{"id":2383,"date":"2023-01-03T15:06:16","date_gmt":"2023-01-03T14:06:16","guid":{"rendered":"https:\/\/chemspx.com\/instruments\/greenhouse-blowdown-evaporator\/"},"modified":"2026-07-17T12:20:24","modified_gmt":"2026-07-17T10:20:24","slug":"greenhouse-blowdown-evaporator","status":"publish","type":"instruments","link":"https:\/\/chemspx.com\/nl\/instruments\/greenhouse-blowdown-evaporator\/","title":{"rendered":"GreenHouse Blowdown Evaporator"},"content":{"rendered":"<h2>Parallel evaporation of chemistry samples in vials, tubes and microtiter plates<\/h2>\n<p class=\"PDq2pG_selectionAnchorContainer\" data-start=\"121\" data-end=\"414\">The GreenHouse Blowdown Evaporator is designed for the <strong>parallel evaporation of chemistry samples and HPLC fractions in 8 or 24 positions.<\/strong> Instead of processing samples individually, the system enables simultaneous evaporation of multiple samples, helping to streamline post-synthesis work-up.<\/p>\n<p data-start=\"416\" data-end=\"581\">The system can be used to upgrade an existing <a href=\"https:\/\/chemspx.com\/instruments\/greenhouse-plus\/\" target=\"_blank\" rel=\"noopener\">GreenHouse Plus Parallel Synthesizer<\/a> for parallel evaporation or purchased as a standalone benchtop evaporation system.<\/p>\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-start=\"914\" data-end=\"947\"><strong data-start=\"914\" data-end=\"947\">Controlled sample evaporation<\/strong><\/h3>\n<p data-start=\"949\" data-end=\"1108\">The GreenHouse Blowdown Evaporator combines digitally controlled heating with a precisely regulated flow of inert gas to provide controlled sample evaporation.<\/p>\n<p data-start=\"1110\" data-end=\"1133\"><strong>Key advantages include:<\/strong><\/p>\n<ul data-start=\"1135\" data-end=\"1550\">\n<li data-section-id=\"ae7qug\" data-start=\"1135\" data-end=\"1213\">No vacuum is required, helping to protect sensitive samples during the evaporation process<\/li>\n<li data-section-id=\"ae7qug\" data-start=\"1135\" data-end=\"1213\">Interchangeable blowdown pin plates with either 8 or 24 hollow pins distribute an equal flow of inert gas to every tube, vial or microtiter well<\/li>\n<li data-section-id=\"ae7qug\" data-start=\"1135\" data-end=\"1213\">Optional flowmeter allows precise adjustment of the drying gas flow<\/li>\n<li data-section-id=\"ae7qug\" data-start=\"1135\" data-end=\"1213\">Nickel-plated aluminum construction provides chemical resistance<\/li>\n<li data-section-id=\"ae7qug\" data-start=\"1135\" data-end=\"1213\">Open design enables observation of samples throughout the evaporation process<\/li>\n<\/ul>\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"p4pts0\" data-start=\"1311\" data-end=\"1349\"><strong>Solvent containment and collection<\/strong><\/h3>\n<p data-start=\"1351\" data-end=\"1586\">The enclosed system contains evaporating solvent, allowing subsequent trapping and collection through a high-performance glass condenser. A safety relief valve on the gas inlet helps prevent overpressure during operation.<\/p>\n<p data-start=\"1588\" data-end=\"1792\">Digital temperature control enables careful adjustment of the evaporation temperature and rate, making it suitable for protecting temperature-sensitive samples while maintaining efficient solvent removal.<\/p>\n<h3 data-section-id=\"wsh87q\" data-start=\"1794\" data-end=\"1823\"><strong>Compatible sample formats<\/strong><\/h3>\n<p data-start=\"1825\" data-end=\"2064\">The GreenHouse Blowdown Evaporator is compatible with a wide range of laboratory sample containers. GreenHouse reaction tubes can be evaporated directly in the standard GreenHouse reaction block without transferring them to another holder.<\/p>\n<p data-start=\"2066\" data-end=\"2093\"><strong>Compatible formats include:<\/strong><\/p>\n<ul data-start=\"2095\" data-end=\"2273\">\n<li data-section-id=\"o28h23\" data-start=\"2095\" data-end=\"2139\">GreenHouse reaction tubes from 0.5 to 7 mL<\/li>\n<li data-section-id=\"3r0yiw\" data-start=\"2140\" data-end=\"2170\">8- or 24-position vial racks<\/li>\n<li data-section-id=\"14wjxez\" data-start=\"2171\" data-end=\"2239\">Vials with diameters of 13 mm, 13.8 mm, 15 mm, 24.3 mm and 27.8 mm<\/li>\n<li data-section-id=\"cb0n7m\" data-start=\"2240\" data-end=\"2273\">8- or 24-well microtiter plates<\/li>\n<\/ul>\n<p data-start=\"2275\" data-end=\"2386\">A selection of vial racks is available for arranging commonly used vial sizes in 6 \u00d7 4 or 4 \u00d7 2 configurations.