:32","slug":"findenser-air-condenser","status":"publish","type":"instruments","link":"https:\/\/chemspx.com\/nl\/instruments\/findenser-air-condenser\/","title":{"rendered":"Findenser Air Condenser"},"content":{"rendered":"<div class=\"c-centred-text\">\n<h2 data-section-id=\"ths6y1\" data-start=\"28\" data-end=\"104\">Water-free reflux condenser for common laboratory chemistry applications<\/h2>\n<p class=\"PDq2pG_selectionAnchorContainer\" data-start=\"106\" data-end=\"399\">The Findenser Air Condenser is a<strong> water-free alternative to traditional water-cooled reflux condensers.<\/strong> Designed for<strong> solvent volumes from 5 mL to 1 L,<\/strong> it replaces water-cooled condensers in more than 95% of common chemistry applications while eliminating the need for a continuous water supply.<\/p>\n<p data-start=\"401\" data-end=\"699\">By removing running water from the reflux process, Findenser helps reduce water consumption, lowers water purchase and disposal costs, and eliminates the risk of laboratory flooding associated with water-cooled condensers. It also supports laboratory sustainability and water reduction initiatives.<\/p>\n<h3 data-section-id=\"kqf2fi\" data-start=\"701\" data-end=\"724\"><strong>How Findenser works<\/strong><\/h3>\n<p data-start=\"726\" data-end=\"1014\">The patented Findenser design combines an internal glass condenser with an external finned aluminum jacket. A small amount of water is permanently sealed between the glass condenser and the aluminum jacket, creating a sealed assembly that maximizes thermal conductivity and heat transfer.<\/p>\n<p data-start=\"1016\" data-end=\"1282\">The internal glass condenser provides a larger surface area than a conventional air condenser, while the finned aluminum jacket further increases the external cooling surface. Together, these features provide efficient air cooling without the need for running water.<\/p>\n<\/div>\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"49xvxv\" data-start=\"1284\" data-end=\"1303\"><strong>Design features<\/strong><\/h3>\n<p data-start=\"1305\" data-end=\"1409\">The Findenser Air Condenser is designed for straightforward integration into existing laboratory setups.<\/p>\n<p data-start=\"1411\" data-end=\"1439\"><strong>Key design features include:<\/strong><\/p>\n<ul data-start=\"1441\" data-end=\"1918\">\n<li data-section-id=\"o9eb2z\" data-start=\"1441\" data-end=\"1529\">Patented sealed construction with encapsulated thermofluid for efficient heat transfer<\/li>\n<li data-section-id=\"2py0a3\" data-start=\"1530\" data-end=\"1587\">Finned aluminum jacket for high-performance air cooling<\/li>\n<li data-section-id=\"1rgkf8r\" data-start=\"1588\" data-end=\"1627\">Chemically resistant anodized surface<\/li>\n<li data-section-id=\"1erxv9u\" data-start=\"1628\" data-end=\"1696\">Standard ground glass joints compatible with tapered glass sockets<\/li>\n<li data-section-id=\"1ws3oap\" data-start=\"1697\" data-end=\"1745\">Compatible with conventional laboratory clamps<\/li>\n<li data-section-id=\"hr7tfl\" data-start=\"1746\" data-end=\"1798\">Optional clamping kits and PTFE adapters available<\/li>\n<li data-section-id=\"1pmagg2\" data-start=\"1799\" data-end=\"1918\">Contoured anti-roll design that helps prevent rolling and protects the aluminum fins when the condenser is not in use<\/li>\n<\/ul>\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"8t8b4z\" data-start=\"1920\" data-end=\"1940\"><strong>Available models<\/strong><\/h3>\n<p data-start=\"1942\" data-end=\"1955\"><strong data-start=\"1942\" data-end=\"1955\">Findenser<\/strong><\/p>\n<p data-start=\"1957\" data-end=\"2025\">Suitable for vessels up to 2 L with a maximum solvent volume of 1 L.<\/p>\n<ul data-start=\"2027\" data-end=\"2244\">\n<li data-section-id=\"jcaj22\" data-start=\"2027\" data-end=\"2043\">Length: 400 mm<\/li>\n<li data-section-id=\"10joaky\" data-start=\"2044\" data-end=\"2069\">Maximum flask size: 2 L<\/li>\n<li data-section-id=\"srt52u\" data-start=\"2070\" data-end=\"2099\">Maximum solvent volume: 1 L<\/li>\n<li data-section-id=\"1fer9a6\" data-start=\"2100\" data-end=\"2146\">Available with a choice of three joint sizes<\/li>\n<li data-section-id=\"154cvpw\" data-start=\"2147\" data-end=\"2191\">Compatible with standard laboratory clamps<\/li>\n<li data-section-id=\"hr7tfl\" data-start=\"2192\" data-end=\"2244\">Optional clamping kits and PTFE adapters available<\/li>\n<\/ul>\n<p data-start=\"2246\" data-end=\"2264\"><strong data-start=\"2246\" data-end=\"2264\">Findenser Mini<\/strong><\/p>\n<p data-start=\"2266\" data-end=\"2380\">Designed for smaller-scale reflux applications using vessels up to 250 mL with a maximum solvent volume of 125 mL.