{"id":2381,"date":"2023-01-03T15:06:16","date_gmt":"2023-01-03T14:06:16","guid":{"rendered":"https:\/\/chemspx.com\/instruments\/breeze-storm\/"},"modified":"2026-07-16T13:25:35","modified_gmt":"2026-07-16T11:25:35","slug":"breeze-storm-heating-cooling-work-station","status":"publish","type":"instruments","link":"https:\/\/chemspx.com\/nl\/instruments\/breeze-storm\/","title":{"rendered":"Breeze &#038; Storm"},"content":{"rendered":"<h2>Breeze Heating\/Cooling Work Station<\/h2>\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"utxchj\" data-start=\"40\" data-end=\"123\"><strong>Compact heating and cooling workstation for precise solution temperature control<\/strong><\/h3>\n<p data-start=\"125\" data-end=\"509\">The Breeze\u2122 Heating\/Cooling Work Station is an add-on module for the <a href=\"https:\/\/chemspx.com\/instruments\/carrousel-6-plus\/\" target=\"_blank\" rel=\"noopener\">Carousel 6 Plus Reaction Station<\/a> and the <a href=\"https:\/\/chemspx.com\/instruments\/tornado\/\" target=\"_blank\" rel=\"noopener\">Tornado overhead stirring system<\/a>. When connected to a circulator, it creates a parallel process reactor capable of rapid heating and cooling, making it <strong>suitable for applications that require accurate solution temperature control, such as crystallization studies.<\/strong><\/p>\n<p data-start=\"511\" data-end=\"737\">Its compact internal volume allows the system<strong> to respond quickly to changes in thermofluid temperature,<\/strong> while the internal design promotes efficient heat transfer and minimizes temperature variation across the working surface.<\/p>\n<h3 data-section-id=\"33vy4b\" data-start=\"739\" data-end=\"770\"><strong>Flexible temperature control<\/strong><\/h3>\n<p data-start=\"772\" data-end=\"919\">The Breeze Heating\/Cooling Work Station enables rapid heating or cooling of individual or multiple reaction vessels with capacities up to 5 liters.<\/p>\n<p data-start=\"921\" data-end=\"939\"><strong>The system offers:<\/strong><\/p>\n<ul data-start=\"941\" data-end=\"1269\">\n<li data-section-id=\"pngul\" data-start=\"941\" data-end=\"994\">Thermofluid operating range from -85 \u00b0C to +235 \u00b0C<\/li>\n<li data-section-id=\"mmlp77\" data-start=\"995\" data-end=\"1061\">Solution temperature range from approximately -30 \u00b0C to +165 \u00b0C<\/li>\n<li data-section-id=\"een84\" data-start=\"1062\" data-end=\"1172\">A 135 mm diameter top plate compatible with the <a href=\"https:\/\/chemspx.com\/instruments\/carrousel-6-plus\/\" target=\"_blank\" rel=\"noopener\">Carousel 6 Plus<\/a>, <a href=\"https:\/\/chemspx.com\/instruments\/tornado\/\" target=\"_blank\" rel=\"noopener\">Tornado<\/a>, <a href=\"https:\/\/chemspx.com\/instruments\/heat-on\/\" target=\"_blank\" rel=\"noopener\">Heat-On<\/a>\u00a0and other reaction blocks<\/li>\n<li data-section-id=\"1ji0wtd\" data-start=\"1173\" data-end=\"1269\">Mechanical stirring using the Tornado overhead stirrer or another compatible overhead stirrer<\/li>\n<\/ul>\n<h3 data-section-id=\"k0e5t9\" data-start=\"1271\" data-end=\"1318\"><strong>Easy integration with laboratory circulators<\/strong><\/h3>\n<p data-start=\"1320\" data-end=\"1458\">Breeze is equipped with M16 hose connections, making it compatible with all major circulator brands. Adapters are available when required. The anodized aluminum block heats and cools rapidly and can be easily detached from the base for convenient handling.<\/p>\n<h3 data-section-id=\"1w9xu6a\" data-start=\"1580\" data-end=\"1610\"><strong>Stable and practical design<\/strong><\/h3>\n<p data-start=\"1612\" data-end=\"1896\">The workstation is supplied with a removable aluminum stand featuring integrated stainless steel support rods to provide a stable and secure setup. The stand also functions as a drip tray, collecting spills or condensation that may occur during operation at sub-ambient temperatures. The aluminum block can be easily unscrewed from the drip tray when needed.