{"id":2392,"date":"2023-01-03T15:06:37","date_gmt":"2023-01-03T14:06:37","guid":{"rendered":"https:\/\/chemspx.com\/instruments\/gas-module\/"},"modified":"2026-07-23T11:30:21","modified_gmt":"2026-07-23T09:30:21","slug":"gas-module","status":"publish","type":"instruments","link":"https:\/\/chemspx.com\/nl\/instruments\/gas-module\/","title":{"rendered":"Gas Module"},"content":{"rendered":"<h2>Precise gas dosing for flow chemistry applications<\/h2>\n<p class=\"PDq2pG_selectionAnchorContainer\" data-start=\"69\" data-end=\"382\">The Gas Module <strong>enables accurate dosing of gases for flow chemistry applications<\/strong> and integrates seamlessly with the <a href=\"https:\/\/chemspx.com\/instruments\/h-cube-pro-hastelloy\/\" target=\"_blank\" rel=\"noopener\">H-Cube Pro<\/a> and <a href=\"https:\/\/chemspx.com\/instruments\/phoenix-flow-reactor\/\" target=\"_blank\" rel=\"noopener\">Phoenix Flow Reactor<\/a> systems. By extending gas handling capabilities, the module allows a wider range of gas-phase reactions to be performed under controlled conditions.<\/p>\n<p data-start=\"384\" data-end=\"554\">The system supports reactions at<strong> pressures of up to 100 bar<\/strong>, making it suitable for applications such as oxidation, carbonylation, hydroformylation and hydrogenation.<\/p>\n<h3><strong>How does the gas module work?\u00a0<\/strong><\/h3>\n<p class=\"PDq2pG_selectionAnchorContainer\" data-start=\"585\" data-end=\"732\">The Gas Module is designed to operate with an external gas source, typically a gas cylinder supplying gas at a pressure between 25 and 140 bar.<\/p>\n<p data-start=\"734\" data-end=\"751\"><strong>During operation:<\/strong><\/p>\n<ul data-start=\"753\" data-end=\"1104\">\n<li data-section-id=\"92iswi\" data-start=\"753\" data-end=\"882\">The desired gas is selected from the module&#8217;s predefined gas library or a new gas can be configured by entering its properties.<\/li>\n<li data-section-id=\"1bifi50\" data-start=\"883\" data-end=\"974\">A built-in mass flow controller accurately doses the selected gas into the liquid stream.<\/li>\n<li data-section-id=\"1lmryoh\" data-start=\"975\" data-end=\"1104\">The module works together with the H-Cube\u00ae Pro or Phoenix\u2122 Flow Reactor to perform reactions at pressures of up to 100 bar.<\/li>\n<\/ul>\n<p data-start=\"1106\" data-end=\"1267\">This allows gas-phase reactions, including carbonylations and oxidations, to be carried out under elevated pressure, expanding the range of possible chemistries.<\/p>\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"b84wjk\" data-start=\"1269\" data-end=\"1288\"><strong>Compatible gases<\/strong><\/h3>\n<p data-start=\"1290\" data-end=\"1338\">The Gas Module supports 14 predefined gases:<\/p>\n<ul data-start=\"1340\" data-end=\"1598\">\n<li data-section-id=\"1p9t439\" data-start=\"1340\" data-end=\"1356\">Compressed air<\/li>\n<li data-section-id=\"1w7gqw7\" data-start=\"1357\" data-end=\"1372\">Hydrogen (H\u2082)<\/li>\n<li data-section-id=\"axy2hz\" data-start=\"1373\" data-end=\"1388\">Nitrogen (N\u2082)<\/li>\n<li data-section-id=\"ucvupy\" data-start=\"1389\" data-end=\"1402\">Oxygen (O\u2082)<\/li>\n<li data-section-id=\"1v5rl45\" data-start=\"1403\" data-end=\"1425\">Carbon monoxide (CO)<\/li>\n<li data-section-id=\"qjxyfg\" data-start=\"1426\" data-end=\"1449\">Carbon dioxide (CO\u2082)*<\/li>\n<li data-section-id=\"1hrq5so\" data-start=\"1450\" data-end=\"1465\">Methane (CH\u2084)<\/li>\n<li data-section-id=\"5082et\" data-start=\"1466\" data-end=\"1481\">Ethane (C\u2082H\u2086)<\/li>\n<li data-section-id=\"53d91i\" data-start=\"1482\" data-end=\"1499\">Ethylene (C\u2082H\u2084)<\/li>\n<li data-section-id=\"6qqvr1\" data-start=\"1500\" data-end=\"1521\">Nitrous oxide (N\u2082O)<\/li>\n<li data-section-id=\"m6cn98\" data-start=\"1522\" data-end=\"1541\">Nitric oxide (NO)<\/li>\n<li data-section-id=\"3kozvz\" data-start=\"1542\" data-end=\"1554\">Argon (Ar)<\/li>\n<li data-section-id=\"1nuzwt0\" data-start=\"1555\" data-end=\"1568\">Helium (He)<\/li>\n<li data-section-id=\"17ygxuc\" data-start=\"1569\" data-end=\"1598\">Syngas for hydroformylation<\/li>\n<\/ul>\n<p data-start=\"1600\" data-end=\"1703\">Other gases with well-known thermodynamic properties and suitable compatibility can also be introduced.<\/p>\n<p data-start=\"1705\" data-end=\"1730\">*CO\u2082 requires preheating.