<\/p>\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1wicyw6\" data-start=\"2388\" data-end=\"2421\"><strong>Flexible system configuration<\/strong><\/h3>\n<p data-start=\"2423\" data-end=\"2616\">It is possible to insert the blowdown adaptor into the GreenHouse base to accommodate vial racks or microtiter plates. Alternatively, users can use the system with the dedicated low-profile Blowdown Base. The removable blowdown head features quick-release handles, allowing rapid exchange of the 8- or 24-position blowdown pin plates according to the application.<\/p>\n<h3 data-section-id=\"16zyfva\" data-start=\"2778\" data-end=\"2794\"><strong>Key features<\/strong><\/h3>\n<ul data-start=\"2796\" data-end=\"3579\">\n<li data-section-id=\"18ascaa\" data-start=\"2796\" data-end=\"2852\">Parallel evaporation of 8 or 24 samples simultaneously<\/li>\n<li data-section-id=\"11yz29g\" data-start=\"2853\" data-end=\"2904\">Suitable for chemistry samples and HPLC fractions<\/li>\n<li data-section-id=\"h02vcz\" data-start=\"2905\" data-end=\"2975\">Available as a GreenHouse Plus upgrade or standalone benchtop system<\/li>\n<li data-section-id=\"1jskgor\" data-start=\"2976\" data-end=\"3029\">Digital temperature control for precise evaporation<\/li>\n<li data-section-id=\"k37qa2\" data-start=\"3030\" data-end=\"3089\">Inert gas blowdown without vacuum to avoid sample bumping<\/li>\n<li data-section-id=\"u477tc\" data-start=\"3090\" data-end=\"3175\">Interchangeable 8- and 24-position blowdown pin plates for uniform gas distribution<\/li>\n<li data-section-id=\"630jrb\" data-start=\"3176\" data-end=\"3258\">Enclosed design for solvent containment and collection through a glass condenser<\/li>\n<li data-section-id=\"h5xpyr\" data-start=\"3259\" data-end=\"3304\">Safety relief valve to prevent overpressure<\/li>\n<li data-section-id=\"rokz2c\" data-start=\"3305\" data-end=\"3376\">Nickel-plated aluminum construction for excellent chemical resistance<\/li>\n<li data-section-id=\"13cmrf4\" data-start=\"3377\" data-end=\"3444\">Direct evaporation of GreenHouse reaction tubes without reloading<\/li>\n<li data-section-id=\"1plpdwg\" data-start=\"3445\" data-end=\"3513\">Compatible with GreenHouse tubes, vial racks and microtiter plates<\/li>\n<li data-section-id=\"mdyf19\" data-start=\"3514\" data-end=\"3579\">Optional flowmeter for precise control of inert drying gas flow<\/li>\n<\/ul>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [{\n    \"@type\": \"Question\",\n    \"name\": \"What is the GreenHouse Blowdown Evaporator?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"The GreenHouse Blowdown Evaporator is a parallel evaporation system designed for the simultaneous evaporation of chemistry samples and HPLC fractions. It can process 8 or 24 samples at the same time, helping laboratories increase throughput and reduce post-synthesis processing time.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"How does the GreenHouse Blowdown Evaporator work?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"The system combines digitally controlled heating with a regulated flow of inert gas to evaporate solvents from multiple samples simultaneously. The inert gas is delivered evenly across all sample positions through interchangeable blowdown pin plates.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"What is parallel evaporation?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Parallel evaporation is the process of removing solvent from multiple samples at the same time. Instead of evaporating each sample individually, laboratories can process several samples simultaneously, improving efficiency and productivity.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Can the GreenHouse Blowdown Evaporator be used for HPLC fractions?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Yes. The system is specifically designed for both chemistry samples and HPLC fractions, making it suitable for sample preparation and post-purification workflows.