<\/p>\n<h3 data-section-id=\"t4ytit\" data-start=\"1975\" data-end=\"1990\"><strong>Key features<\/strong><\/h3>\n<ul data-start=\"1992\" data-end=\"2858\">\n<li data-section-id=\"yt6o1v\" data-start=\"1992\" data-end=\"2072\">Add-on heating and cooling module for the <a href=\"https:\/\/chemspx.com\/instruments\/carrousel-6-plus\/\" target=\"_blank\" rel=\"noopener\">Carousel 6 Plus<\/a> and <a href=\"https:\/\/chemspx.com\/instruments\/tornado\/\" target=\"_blank\" rel=\"noopener\">Tornado<\/a> systems<\/li>\n<li data-section-id=\"1rll55d\" data-start=\"2073\" data-end=\"2137\">Rapid heating and cooling for reaction vessels up to 5 liters<\/li>\n<li data-section-id=\"1rll55d\" data-start=\"2073\" data-end=\"2137\">Suitable for applications requiring precise solution temperature control, including crystallization studies<\/li>\n<li data-section-id=\"1nsnfek\" data-start=\"2249\" data-end=\"2304\">Thermofluid temperature range from -85 \u00b0C to +235 \u00b0C<\/li>\n<li data-section-id=\"mmlp77\" data-start=\"2305\" data-end=\"2371\">Solution temperature range from approximately -30 \u00b0C to +165 \u00b0C<\/li>\n<li data-section-id=\"16pbgd9\" data-start=\"2372\" data-end=\"2424\">Compact internal volume for fast thermal response<\/li>\n<li data-section-id=\"udtiio\" data-start=\"2425\" data-end=\"2513\">Optimized internal design for efficient heat transfer and uniform surface temperature<\/li>\n<li data-section-id=\"1cf6fu4\" data-start=\"2514\" data-end=\"2618\">135 mm diameter top plate compatible with Carousel 6 Plus, Tornado,<a href=\"https:\/\/chemspx.com\/instruments\/heat-on\/\" target=\"_blank\" rel=\"noopener\"> Heat-On<\/a> and other reaction blocks<\/li>\n<li data-section-id=\"1k290tf\" data-start=\"2619\" data-end=\"2686\">M16 hose connections compatible with most laboratory circulators<\/li>\n<li data-section-id=\"gjd53d\" data-start=\"2687\" data-end=\"2774\">Removable aluminum stand with integrated drip tray and stainless steel support rods<\/li>\n<li data-section-id=\"1rvvtcq\" data-start=\"2775\" data-end=\"2858\">Anodized aluminum block that can be detached easily for cleaning or maintenance<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h2 data-section-id=\"1rstjkg\" data-start=\"0\" data-end=\"37\">Storm Heating\/Cooling Work Station<\/h2>\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"ge9e4t\" data-start=\"39\" data-end=\"111\"><strong>Heating and cooling workstation for controlled steady-state reactions<\/strong><\/h3>\n<p data-start=\"113\" data-end=\"478\">The Storm\u2122 Heating\/Cooling Work Station is an add-on module designed for use with the <a href=\"https:\/\/chemspx.com\/instruments\/carrousel-6-plus\/\" target=\"_blank\" rel=\"noopener\">Carousel 6 Plus Reaction Station<\/a> and <a href=\"https:\/\/chemspx.com\/instruments\/tornado\/\" target=\"_blank\" rel=\"noopener\">Tornado overhead stirring system<\/a>. When combined with a suitable circulator and overhead stirrer, it creates a parallel process reactor that provides controlled heating, cooling and mechanical stirring for process optimization and development.<\/p>\n<p data-start=\"480\" data-end=\"698\">The system is capable of mechanically stirring up to <strong>six reaction flasks ranging from 5 to 250 mL.<\/strong> Because Storm does not include an integrated stirring mechanism, stirring is provided by a compatible overhead stirrer.<\/p>\n<h3 data-section-id=\"18fq96d\" data-start=\"700\" data-end=\"730\"><strong>Precise temperature control<\/strong><\/h3>\n<p data-start=\"732\" data-end=\"1010\">Storm is designed for temperature-controlled, steady-state reactions. Its unique internal construction maximizes heat transfer from the circulating thermofluid by directing thermal energy towards the contoured top plate while minimizing temperature variation across the surface. The workstation accepts thermofluid temperatures from -85 \u00b0C to +235 \u00b0C, providing typical solution temperatures within the reaction flasks from approximately -65 \u00b0C to +200 \u00b0C.