<\/p>\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"mu966k\" data-start=\"2401\" data-end=\"2416\"><strong>Applications<\/strong><\/h3>\n<p data-start=\"2418\" data-end=\"2509\">The Gas Module is suitable for a range of gas-phase flow chemistry applications, including:<\/p>\n<ul data-start=\"2511\" data-end=\"2573\">\n<li data-section-id=\"1xkdixd\" data-start=\"2511\" data-end=\"2526\">Hydrogenation<\/li>\n<li data-section-id=\"3145u7\" data-start=\"2527\" data-end=\"2538\">Oxidation<\/li>\n<li data-section-id=\"utkp83\" data-start=\"2539\" data-end=\"2554\">Carbonylation<\/li>\n<li data-section-id=\"bafva6\" data-start=\"2555\" data-end=\"2573\">Hydroformylation<\/li>\n<\/ul>\n<h3 data-section-id=\"t4ytit\" data-start=\"2575\" data-end=\"2590\"><strong>Key features<\/strong><\/h3>\n<ul data-start=\"2592\" data-end=\"3074\">\n<li data-section-id=\"1xwyel6\" data-start=\"2592\" data-end=\"2651\">Accurate gas dosing using a built-in mass flow controller<\/li>\n<li data-section-id=\"b0yg88\" data-start=\"2652\" data-end=\"2711\">Compatible with the<a href=\"https:\/\/chemspx.com\/instruments\/h-cube-pro-hastelloy\/\" target=\"_blank\" rel=\"noopener\"> H-Cube Pro<\/a> and <a href=\"https:\/\/chemspx.com\/instruments\/phoenix-flow-reactor\/\" target=\"_blank\" rel=\"noopener\">Phoenix Flow Reactor<\/a><\/li>\n<li data-section-id=\"1e3gppv\" data-start=\"2712\" data-end=\"2763\">Supports reactions at pressures up to 100 bar<\/li>\n<li data-section-id=\"tdo558\" data-start=\"2764\" data-end=\"2801\">Compatible with 14 predefined gases<\/li>\n<li data-section-id=\"15eb6s\" data-start=\"2802\" data-end=\"2848\">User-friendly three-button control interface<\/li>\n<li data-section-id=\"pez0ag\" data-start=\"2849\" data-end=\"2892\">High-quality stainless steel construction<\/li>\n<li data-section-id=\"13cgkvl\" data-start=\"2893\" data-end=\"2942\">Supports reproducible and automated experiments<\/li>\n<li data-section-id=\"1ek4syd\" data-start=\"2943\" data-end=\"3021\">Automated blockage and solvent leak detection when used with the H-Cube Pro<\/li>\n<li data-section-id=\"p3ekm7\" data-start=\"3022\" data-end=\"3074\">Suitable for high-pressure heterogeneous reactions<\/li>\n<\/ul>\n<h3><strong>Technical data\u00a0<\/strong><\/h3>\n<div>\n<table>\n<tbody>\n<tr>\n<th><strong>Inlet pressure<\/strong><\/th>\n<td>Minimum: 25\u202fbar<br \/>\nMaximum: 140\u202fbar<\/td>\n<\/tr>\n<tr>\n<th><strong>Outlet pressure<\/strong><\/th>\n<td>Maximum: 100\u202fbar<\/td>\n<\/tr>\n<tr>\n<th><strong>Flow rate (N\u2082)<\/strong><\/th>\n<td>\u2022 0\u2013100\u202fNmL\/min (Gas Module)<\/td>\n<\/tr>\n<tr>\n<th><strong>MFC calibrating gas<\/strong><\/th>\n<td>Nitrogen (N\u2082)<\/td>\n<\/tr>\n<tr>\n<th><strong>Dimensions (H \u00d7 W \u00d7 D)<\/strong><\/th>\n<td>Height: 21\u202fcm (8.27\u2033)<br \/>\nWidth: 20\u202fcm (7.87\u2033)<br \/>\nDepth: 30\u202fcm (11.8\u2033)<\/td>\n<\/tr>\n<tr>\n<th><strong>Weight<\/strong><\/th>\n<td>8\u202fkg (17.6\u202flb)<\/td>\n<\/tr>\n<tr>\n<th><strong>Power requirements<\/strong><\/th>\n<td>115\u2013230\u202fVAC<br \/>\n47\u201363\u202fHz, 50\u202fVA<\/td>\n<\/tr>\n<tr>\n<th><strong>Fuses<\/strong><\/th>\n<td>\u2022 2 \u00d7 1\u202fA\u2011T \/ 230\u202fVAC<br \/>\n\u2022 2 \u00d7 1.6\u202fA\u2011T \/ 115\u202fVAC<\/td>\n<\/tr>\n<tr>\n<th><strong>Gas inlet connection<\/strong><\/th>\n<td>Male 1\/8\u2033 OD stainless steel, 5\/64\u2033 ID, 1\/64\u2033 wall connection<\/td>\n<\/tr>\n<tr>\n<th><strong>Gas outlet connection<\/strong><\/th>\n<td>1\/16\u2033 stainless steel line with Swagelok fitting and ferrule<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [{\n    \"@type\": \"Question\",\n    \"name\": \"What is the Gas Module for flow chemistry?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"The Gas Module is a gas dosing system designed for flow chemistry applications. It integrates with the H-Cube Pro and Phoenix Flow Reactor to enable accurate dosing of gases for reactions such as hydrogenation, oxidation, carbonylation, and hydroformylation under controlled conditions.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"How does the Gas Module improve gas-liquid flow chemistry?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"The Gas Module uses a built-in mass flow controller to precisely introduce gas into a liquid reaction stream. This allows researchers to perform gas-phase reactions with improved accuracy, reproducibility, and process control.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"What is a mass flow controller in flow chemistry?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"A mass flow controller is a device that precisely measures and regulates the flow rate of gases entering a reaction system. In the Gas Module, it ensures accurate and consistent gas dosing throughout the experiment.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Why is accurate gas dosing important in flow chemistry?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Accurate gas dosing helps maintain consistent reaction conditions, improves reproducibility, optimizes gas consumption, and supports reliable scale-up of gas-liquid reactions.