<\/p>\n<ul data-start=\"2382\" data-end=\"2605\">\n<li data-section-id=\"kkx9su\" data-start=\"2382\" data-end=\"2398\">Length: 275 mm<\/li>\n<li data-section-id=\"aln6e2\" data-start=\"2399\" data-end=\"2427\">Maximum flask size: 250 mL<\/li>\n<li data-section-id=\"1yjb3a4\" data-start=\"2428\" data-end=\"2460\">Maximum solvent volume: 125 mL<\/li>\n<li data-section-id=\"1fer9a6\" data-start=\"2461\" data-end=\"2507\">Available with a choice of three joint sizes<\/li>\n<li data-section-id=\"154cvpw\" data-start=\"2508\" data-end=\"2552\">Compatible with standard laboratory clamps<\/li>\n<li data-section-id=\"hr7tfl\" data-start=\"2553\" data-end=\"2605\">Optional clamping kits and PTFE adapters available<\/li>\n<\/ul>\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"md65md\" data-start=\"2607\" data-end=\"2623\"><strong>Key benefits<\/strong><\/h3>\n<ul data-start=\"2625\" data-end=\"3049\" data-is-last-node=\"\" data-is-only-node=\"\">\n<li data-section-id=\"1icw4mw\" data-start=\"2625\" data-end=\"2709\">Replaces water-cooled condensers in more than 95% of common chemistry applications<\/li>\n<li data-section-id=\"akb62s\" data-start=\"2710\" data-end=\"2757\">Suitable for solvent volumes from 5 mL to 1 L<\/li>\n<li data-section-id=\"twogpg\" data-start=\"2758\" data-end=\"2805\">Eliminates the need for running cooling water<\/li>\n<li data-section-id=\"1e2965h\" data-start=\"2806\" data-end=\"2847\">Reduces the risk of laboratory flooding<\/li>\n<li data-section-id=\"gymx47\" data-start=\"2848\" data-end=\"2910\">Helps lower water consumption and associated operating costs<\/li>\n<li data-section-id=\"11zhpoj\" data-start=\"2911\" data-end=\"2973\">Supports laboratory sustainability and water reduction goals<\/li>\n<li data-section-id=\"1il3dus\" data-start=\"2974\" data-end=\"3049\" data-is-last-node=\"\">Provides efficient air cooling through a patented sealed condenser design<\/li>\n<\/ul>\n<div class=\"c-columns c-columns--thinner \">\n<div class=\"c-benefits__intro\"><\/div>\n<\/div>\n<h3><strong>Technical specifications:\u00a0<\/strong><\/h3>\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td><strong>Findenser<\/strong><\/td>\n<td><strong>Findenser Mini<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Length x Diameter<\/strong><\/td>\n<td>400mm x 72mm<\/td>\n<td>275mm x 72mm<\/td>\n<\/tr>\n<tr>\n<td><strong>Joints<\/strong><\/td>\n<td>B19, B24, B29<\/td>\n<td>B14, B19, B24<\/td>\n<\/tr>\n<tr>\n<td><strong>Weight<\/strong><\/td>\n<td>1200g<\/td>\n<td>670g<\/td>\n<\/tr>\n<tr>\n<td><strong>Inner or wetted parts<\/strong><\/td>\n<td>Borosilicate glass<\/td>\n<td>Borosilicate glass<\/td>\n<\/tr>\n<tr>\n<td><strong>Finned jacket<\/strong><\/td>\n<td>Anodized aluminum<\/td>\n<td>Anodized aluminum<\/td>\n<\/tr>\n<tr>\n<td><strong>Plug and Seal<\/strong><\/td>\n<td>Acetal\u00a0&amp; HT Silicone<\/td>\n<td>Acetal\u00a0&amp; HT Silicone<\/td>\n<\/tr>\n<tr>\n<td><strong>Thermofluid<\/strong><\/td>\n<td>Water<\/td>\n<td>Water<\/td>\n<\/tr>\n<tr>\n<td><strong>Max solvent\u00a0bpt<\/strong><\/td>\n<td>155\u02daC<\/td>\n<td>155\u02daC<\/td>\n<\/tr>\n<tr>\n<td><strong>Oven drying Max Temp.<\/strong><\/td>\n<td>60\u02daC<\/td>\n<td>60\u02daC<\/td>\n<\/tr>\n<tr>\n<td><strong>Dishwasher Max Temp.<\/strong><\/td>\n<td>50\u02daC<\/td>\n<td>50\u02daC<\/td>\n<\/tr>\n<tr>\n<td><strong>Autoclaving<\/strong><\/td>\n<td>Do Not Autoclave<\/td>\n<td>Do Not Autoclave<\/td>\n<\/tr>\n<tr>\n<td><strong>Ambient operating temp.<\/strong><\/td>\n<td>0\u02daC to 24\u02daC<\/td>\n<td>0\u02daC to 24\u02daC<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=\"c-columns__heading\"><\/h3>\n<p>&nbsp;<\/p>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [{\n    \"@type\": \"Question\",\n    \"name\": \"How does a water-free condenser work?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"The Findenser combines an internal glass condenser with an external finned aluminum jacket. A small amount of water is permanently sealed between the glass and aluminum components, creating an efficient heat-transfer system that cools solvent vapors without requiring a continuous water supply.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"What is the advantage of a water-free reflux condenser?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"A water-free reflux condenser eliminates the need for running cooling water during reflux. This helps reduce water consumption, lowers operating costs, and removes the risk of leaks or flooding associated with water-cooled condensers.