{"id":2375,"date":"2023-01-03T15:06:11","date_gmt":"2023-01-03T14:06:11","guid":{"rendered":"https:\/\/chemspx.com\/instruments\/heat-on\/"},"modified":"2026-07-15T15:05:35","modified_gmt":"2026-07-15T13:05:35","slug":"heat-on-block-system","status":"publish","type":"instruments","link":"https:\/\/chemspx.com\/nl\/instruments\/heat-on\/","title":{"rendered":"Heat-On Block System"},"content":{"rendered":"<h2>Heat-On Block System<\/h2>\n<h3><strong>Safe and efficient heating for round-bottom flasks<\/strong><\/h3>\n<p class=\"isSelectedEnd\">The Heat-O Block System provides a safe, clean and efficient<strong> alternative to oil baths and heating mantles for heating and stirring laboratory vessels<\/strong>. Designed for use on standard laboratory stirring hotplates, the system accommodates vials, tubes and round-bottom flasks from<strong> 10 mL up to 5 L<\/strong>, including Florentine (pear-shaped) flasks.<\/p>\n<p>Heat-On blocks fit all major hotplate brands with a 145 mm diameter top plate. An optional adapter plate is available for hotplates with a 135 mm diameter top plate, while a square hotplate adapter allows use on square top plates up to 200 \u00d7 200 mm.<\/p>\n<h3><strong>Fast and uniform heating<\/strong><\/h3>\n<p class=\"isSelectedEnd\">Heat-On blocks are manufactured from solid aluminum, providing even heat distribution and <strong>rapid heating up to 260 \u00b0C<\/strong>. The lightweight construction contributes to fast heat-up times.<\/p>\n<p class=\"isSelectedEnd\">Heat-up testing has shown that a 250 mL flask of water can reach boiling in less than 11 minutes, faster than both an oil bath and other heating blocks. In another controlled comparison, a 2000 mL Heat-On block containing a 1000 mL flask of wate<strong>r reached boiling 66% faste<\/strong>r than a leading competitor.<\/p>\n<p class=\"isSelectedEnd\">The system also uses<strong> approximately 30% less energy<\/strong> than the leading competitor when boiling water over a seven-hour period.<\/p>\n<h3><strong>Safer than traditional heating methods<\/strong><\/h3>\n<p class=\"isSelectedEnd\">Heat-On eliminates the need for oil baths, reducing the risks associated with hot oil, including spills, oil fires and exposure to fumes. Unlike heating mantles, which can be difficult to clean and may create hot spots, aluminum heating blocks provide a cleaner and more practical solution for laboratory heating.<\/p>\n<p class=\"isSelectedEnd\">The unique well design helps prevent flask cracking during cooling, while optional PTFE Safety Covers reduce the risk of accidental contact with hot block surfaces. The covers lower the surface temperature by up to 50% and can reduce energy consumption by approximately 15%. Temperature probes and lifting handles remain fully accessible when the covers are installed.<\/p>\n<h3><strong>Block finishes<\/strong><\/h3>\n<p class=\"isSelectedEnd\">Heat-On blocks are available with two surface finishes.<\/p>\n<p><strong>Fluoropolymer coating<\/strong><\/p>\n<p class=\"isSelectedEnd\">The fluoropolymer-coated blocks offer:<\/p>\n<ul data-spread=\"false\">\n<li>Excellent chemical resistance to most solvents, acids and alkalis<\/li>\n<li>Easy cleaning<\/li>\n<li>Extended product life<\/li>\n<li>Reduced heat-up time<\/li>\n<\/ul>\n<p><strong>Anodised finish<\/strong><\/p>\n<p class=\"isSelectedEnd\">The anodized version provides:<\/p>\n<ul data-spread=\"false\">\n<li>Good resistance to common laboratory solvents<\/li>\n<li>A durable hard-anodized surface<\/li>\n<li>Good impact resistance<\/li>\n<li>Easy cleaning<\/li>\n<li>A lower-cost alternative<\/li>\n<\/ul>\n<h3><strong>Flexible block configurations<\/strong><\/h3>\n<p class=\"isSelectedEnd\">More than 50 block styles and sizes are available for laboratory vessels from 10 mL to 5 L.<\/p>\n<p class=\"isSelectedEnd\"><strong>The range includes:<\/strong><\/p>\n<ul data-spread=\"false\">\n<li>Round-bottom flask blocks<\/li>\n<li>Florentine (pear-shaped) flask blocks<\/li>\n<li>Tube and vial blocks<\/li>\n<li>Multi-well blocks<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">The Multi-well holder accepts one or two interchangeable inserts.<\/p>\n<p class=\"isSelectedEnd\"><strong>Available inserts include:<\/strong><\/p>\n<ul data-spread=\"false\">\n<li>Flask inserts for 10, 25, 50, 100 and 150 mL flasks<\/li>\n<li>Multi-tube inserts for 16 mm, 17 mm, 20 mm, 24 mm, 28 mm and 1-inch tubes or vials<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">Flask inserts also feature cut-away sides for use with two-neck and three-neck flasks.<\/p>\n<p>Both the holder and inserts are available with either a fluoropolymer coating or an anodized finish.<\/p>\n<h3><strong>Practical design features<\/strong><\/h3>\n<p class=\"isSelectedEnd\">Heat-On incorporates several features that improve day-to-day laboratory use, including:<\/p>\n<ul data-spread=\"false\">\n<li>Unique well design that helps prevent flask cracking<\/li>\n<li>Two probe holes for 3 mm temperature probes<\/li>\n<li>Optional detachable lifting handles<\/li>\n<li>Compatibility with most leading laboratory hotplates<\/li>\n<\/ul>\n<h3><strong>Heat-On Heat-up Summary<\/strong><\/h3>\n<p>The following data summarizes the time Heat-On takes to boil various volumes of water. It was measured using a Carousel Stirring Hotplate set at its maximum operating temperature.