<\/p>\n<p data-start=\"1191\" data-end=\"1209\"><strong>The system offers:<\/strong><\/p>\n<ul data-start=\"1211\" data-end=\"1499\">\n<li data-section-id=\"1f9pjec\" data-start=\"1211\" data-end=\"1263\">Heating and cooling for up to six reaction flasks<\/li>\n<li data-section-id=\"12j9klv\" data-start=\"1264\" data-end=\"1308\">Typical flask capacities from 5 to 250 mL<\/li>\n<li data-section-id=\"1swqved\" data-start=\"1309\" data-end=\"1403\">A contoured top plate designed specifically for the Carousel 6 Plus and Tornado combination<\/li>\n<li data-section-id=\"p5ax6j\" data-start=\"1404\" data-end=\"1499\">A 135 mm diameter top plate that is also compatible with Heat-On and similar reaction blocks<\/li>\n<\/ul>\n<h3 data-section-id=\"14ugthv\" data-start=\"1501\" data-end=\"1532\"><strong>Efficient and safe operation<\/strong><\/h3>\n<p data-start=\"1534\" data-end=\"1783\">The insulated outer case reduces heat loss while helping protect users from contact with hot or cold thermofluid. A fluoropolymer splash guard provides chemical resistance and reduces heat transfer between the heated block and the insulated housing.<\/p>\n<p data-start=\"1785\" data-end=\"2007\">An optional removable two-piece PTFE insulating plate further improves heating and cooling efficiency when used with the Carousel 6 Plus. It also helps reduce ice formation on exposed surfaces during sub-ambient operation.<\/p>\n<h3 data-section-id=\"t4ytit\" data-start=\"2449\" data-end=\"2464\"><strong>Key features<\/strong><\/h3>\n<ul data-start=\"2466\" data-end=\"3283\" data-is-last-node=\"\" data-is-only-node=\"\">\n<li data-section-id=\"1gnlpuq\" data-start=\"2466\" data-end=\"2551\">Add-on heating and cooling workstation for the Carousel 6 Plus and Tornado systems<\/li>\n<li data-section-id=\"aqirw8\" data-start=\"2552\" data-end=\"2601\">Suitable for controlled steady-state reactions<\/li>\n<li data-section-id=\"1f9pjec\" data-start=\"2602\" data-end=\"2654\">Heating and cooling for up to six reaction flasks<\/li>\n<li data-section-id=\"1d6m2bk\" data-start=\"2655\" data-end=\"2699\">Typical reaction volumes from 5 to 250 mL<\/li>\n<li data-section-id=\"pngul\" data-start=\"2700\" data-end=\"2753\">Thermofluid operating range from -85 \u00b0C to +235 \u00b0C<\/li>\n<li data-section-id=\"rf4jt\" data-start=\"2754\" data-end=\"2828\">Typical solution temperature range from approximately -65 \u00b0C to +200 \u00b0C<\/li>\n<li data-section-id=\"13jfw8f\" data-start=\"2829\" data-end=\"2922\">Internal design optimized for efficient heat transfer and uniform temperature distribution<\/li>\n<li data-section-id=\"1h63e6z\" data-start=\"2923\" data-end=\"2999\">Insulated outer housing to minimize heat loss and improve operator safety<\/li>\n<li data-section-id=\"crv03v\" data-start=\"3000\" data-end=\"3050\">Chemically resistant fluoropolymer splash guard<\/li>\n<li data-section-id=\"188va5l\" data-start=\"3051\" data-end=\"3142\">Optional PTFE insulating plate for improved thermal efficiency and reduced ice formation<\/li>\n<li data-section-id=\"zbmkf2\" data-start=\"3143\" data-end=\"3202\">M24 hose fittings compatible with laboratory circulators<\/li>\n<li data-section-id=\"us66ce\" data-start=\"3203\" data-end=\"3283\" data-is-last-node=\"\">Compatible with Carousel 6 Plus, Tornado, Heat-On and similar reaction blocks<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<div class=\"c-centred-text\">\n<h2>What is the difference between Breeze and Storm?<\/h2>\n<\/div>\n<div class=\"c-columns c-columns--thinner \">\n<div class=\"c-columns__col white c-columns__col--left\">\n<div class=\"c-columns__content\">\n<table>\n<thead>\n<tr>\n<th><\/th>\n<th><strong>Breeze<\/strong><\/th>\n<th><strong>Storm<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Design<\/strong><\/td>\n<td>Compact bench\u2011top design without insulation<\/td>\n<td>Insulated design with advanced internal fluid path<\/td>\n<\/tr>\n<tr>\n<td><strong>Temperature range<\/strong><\/td>\n<td>-30\u202f\u00b0C to +165\u202f\u00b0C<\/td>\n<td>-65\u202f\u00b0C to +200\u202f\u00b0C<\/td>\n<\/tr>\n<tr>\n<td><strong>Response time<\/strong><\/td>\n<td>Very fast temperature changes<\/td>\n<td>Optimized for stable long\u2011term operation<\/td>\n<\/tr>\n<tr>\n<td><strong>Temperature stability<\/strong><\/td>\n<td>Designed