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Why are high-pressure conditions used in gas-liquid reactions?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Elevated pressure can increase gas solubility in liquids, improve reaction efficiency, enhance mass transfer, and enable reaction pathways that may not occur at lower pressures.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"How does the Gas Module work?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"The system connects to an external gas source and uses a mass flow controller to introduce a precisely measured amount of gas into the reaction stream. The selected gas is combined with the liquid feed and processed through the connected flow reactor under controlled pressure and temperature conditions.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"What is hydroformylation and can the Gas Module support it?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Hydroformylation is a reaction that converts alkenes into aldehydes using synthesis gas. The Gas Module supports syngas dosing and can be used for hydroformylation applications.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Why is flow chemistry beneficial for gas-phase reactions?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Flow chemistry improves mixing, heat transfer, and gas-liquid contact while providing safer handling of reactive gases compared with traditional batch processing.\"\n    }\n  }]\n}\n<\/script><\/p>\n<p><script type=\"application\/ld+json\"> \n{ \n  \"@context\": \"https:\/\/schema.org\/\", \n  \"@type\": \"Product\", \n  \"name\": \"Gas Module\", \n  \"image\": \"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/gas-module.jpg\", \n  \"description\": \"The Gas Module enables accurate dosing of gases for flow chemistry applications and supports reactions at pressures up to 100 bar.\", \n  \"brand\": { \n    \"@type\": \"Brand\", \n    \"name\": \"ThalesNano\" \n  }, \n  \"offers\": { \n    \"@type\": \"Offer\", \n    \"url\": \"https:\/\/chemspx.com\/instruments\/gas-module\/\", \n    \"priceCurrency\": \"EUR\", \n    \"price\": \"0.00\", \n    \"availability\": \"https:\/\/schema.org\/InStock\", \n    \"seller\": { \n      \"@type\": \"Organization\", \n      \"name\": \"ChemSPX\", \n      \"url\": \"https:\/\/chemspx.com\", \n      \"logo\": \"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/Logo_ChemSPX-1.png\", \n      \"areaServed\": [ \n        { \"@type\": \"Country\", \"name\": \"Belgium\" }, \n        { \"@type\": \"Country\", \"name\": \"Netherlands\" }, \n        { \"@type\": \"Country\", \"name\": \"Luxembourg\" } \n      ] \n    } \n  } \n} \n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Precise gas dosing for flow chemistry applications<\/p>","protected":false},"featured_media":4949,"template":"","country":[650,649],"brands":[631],"applications":[567,588],"markets":[14,24,23],"class_list":["post-2392","instruments","type-instruments","status-publish","has-post-thumbnail","hentry","country-be","country-nl","brands-thalesnano","applications-chemistry","applications-reactions-with-gases","markets-chemicals","markets-pharmaceuticals","markets-specialty-chemicals"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Gas Module | ChemSPX<\/title>\n<meta name=\"description\" content=\"The Gas Module enables accurate dosing of gases for flow chemistry applications and supports reactions at pressures up to 100 bar.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/chemspx.com\/nl\/instruments\/gas-module\/\" \/>\n<meta property=\"og:locale\" content=\"nl_NL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Gas Module | ChemSPX\" \/>\n<meta property=\"og:description\" content=\"The Gas Module enables accurate dosing of gases for flow chemistry applications and supports reactions at pressures up to 100 bar.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/chemspx.com\/nl\/instruments\/gas-module\/\" \/>\n<meta property=\"og:site_name\" content=\"ChemSPX\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-23T09:30:21+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/gas-module.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"509\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Geschatte leestijd\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/gas-module\\\/\",\"url\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/gas-module\\\/\",\"name\":\"Gas Module | ChemSPX\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/gas-module\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/gas-module\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/gas-module.jpg\",\"datePublished\":\"2023-01-03T14:06:37+00:00\",\"dateModified\":\"2026-07-23T09:30:21+00:00\",\"description\":\"The Gas Module enables accurate dosing of gases for flow chemistry applications and supports reactions at pressures up to 100 bar.