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Can the Findenser replace a traditional water-cooled condenser?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Yes. The Findenser is designed to replace water-cooled condensers in more than 95% of common laboratory chemistry applications.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Why are laboratories switching to water-free condensers?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Many laboratories are adopting water-free condensers to reduce water usage, improve sustainability, lower utility costs, and simplify reflux setups without compromising cooling performance.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Does the Findenser require a cooling water connection?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"No. The Findenser operates entirely without a running water supply, making it suitable for laboratories looking to reduce water consumption and simplify equipment setup.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"What makes the Findenser more sustainable than a water-cooled condenser?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"By eliminating the need for continuously running cooling water, the Findenser helps reduce water consumption, water purchase costs, wastewater generation, and the environmental impact associated with reflux cooling.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Is the Findenser chemically resistant?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Yes. The anodized aluminum surface is designed to provide chemical resistance for routine laboratory applications.\"\n    }\n  }]\n}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Replaces water-cooled condensers in more than 95% of common chemistry applications<\/p>","protected":false},"featured_media":5721,"template":"","country":[649],"brands":[626],"applications":[587,573,567],"markets":[18,48,22,14,115,38,17,16,34,110,24,117,36,127,35],"class_list":["post-2374","instruments","type-instruments","status-publish","has-post-thumbnail","hentry","country-nl","brands-radleys","applications-batch-synthesis-chemistry","applications-benchtop-and-hotplates","applications-chemistry","markets-agriculture","markets-animal-feed","markets-chemicals-chemicals","markets-chemicals","markets-chemicals-materials","markets-coal-coke-biomass","markets-energy-sustainability","markets-environmental","markets-environmental-services-and-equipment","markets-materials","markets-pharmaceuticals","markets-polymers-rubber","markets-soil-and-surface","markets-waste-management","markets-wastewater-treatment"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Findenser Air Condenser | ChemSPX<\/title>\n<meta name=\"description\" content=\"A water-free alternative to traditional water-cooled reflux condensers replacing water-cooled condensers in +95% of chemistry applications.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/chemspx.com\/nl\/instruments\/findenser-air-condenser\/\" \/>\n<meta property=\"og:locale\" content=\"nl_NL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Findenser Air Condenser | ChemSPX\" \/>\n<meta property=\"og:description\" content=\"A water-free alternative to traditional water-cooled reflux condensers replacing water-cooled condensers in +95% of chemistry applications.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/chemspx.com\/nl\/instruments\/findenser-air-condenser\/\" \/>\n<meta property=\"og:site_name\" content=\"ChemSPX\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-17T11:10:32+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/findenser.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1080\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Geschatte leestijd\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/findenser-air-condenser\\\/\",\"url\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/findenser-air-condenser\\\/\",\"name\":\"Findenser Air Condenser | ChemSPX\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/findenser-air-condenser\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/findenser-air-condenser\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/findenser.webp\",\"datePublished\":\"2023-01-03T14:06:11+00:00\",\"dateModified\":\"2026-07-17T11:10:32+00:00\",\"description\":\"A water-free alternative to traditional water-cooled reflux condensers replacing water-cooled condensers in +95% of chemistry applications.