for applications requiring frequent temperature adjustments<\/td>\n<td>Provides highly stable temperatures with minimal surface variation<\/td>\n<\/tr>\n<tr>\n<td><strong>Heat transfer performance<\/strong><\/td>\n<td>Good heat transfer in a compact format<\/td>\n<td>Enhanced heat transfer through insulated construction<\/td>\n<\/tr>\n<tr>\n<td><strong>Footprint<\/strong><\/td>\n<td>Small<\/td>\n<td>Larger than Breeze<\/td>\n<\/tr>\n<tr>\n<td><strong>Best suited for<\/strong><\/td>\n<td>Solution temperature control and crystallization studies<\/td>\n<td>Steady\u2011state reactions requiring prolonged temperature control<\/td>\n<\/tr>\n<tr>\n<td><strong>Key advantage<\/strong><\/td>\n<td>Fast response to temperature changes<\/td>\n<td>Wide operating range and excellent temperature uniformity<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3><strong>Breeze vs. Storm: technical specifications\u00a0<\/strong><\/h3>\n<table>\n<thead>\n<tr>\n<th><\/th>\n<th><strong>Breeze<\/strong><\/th>\n<th><strong>Storm<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Solution temperature range<\/strong><\/td>\n<td>-30\u202f\u00b0C to +165\u202f\u00b0C<\/td>\n<td>-65\u202f\u00b0C to +200\u202f\u00b0C<\/td>\n<\/tr>\n<tr>\n<td><strong>Thermofluid operating limits<\/strong><\/td>\n<td>-85\u202f\u00b0C to +235\u202f\u00b0C<\/td>\n<td>-85\u202f\u00b0C to +235\u202f\u00b0C<\/td>\n<\/tr>\n<tr>\n<td><strong>Control by solution temperature<\/strong><\/td>\n<td>Yes<\/td>\n<td>No<\/td>\n<\/tr>\n<tr>\n<td><strong>Typical applications<\/strong><\/td>\n<td>Variable temperature applications such as crystallization<\/td>\n<td>Steady-state temperature reactions such as parallel chemistry<\/td>\n<\/tr>\n<tr>\n<td><strong>Hose fittings<\/strong><\/td>\n<td>M16 (16\u202fmm)<\/td>\n<td>M24 (24\u202fmm)<\/td>\n<\/tr>\n<tr>\n<td><strong>Dimensions<\/strong><\/td>\n<td>135 \u00d7 80\u202fmm<\/td>\n<td>367 \u00d7 143.5\u202fmm<\/td>\n<\/tr>\n<tr>\n<td><strong>Insulated<\/strong><\/td>\n<td>No<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td><strong>Weight<\/strong><\/td>\n<td>1.6\u202fkg (without stand)<br \/>\n3.2\u202fkg (with stand)<\/td>\n<td>13\u202fkg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>Recommended applications\u00a0<\/strong><\/h3>\n<table>\n<thead>\n<tr>\n<th><strong>Application<\/strong><\/th>\n<th><strong>Recommended module<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Crystallization studies<\/td>\n<td>Breeze<\/td>\n<\/tr>\n<tr>\n<td>Rapid temperature cycling<\/td>\n<td>Breeze<\/td>\n<\/tr>\n<tr>\n<td>Long\u2011duration reactions<\/td>\n<td>Storm<\/td>\n<\/tr>\n<tr>\n<td>Low\u2011temperature reactions down to -65\u202f\u00b0C<\/td>\n<td>Storm<\/td>\n<\/tr>\n<tr>\n<td>High\u2011temperature reactions up to 200\u202f\u00b0C<\/td>\n<td>Storm<\/td>\n<\/tr>\n<tr>\n<td>Processes requiring highly stable temperatures<\/td>\n<td>Storm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [{\n    \"@type\": \"Question\",\n    \"name\": \"Why is the Breeze suitable for crystallization studies?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"The Breeze is designed for precise solution temperature control and responds quickly to temperature changes due to its compact internal volume. This makes it suitable for crystallization studies and other applications that require frequent temperature adjustments.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"What are the key benefits of the Breeze Heating\/Cooling Work Station?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"The Breeze provides rapid heating and cooling, solution temperature control from approximately -30 \u00b0C to +165 \u00b0C, compatibility with major circulators, support for reaction vessels up to 5 liters, and fast thermal response for crystallization and variable-temperature reactions.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"What makes the Storm suitable for steady-state reactions?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"The Storm uses an insulated design and an internal construction optimized for efficient heat transfer and uniform temperature distribution. This allows highly stable temperature control during long-duration reactions.