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Does the GreenHouse Blowdown Evaporator require a vacuum?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"No. The system uses inert gas blowdown rather than vacuum evaporation. This helps protect sensitive samples and reduces the risk of sample bumping during solvent removal.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Why is evaporation without vacuum beneficial?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Vacuum-free evaporation can be gentler on sensitive compounds and helps avoid sample bumping. This allows controlled solvent removal while maintaining sample integrity.\"\n    }\n  }]\n}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Parallel evaporation of chemistry samples and HPLC fractions in 8 or 24 positions<\/p>","protected":false},"featured_media":5720,"template":"","country":[649],"brands":[626],"applications":[587,567,651],"markets":[18,14,115,22,47,110,23],"class_list":["post-2383","instruments","type-instruments","status-publish","has-post-thumbnail","hentry","country-nl","brands-radleys","applications-batch-synthesis-chemistry","applications-chemistry","applications-parallel-reaction","markets-agriculture","markets-chemicals","markets-chemicals-materials","markets-chemicals-chemicals","markets-fertilizers-and-chemicals","markets-materials","markets-specialty-chemicals"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>GreenHouse Blowdown Evaporator | ChemSPX<\/title>\n<meta name=\"description\" content=\"The GreenHouse Blowdown Evaporator is designed for the parallel evaporation of chemistry samples and HPLC fractions in 8 or 24 positions.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/chemspx.com\/nl\/instruments\/greenhouse-blowdown-evaporator\/\" \/>\n<meta property=\"og:locale\" content=\"nl_NL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"GreenHouse Blowdown Evaporator | ChemSPX\" \/>\n<meta property=\"og:description\" content=\"The GreenHouse Blowdown Evaporator is designed for the parallel evaporation of chemistry samples and HPLC fractions in 8 or 24 positions.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/chemspx.com\/nl\/instruments\/greenhouse-blowdown-evaporator\/\" \/>\n<meta property=\"og:site_name\" content=\"ChemSPX\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-17T10:20:24+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/blowdown-evaporator.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1080\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Geschatte leestijd\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/greenhouse-blowdown-evaporator\\\/\",\"url\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/greenhouse-blowdown-evaporator\\\/\",\"name\":\"GreenHouse Blowdown Evaporator | ChemSPX\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/greenhouse-blowdown-evaporator\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/greenhouse-blowdown-evaporator\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/blowdown-evaporator.webp\",\"datePublished\":\"2023-01-03T14:06:16+00:00\",\"dateModified\":\"2026-07-17T10:20:24+00:00\",\"description\":\"The GreenHouse Blowdown Evaporator is designed for the parallel evaporation of chemistry samples and HPLC fractions in 8 or 24 positions.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/greenhouse-blowdown-evaporator\\\/#breadcrumb\"},\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/greenhouse-blowdown-evaporator\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/greenhouse-blowdown-evaporator\\\/#primaryimage\",\"url\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/blowdown-evaporator.webp\",\"contentUrl\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/blowdown-evaporator.webp\",\"width\":1080,\"height\":1080,\"caption\":\"blowdown evaporator\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/greenhouse-blowdown-evaporator\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/chemspx.