{"id":5300,"date":"2025-02-17T11:01:32","date_gmt":"2025-02-17T10:01:32","guid":{"rendered":"https:\/\/chemspx.com\/?post_type=instruments&#038;p=5300"},"modified":"2026-05-05T12:18:32","modified_gmt":"2026-05-05T10:18:32","slug":"hydrophobic-surface-treatments-for-adequate-wetting","status":"publish","type":"instruments","link":"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/","title":{"rendered":"Surface Treatments"},"content":{"rendered":"<h2>Surface Treatments for adequate wetting<\/h2>\n<p data-start=\"56\" data-end=\"418\">Emulseo provides easy-to-use hydrophobic surface treatments for microfluidic channel coating to<strong> ensure adequate wetting conditions and improved droplet formation in fluorinated oil systems<\/strong>. These treatments form a covalently bound fluorophilic layer on channel surfaces, improving performance, stability, and reproducibility in microfluidic experiments.<\/p>\n<p data-start=\"420\" data-end=\"559\">The treatments work with Emulseo surfactants and fluorinated oils, supporting consistent droplet-based workflows.<\/p>\n<h2>Overview of Surface Treatments<\/h2>\n<h3><strong>Fluo-ST1<\/strong><\/h3>\n<p data-start=\"597\" data-end=\"907\">Fluo-ST1 is a hydrophobic surface treatment <strong>composed of fluoroalkylsilanes that react with plasma-etched glass and PDMS surfaces.<\/strong> After treatment, a uniform fluorophilic layer is covalently attached to the microfluidic device, resulting in improved droplet stability and performance in fluorinated oil systems.<\/p>\n<p data-start=\"909\" data-end=\"1024\">This coating enhances aqueous droplet formation and stability, and is compatible with Emulseo surfactants and oils.<\/p>\n<p data-start=\"1911\" data-end=\"1926\"><strong data-start=\"1911\" data-end=\"1924\">Benefits:<\/strong><\/p>\n<ul data-start=\"1927\" data-end=\"2041\">\n<li data-section-id=\"1bbz40n\" data-start=\"1927\" data-end=\"1971\">\n<p data-start=\"1929\" data-end=\"1971\">Enhanced droplet formation and stability<\/p>\n<\/li>\n<li data-section-id=\"jfd810\" data-start=\"1972\" data-end=\"1999\">\n<p data-start=\"1974\" data-end=\"1999\">Easy-to-use application<\/p>\n<\/li>\n<li data-section-id=\"rhkjyq\" data-start=\"2000\" data-end=\"2041\">\n<p data-start=\"2002\" data-end=\"2041\">Reproducible microfluidic experiments<\/p>\n<\/li>\n<\/ul>\n<p><strong>General recommendation<\/strong><\/p>\n<p data-start=\"1182\" data-end=\"1382\">For best results, microfluidic channels are filled with the treatment solution, excess is flushed, and the device is typically incubated (e.g. overnight at 65\u00b0C in an oven).<\/p>\n<p data-start=\"2043\" data-end=\"2210\"><strong data-start=\"2043\" data-end=\"2055\">Storage and safety notes:\u00a0<\/strong><\/p>\n<p data-start=\"1384\" data-end=\"1689\">You can store Fluo-ST1 at room temperature in the supplied vial or in a glass syringe purged with argon for up to six months without loss of performance. Replace the needle before every use. We recommend standard protective equipment (gloves, eye and face protection).<\/p>\n<h3><strong>Fluo-ST2<\/strong><\/h3>\n<p data-start=\"2398\" data-end=\"2744\">Fluo-ST2 is a versatile surface treatment reagent in a hydrofluoroether solvent. It contains a fluorosilane polymer that covalently bonds to a wide range of surfaces, including glass, PDMS, COC\/COP, PMMA, and PC. The resulting thin film has excellent hydrophobic properties, which improves droplet performance and stability in fluorinated oils.<\/p>\n<p data-start=\"2746\" data-end=\"2761\"><strong data-start=\"2746\" data-end=\"2759\">Benefits:<\/strong><\/p>\n<ul data-start=\"2762\" data-end=\"2896\">\n<li data-section-id=\"nir0ev\" data-start=\"2762\" data-end=\"2794\">\n<p data-start=\"2764\" data-end=\"2794\">Broad material compatibility<\/p>\n<\/li>\n<li data-section-id=\"14qmq1i\" data-start=\"2795\" data-end=\"2841\">\n<p data-start=\"2797\" data-end=\"2841\">Low-viscosity, low-surface-tension coating<\/p>\n<\/li>\n<li data-section-id=\"7l2opv\" data-start=\"2842\" data-end=\"2896\">\n<p data-start=\"2844\" data-end=\"2896\">Improves droplet stability in microfluidic systems<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"2898\" data-end=\"3019\"><strong data-start=\"2898\" data-end=\"2908\">Usage:<\/strong><br data-start=\"2908\" data-end=\"2911\" \/>Apply Fluo-ST2 to cleaned microfluidic channels and allow it to dry into a thin, uniform hydrophobic film.