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"What is the purpose of the fluoropolymer splash guard?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"The fluoropolymer splash guard provides chemical resistance and reduces heat transfer between the heated block and the insulated housing.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"What is the difference between Breeze and Storm?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"The Breeze is optimized for applications that require rapid temperature changes and precise solution temperature control, while the Storm is designed for highly stable, steady-state reactions that require long-term temperature consistency.\"\n    }\n  }]\n}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Compact heating and cooling workstation for precise solution temperature control<\/p>","protected":false},"featured_media":5238,"template":"","country":[649],"brands":[626],"applications":[587,567,651],"markets":[18,48,14,22,115,47,110,24,117,23],"class_list":["post-2381","instruments","type-instruments","status-publish","has-post-thumbnail","hentry","country-nl","brands-radleys","applications-batch-synthesis-chemistry","applications-chemistry","applications-parallel-reaction","markets-agriculture","markets-animal-feed","markets-chemicals","markets-chemicals-chemicals","markets-chemicals-materials","markets-fertilizers-and-chemicals","markets-materials","markets-pharmaceuticals","markets-polymers-rubber","markets-specialty-chemicals"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Breeze &amp; Storm | Heating\/Cooling Work Station | ChemSPX<\/title>\n<meta name=\"description\" content=\"Heating and cooling workstation for controlled steady-state reactions &amp; precise solution temperature control.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/chemspx.com\/nl\/instruments\/breeze-storm\/\" \/>\n<meta property=\"og:locale\" content=\"nl_NL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Breeze &amp; Storm | Heating\/Cooling Work Station | ChemSPX\" \/>\n<meta property=\"og:description\" content=\"Heating and cooling workstation for controlled steady-state reactions &amp; precise solution temperature control.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/chemspx.com\/nl\/instruments\/breeze-storm\/\" \/>\n<meta property=\"og:site_name\" content=\"ChemSPX\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-16T11:25:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/breeze-and-storm-.png\" \/>\n\t<meta property=\"og:image:width\" content=\"412\" \/>\n\t<meta property=\"og:image:height\" content=\"547\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Geschatte leestijd\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/breeze-storm\\\/\",\"url\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/breeze-storm\\\/\",\"name\":\"Breeze & Storm | Heating\\\/Cooling Work Station | ChemSPX\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/breeze-storm\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/breeze-storm\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/breeze-and-storm-.png\",\"datePublished\":\"2023-01-03T14:06:16+00:00\",\"dateModified\":\"2026-07-16T11:25:35+00:00\",\"description\":\"Heating and cooling workstation for controlled steady-state reactions & precise solution temperature control.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/breeze-storm\\\/#breadcrumb\"},\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/breeze-storm\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/breeze-storm\\\/#primaryimage\",\"url\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/breeze-and-storm-.png\",\"contentUrl\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/breeze-and-storm-.png\",\"width\":412,\"height\":547,\"caption\":\"Heating\\\/cooling work station\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/breeze-storm\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/chemspx.