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Instruments\",\"item\":\"https:\\\/\\\/chemspx.com\\\/instruments\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"GreenHouse Blowdown Evaporator\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/#website\",\"url\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/\",\"name\":\"ChemSPX\",\"description\":\"ChemSPX\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"nl-NL\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"GreenHouse Blowdown Evaporator | ChemSPX","description":"The GreenHouse Blowdown Evaporator is designed for the parallel evaporation of chemistry samples and HPLC fractions in 8 or 24 positions.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/chemspx.com\/nl\/instruments\/greenhouse-blowdown-evaporator\/","og_locale":"nl_NL","og_type":"article","og_title":"GreenHouse Blowdown Evaporator | ChemSPX","og_description":"The GreenHouse Blowdown Evaporator is designed for the parallel evaporation of chemistry samples and HPLC fractions in 8 or 24 positions.","og_url":"https:\/\/chemspx.com\/nl\/instruments\/greenhouse-blowdown-evaporator\/","og_site_name":"ChemSPX","article_modified_time":"2026-07-17T10:20:24+00:00","og_image":[{"width":1080,"height":1080,"url":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/blowdown-evaporator.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Geschatte leestijd":"3 minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/chemspx.com\/nl\/instruments\/greenhouse-blowdown-evaporator\/","url":"https:\/\/chemspx.com\/nl\/instruments\/greenhouse-blowdown-evaporator\/","name":"GreenHouse Blowdown Evaporator | ChemSPX","isPartOf":{"@id":"https:\/\/chemspx.com\/nl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/chemspx.com\/nl\/instruments\/greenhouse-blowdown-evaporator\/#primaryimage"},"image":{"@id":"https:\/\/chemspx.com\/nl\/instruments\/greenhouse-blowdown-evaporator\/#primaryimage"},"thumbnailUrl":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/blowdown-evaporator.webp","datePublished":"2023-01-03T14:06:16+00:00","dateModified":"2026-07-17T10:20:24+00:00","description":"The GreenHouse Blowdown Evaporator is designed for the parallel evaporation of chemistry samples and HPLC fractions in 8 or 24 positions.","breadcrumb":{"@id":"https:\/\/chemspx.com\/nl\/instruments\/greenhouse-blowdown-evaporator\/#breadcrumb"},"inLanguage":"nl-NL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/chemspx.com\/nl\/instruments\/greenhouse-blowdown-evaporator\/"]}]},{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/chemspx.com\/nl\/instruments\/greenhouse-blowdown-evaporator\/#primaryimage","url":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/blowdown-evaporator.webp","contentUrl":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/blowdown-evaporator.webp","width":1080,"height":1080,"caption":"blowdown evaporator"},{"@type":"BreadcrumbList","@id":"https:\/\/chemspx.com\/nl\/instruments\/greenhouse-blowdown-evaporator\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/chemspx.com\/"},{"@type":"ListItem","position":2,"name":"Instruments","item":"https:\/\/chemspx.com\/instruments\/"},{"@type":"ListItem","position":3,"name":"GreenHouse Blowdown Evaporator"}]},{"@type":"WebSite","@id":"https:\/\/chemspx.com\/nl\/#website","url":"https:\/\/chemspx.com\/nl\/","name":"ChemSPX","description":"ChemSPX","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/chemspx.com\/nl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"nl-NL"}]}},"_links":{"self":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/instruments\/2383","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/instruments"}],"about":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/types\/instruments"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/media\/5720"}],"wp:attachment":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/media?parent=2383"}],"wp:term":[{"taxonomy":"country","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/country?post=2383"},{"taxonomy":"brands","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/brands?post=2383"},{"taxonomy":"applications","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/applications?post=2383"},{"taxonomy":"markets","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/markets?post=2383"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}