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/findenser-air-condenser\\\/#breadcrumb\"},\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/findenser-air-condenser\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/findenser-air-condenser\\\/#primaryimage\",\"url\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/findenser.webp\",\"contentUrl\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/findenser.webp\",\"width\":1080,\"height\":1080,\"caption\":\"Findenser Air Condenser\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/findenser-air-condenser\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/chemspx.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Instruments\",\"item\":\"https:\\\/\\\/chemspx.com\\\/instruments\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Findenser Air Condenser\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/#website\",\"url\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/\",\"name\":\"ChemSPX\",\"description\":\"ChemSPX\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"nl-NL\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Findenser Air Condenser | ChemSPX","description":"A water-free alternative to traditional water-cooled reflux condensers replacing water-cooled condensers in +95% of chemistry applications.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/chemspx.com\/nl\/instruments\/findenser-air-condenser\/","og_locale":"nl_NL","og_type":"article","og_title":"Findenser Air Condenser | ChemSPX","og_description":"A water-free alternative to traditional water-cooled reflux condensers replacing water-cooled condensers in +95% of chemistry applications.","og_url":"https:\/\/chemspx.com\/nl\/instruments\/findenser-air-condenser\/","og_site_name":"ChemSPX","article_modified_time":"2026-07-17T11:10:32+00:00","og_image":[{"width":1080,"height":1080,"url":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/findenser.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Geschatte leestijd":"3 minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/chemspx.com\/nl\/instruments\/findenser-air-condenser\/","url":"https:\/\/chemspx.com\/nl\/instruments\/findenser-air-condenser\/","name":"Findenser Air Condenser | ChemSPX","isPartOf":{"@id":"https:\/\/chemspx.com\/nl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/chemspx.com\/nl\/instruments\/findenser-air-condenser\/#primaryimage"},"image":{"@id":"https:\/\/chemspx.com\/nl\/instruments\/findenser-air-condenser\/#primaryimage"},"thumbnailUrl":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/findenser.webp","datePublished":"2023-01-03T14:06:11+00:00","dateModified":"2026-07-17T11:10:32+00:00","description":"A water-free alternative to traditional water-cooled reflux condensers replacing water-cooled condensers in +95% of chemistry applications.","breadcrumb":{"@id":"https:\/\/chemspx.com\/nl\/instruments\/findenser-air-condenser\/#breadcrumb"},"inLanguage":"nl-NL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/chemspx.com\/nl\/instruments\/findenser-air-condenser\/"]}]},{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/chemspx.com\/nl\/instruments\/findenser-air-condenser\/#primaryimage","url":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/findenser.webp","contentUrl":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/findenser.webp","width":1080,"height":1080,"caption":"Findenser Air Condenser"},{"@type":"BreadcrumbList","@id":"https:\/\/chemspx.com\/nl\/instruments\/findenser-air-condenser\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/chemspx.com\/"},{"@type":"ListItem","position":2,"name":"Instruments","item":"https:\/\/chemspx.com\/instruments\/"},{"@type":"ListItem","position":3,"name":"Findenser Air Condenser"}]},{"@type":"WebSite","@id":"https:\/\/chemspx.com\/nl\/#website","url":"https:\/\/chemspx.com\/nl\/","name":"ChemSPX","description":"ChemSPX","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/chemspx.com\/nl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"nl-NL"}]}},"_links":{"self":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/instruments\/2374","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/instruments"}],"about":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/types\/instruments"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/media\/5721"}],"wp:attachment":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/media?parent=2374"}],"wp:term":[{"taxonomy":"country","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/country?post=2374"},{"taxonomy":"brands","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/brands?post=2374"},{"taxonomy":"applications","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/applications?post=2374"},{"taxonomy":"markets","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/markets?post=2374"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}