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Instruments\",\"item\":\"https:\\\/\\\/chemspx.com\\\/instruments\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Breeze &#038; Storm\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/#website\",\"url\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/\",\"name\":\"ChemSPX\",\"description\":\"ChemSPX\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"nl-NL\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Breeze & Storm | Heating\/Cooling Work Station | ChemSPX","description":"Heating and cooling workstation for controlled steady-state reactions & precise solution temperature control.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/chemspx.com\/nl\/instruments\/breeze-storm\/","og_locale":"nl_NL","og_type":"article","og_title":"Breeze & Storm | Heating\/Cooling Work Station | ChemSPX","og_description":"Heating and cooling workstation for controlled steady-state reactions & precise solution temperature control.","og_url":"https:\/\/chemspx.com\/nl\/instruments\/breeze-storm\/","og_site_name":"ChemSPX","article_modified_time":"2026-07-16T11:25:35+00:00","og_image":[{"width":412,"height":547,"url":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/breeze-and-storm-.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Geschatte leestijd":"5 minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/chemspx.com\/nl\/instruments\/breeze-storm\/","url":"https:\/\/chemspx.com\/nl\/instruments\/breeze-storm\/","name":"Breeze & Storm | Heating\/Cooling Work Station | ChemSPX","isPartOf":{"@id":"https:\/\/chemspx.com\/nl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/chemspx.com\/nl\/instruments\/breeze-storm\/#primaryimage"},"image":{"@id":"https:\/\/chemspx.com\/nl\/instruments\/breeze-storm\/#primaryimage"},"thumbnailUrl":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/breeze-and-storm-.png","datePublished":"2023-01-03T14:06:16+00:00","dateModified":"2026-07-16T11:25:35+00:00","description":"Heating and cooling workstation for controlled steady-state reactions & precise solution temperature control.","breadcrumb":{"@id":"https:\/\/chemspx.com\/nl\/instruments\/breeze-storm\/#breadcrumb"},"inLanguage":"nl-NL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/chemspx.com\/nl\/instruments\/breeze-storm\/"]}]},{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/chemspx.com\/nl\/instruments\/breeze-storm\/#primaryimage","url":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/breeze-and-storm-.png","contentUrl":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/breeze-and-storm-.png","width":412,"height":547,"caption":"Heating\/cooling work station"},{"@type":"BreadcrumbList","@id":"https:\/\/chemspx.com\/nl\/instruments\/breeze-storm\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/chemspx.com\/"},{"@type":"ListItem","position":2,"name":"Instruments","item":"https:\/\/chemspx.com\/instruments\/"},{"@type":"ListItem","position":3,"name":"Breeze &#038; Storm"}]},{"@type":"WebSite","@id":"https:\/\/chemspx.com\/nl\/#website","url":"https:\/\/chemspx.com\/nl\/","name":"ChemSPX","description":"ChemSPX","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/chemspx.com\/nl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"nl-NL"}]}},"_links":{"self":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/instruments\/2381","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/instruments"}],"about":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/types\/instruments"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/media\/5238"}],"wp:attachment":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/media?parent=2381"}],"wp:term":[{"taxonomy":"country","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/country?post=2381"},{"taxonomy":"brands","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/brands?post=2381"},{"taxonomy":"applications","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/applications?post=2381"},{"taxonomy":"markets","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/markets?post=2381"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}