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/gas-module\\\/#breadcrumb\"},\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/gas-module\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/gas-module\\\/#primaryimage\",\"url\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/gas-module.jpg\",\"contentUrl\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/gas-module.jpg\",\"width\":800,\"height\":509,\"caption\":\"gas module\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/gas-module\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/chemspx.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Instruments\",\"item\":\"https:\\\/\\\/chemspx.com\\\/instruments\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Gas Module\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/#website\",\"url\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/\",\"name\":\"ChemSPX\",\"description\":\"ChemSPX\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"nl-NL\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Gas Module | ChemSPX","description":"The Gas Module enables accurate dosing of gases for flow chemistry applications and supports reactions at pressures up to 100 bar.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/chemspx.com\/nl\/instruments\/gas-module\/","og_locale":"nl_NL","og_type":"article","og_title":"Gas Module | ChemSPX","og_description":"The Gas Module enables accurate dosing of gases for flow chemistry applications and supports reactions at pressures up to 100 bar.","og_url":"https:\/\/chemspx.com\/nl\/instruments\/gas-module\/","og_site_name":"ChemSPX","article_modified_time":"2026-07-23T09:30:21+00:00","og_image":[{"width":800,"height":509,"url":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/gas-module.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Geschatte leestijd":"3 minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/chemspx.com\/nl\/instruments\/gas-module\/","url":"https:\/\/chemspx.com\/nl\/instruments\/gas-module\/","name":"Gas Module | ChemSPX","isPartOf":{"@id":"https:\/\/chemspx.com\/nl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/chemspx.com\/nl\/instruments\/gas-module\/#primaryimage"},"image":{"@id":"https:\/\/chemspx.com\/nl\/instruments\/gas-module\/#primaryimage"},"thumbnailUrl":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/gas-module.jpg","datePublished":"2023-01-03T14:06:37+00:00","dateModified":"2026-07-23T09:30:21+00:00","description":"The Gas Module enables accurate dosing of gases for flow chemistry applications and supports reactions at pressures up to 100 bar.","breadcrumb":{"@id":"https:\/\/chemspx.com\/nl\/instruments\/gas-module\/#breadcrumb"},"inLanguage":"nl-NL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/chemspx.com\/nl\/instruments\/gas-module\/"]}]},{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/chemspx.com\/nl\/instruments\/gas-module\/#primaryimage","url":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/gas-module.jpg","contentUrl":"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/gas-module.jpg","width":800,"height":509,"caption":"gas module"},{"@type":"BreadcrumbList","@id":"https:\/\/chemspx.com\/nl\/instruments\/gas-module\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/chemspx.com\/"},{"@type":"ListItem","position":2,"name":"Instruments","item":"https:\/\/chemspx.com\/instruments\/"},{"@type":"ListItem","position":3,"name":"Gas Module"}]},{"@type":"WebSite","@id":"https:\/\/chemspx.com\/nl\/#website","url":"https:\/\/chemspx.com\/nl\/","name":"ChemSPX","description":"ChemSPX","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/chemspx.com\/nl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"nl-NL"}]}},"_links":{"self":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/instruments\/2392","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/instruments"}],"about":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/types\/instruments"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/media\/4949"}],"wp:attachment":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/media?parent=2392"}],"wp:term":[{"taxonomy":"country","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/country?post=2392"},{"taxonomy":"brands","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/brands?post=2392"},{"taxonomy":"applications","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/applications?post=2392"},{"taxonomy":"markets","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/markets?post=2392"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}