<\/p>\n<table>\n<tbody>\n<tr>\n<td><strong>Flask<\/strong><br \/>\n<strong>Volume (ml)<\/strong><\/td>\n<td><strong>Water<\/strong><br \/>\n<strong>Volume (ml)<\/strong><\/td>\n<td><strong>Hotplate<\/strong><br \/>\n<strong>Temperature <\/strong><strong>\uff9f<\/strong><strong>C<\/strong><\/td>\n<td><strong>Contents time\u00a0to reach boiling<\/strong><\/td>\n<\/tr>\n<tr>\n<td>10<\/td>\n<td>6<\/td>\n<td>310<\/td>\n<td>4 min 48 sec<\/td>\n<\/tr>\n<tr>\n<td>25<\/td>\n<td>15<\/td>\n<td>310<\/td>\n<td>5 min 54 sec<\/td>\n<\/tr>\n<tr>\n<td>50<\/td>\n<td>30<\/td>\n<td>310<\/td>\n<td>7 min 12 sec<\/td>\n<\/tr>\n<tr>\n<td>100<\/td>\n<td>60<\/td>\n<td>310<\/td>\n<td>7 min 54 sec<\/td>\n<\/tr>\n<tr>\n<td>150<\/td>\n<td>100<\/td>\n<td>310<\/td>\n<td>10 min 36 sec<\/td>\n<\/tr>\n<tr>\n<td>250<\/td>\n<td>150<\/td>\n<td>310<\/td>\n<td>9 min 48 sec<\/td>\n<\/tr>\n<tr>\n<td>500<\/td>\n<td>300<\/td>\n<td>310<\/td>\n<td>13 min 30 sec<\/td>\n<\/tr>\n<tr>\n<td>1000<\/td>\n<td>600<\/td>\n<td>310<\/td>\n<td>17 min 06 sec<\/td>\n<\/tr>\n<tr>\n<td>2000<\/td>\n<td>1200<\/td>\n<td>310<\/td>\n<td>26 min 18 sec<\/td>\n<\/tr>\n<tr>\n<td>3000<\/td>\n<td>2000<\/td>\n<td>310<\/td>\n<td>39 min 36 sec<\/td>\n<\/tr>\n<tr>\n<td>5000<\/td>\n<td>3000<\/td>\n<td>310<\/td>\n<td>51 min 00 sec<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [{\n    \"@type\": \"Question\",\n    \"name\": \"What is the Heat-On Block System?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"The Heat-On Block System is a laboratory heating solution designed as an alternative to oil baths and heating mantles. It enables safe heating and stirring of round-bottom flasks, tubes, and vials on standard laboratory stirring hotplates.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"How does the Heat-On Block System differ from oil baths?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"The Heat-On Block System eliminates the need for hot oil, reducing the risks associated with oil spills, oil fires, and oil fumes. It also provides a cleaner heating method while simplifying maintenance and laboratory housekeeping.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Can the Heat-On Block System be used with Florentine flasks?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Yes. Dedicated Heat-On blocks are available for Florentine, or pear-shaped, flasks, allowing efficient heating and stirring of these vessel types.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"How does aluminum improve heating performance?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Solid aluminum distributes heat evenly across the block surface, supporting uniform temperature control and reducing localized hot spots during heating.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"How fast does the Heat-On Block System heat samples?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Heat-up testing showed that a 250 mL flask of water reached boiling in less than 11 minutes. In a separate comparison, a 2000 mL Heat-On block brought a 1000 mL flask of water to boiling 66% faster than a leading competitor.\"\n    }\n  }]\n}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Alternative for oil baths and heating mantles for heating and stirring laboratory vessels<\/p>","protected":false},"featured_media":5725,"template":"","country":[649],"brands":[626],"applications":[573,567],"markets":[18,48,14,115,22,38,17,16,34,47,110,24,117,36,127,35],"class_list":["post-2375","instruments","type-instruments","status-publish","has-post-thumbnail","hentry","country-nl","brands-radleys","applications-benchtop-and-hotplates","applications-chemistry","markets-agriculture","markets-animal-feed","markets-chemicals","markets-chemicals-materials","markets-chemicals-chemicals","markets-coal-coke-biomass","markets-energy-sustainability","markets-environmental","markets-environmental-services-and-equipment","markets-fertilizers-and-chemicals","markets-materials","markets-pharmaceuticals","markets-polymers-rubber","markets-soil-and-surface","markets-waste-management","markets-wastewater-treatment"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Heat-On Block System | ChemSPX<\/title>\n<meta name=\"description\" content=\"A safe, clean and efficient alternative to oil baths and heating mantles for heating and stirring laboratory vessels.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/chemspx.com\/nl\/instruments\/heat-on\/\" \/>\n<meta property=\"og:locale\" content=\"nl_NL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Heat-On Block System | ChemSPX\" \/>\n<meta property=\"og:description\" content=\"A safe, clean and efficient alternative to oil baths and heating mantles for heating and stirring laboratory vessels.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/chemspx.com\/nl\/instruments\/heat-on\/\" \/>\n<meta property=\"og:site_name\" content=\"ChemSPX\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-15T13:05:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/heat-on-.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1080\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Geschatte leestijd\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/heat-on\\\/\",\"url\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/heat-on\\\/\",\"name\":\"Heat-On Block System | ChemSPX\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/heat-on\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/heat-on\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/heat-on-.webp\",\"datePublished\":\"2023-01-03T14:06:11+00:00\",\"dateModified\":\"2026-07-15T13:05:35+00:00\",\"description\":\"A safe, clean and efficient alternative to oil baths and heating mantles for heating and stirring laboratory vessels.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/heat-on\\\/#breadcrumb\"},\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/heat-on\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/heat-on\\\/#primaryimage\",\"url\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/heat-on-.webp\",\"contentUrl\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/heat-on-.webp\",\"width\":1080,\"height\":1080,\"caption\":\"Heat-On Block System\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/heat-on\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/chemspx.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Instruments\",\"item\":\"https:\\\/\\\/chemspx.com\\\/instruments\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Heat-On Block System\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/#website\",\"url\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/\",\"name\":\"ChemSPX\",\"description\":\"ChemSPX\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"nl-NL\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Heat-On Block System | ChemSPX","description":"A safe, clean and efficient alternative to oil baths and heating mantles for heating and stirring laboratory vessels.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/chemspx.com\/nl\/instruments\/heat-on\/","og_locale":"nl_NL","og_type":"article","og_title":"Heat-On Block System | ChemSPX","og_description":"A safe, clean and efficient alternative to oil baths and heating mantles for heating and stirring laboratory vessels.","og_url":"https:\/\/chemspx.com\/nl\/instruments\/heat-on\/","og_site_name":"ChemSPX","article_modified_time":"2026-07-15T13:05:35+00:00","og_image":[{"width":1080,"height":1080,"url":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/heat-on-.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Geschatte leestijd":"4 minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/chemspx.com\/nl\/instruments\/heat-on\/","url":"https:\/\/chemspx.com\/nl\/instruments\/heat-on\/","name":"Heat-On Block System | ChemSPX","isPartOf":{"@id":"https:\/\/chemspx.com\/nl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/chemspx.com\/nl\/instruments\/heat-on\/#primaryimage"},"image":{"@id":"https:\/\/chemspx.com\/nl\/instruments\/heat-on\/#primaryimage"},"thumbnailUrl":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/heat-on-.webp","datePublished":"2023-01-03T14:06:11+00:00","dateModified":"2026-07-15T13:05:35+00:00","description":"A safe, clean and efficient alternative to oil baths and heating mantles for heating and stirring laboratory vessels.","breadcrumb":{"@id":"https:\/\/chemspx.com\/nl\/instruments\/heat-on\/#breadcrumb"},"inLanguage":"nl-NL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/chemspx.com\/nl\/instruments\/heat-on\/"]}]},{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/chemspx.com\/nl\/instruments\/heat-on\/#primaryimage","url":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/heat-on-.webp","contentUrl":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/heat-on-.webp","width":1080,"height":1080,"caption":"Heat-On Block System"},{"@type":"BreadcrumbList","@id":"https:\/\/chemspx.com\/nl\/instruments\/heat-on\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/chemspx.com\/"},{"@type":"ListItem","position":2,"name":"Instruments","item":"https:\/\/chemspx.com\/instruments\/"},{"@type":"ListItem","position":3,"name":"Heat-On Block System"}]},{"@type":"WebSite","@id":"https:\/\/chemspx.com\/nl\/#website","url":"https:\/\/chemspx.com\/nl\/","name":"ChemSPX","description":"ChemSPX","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/chemspx.com\/nl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"nl-NL"}]}},"_links":{"self":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/instruments\/2375","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/instruments"}],"about":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/types\/instruments"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/media\/5725"}],"wp:attachment":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/media?parent=2375"}],"wp:term":[{"taxonomy":"country","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/country?post=2375"},{"taxonomy":"brands","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/brands?post=2375"},{"taxonomy":"applications","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/applications?post=2375"},{"taxonomy":"markets","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/markets?post=2375"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}