<\/p>\n<h3><strong>Fluo-ST3<\/strong><\/h3>\n<p data-start=\"1727\" data-end=\"2016\">Fluo-ST3 is a fluorophilic surface treatment consisting of a fluoroalkylsilane dissolved in a perfluorinated polyether solvent. It is a clear, low-viscosity solution with low interfacial tension and is compatible with a wide range of materials including glass, PDMS, COC\/COP, PMMA, and PC.<\/p>\n<p data-start=\"2018\" data-end=\"2338\">After application, a uniform covalently bound layer forms on channel surfaces, making them both hydrophobic and fluorophilic. This improves droplet formation and stability in fluorinated oils and enhances reproducibility in microfluidic experiments. It is especially suitable for use with Emulseo surfactants and oils.<\/p>\n<p data-start=\"3395\" data-end=\"3410\"><strong data-start=\"3395\" data-end=\"3408\">Benefits:<\/strong><\/p>\n<ul data-start=\"3411\" data-end=\"3565\">\n<li data-section-id=\"fwbbgj\" data-start=\"3411\" data-end=\"3459\">\n<p data-start=\"3413\" data-end=\"3459\">Low interfacial tension and easy application<\/p>\n<\/li>\n<li data-section-id=\"yej0i6\" data-start=\"3460\" data-end=\"3497\">\n<p data-start=\"3462\" data-end=\"3497\">Broad material compatibility<\/p>\n<\/li>\n<li data-section-id=\"eh96m9\" data-start=\"3498\" data-end=\"3565\">\n<p data-start=\"3500\" data-end=\"3565\">Improves reproducibility and stability of microfluidic droplets<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3567\" data-end=\"3597\"><strong data-start=\"3567\" data-end=\"3595\">Recommended Application:<\/strong><\/p>\n<ol data-start=\"3598\" data-end=\"3766\">\n<li data-section-id=\"1ax8ozi\" data-start=\"3598\" data-end=\"3648\">\n<p data-start=\"3601\" data-end=\"3648\">Clean the microfluidic chip with isopropanol<\/p>\n<\/li>\n<li data-section-id=\"3nr9ns\" data-start=\"3649\" data-end=\"3707\">\n<p data-start=\"3652\" data-end=\"3707\">Fill channels with Fluo-ST3 and leave for 30 seconds, then flush excess<\/p>\n<\/li>\n<li data-section-id=\"1eiwrt4\" data-start=\"3708\" data-end=\"3766\">\n<p data-start=\"3711\" data-end=\"3766\">Rinse channels with fluorinated oil<\/p>\n<\/li>\n<\/ol>\n<p data-start=\"3768\" data-end=\"3879\"><strong data-start=\"3768\" data-end=\"3780\">Storage:<\/strong><\/p>\n<p data-start=\"2667\" data-end=\"2766\">Fluo-ST3 can be stored at room temperature for up to one year without performance loss.<\/p>\n<p data-start=\"3881\" data-end=\"3993\"><strong data-start=\"3881\" data-end=\"3898\">Safety Notes:<\/strong><\/p>\n<p data-start=\"2768\" data-end=\"2914\">Standard laboratory safety precautions apply, including protective gloves and eye protection, and inhalation of vapours or mist should be avoided.<\/p>\n<h3><strong>Applications of hydrophobic surface treatments:<\/strong><\/h3>\n<ul>\n<li>Improving flow stability in microchannels<\/li>\n<li>Suitable for diagnostics and pharmaceutical applications<\/li>\n<\/ul>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [{\n    \"@type\": \"Question\",\n    \"name\": \"What are hydrophobic surface treatments in microfluidics?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Hydrophobic surface treatments are channel coatings used in microfluidic devices to ensure adequate wetting and stable droplet formation. Emulseo surface treatments create a covalently bound fluorophilic layer that improves droplet stability, reproducibility, and performance when working with fluorinated oil systems.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Why are surface treatments important for droplet microfluidics?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Proper surface wetting is essential for consistent droplet formation and flow stability. Without adequate hydrophobic and fluorophilic surface properties, droplets may wet channel walls, leading to poor reproducibility and unstable microfluidic operation.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Why choose Emulseo surface treatments for microfluidics?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Emulseo surface treatments provide easy\u2011to\u2011use, reproducible, and material\u2011compatible solutions for ensuring proper wetting and droplet stability. Their optimized compatibility with Emulseo oils and surfactants makes them a reliable choice for fluorinated droplet microfluidic workflows.\"\n    }\n  }]\n}\n<\/script><\/p>\n<p><script type=\"application\/ld+json\"> \n{ \n  \"@context\": \"https:\/\/schema.org\/\", \n  \"@type\": \"Product\", \n  \"name\": \"Surface Treatments\", \n  \"image\": \"https:\/\/chemspx.com\/wp-content\/uploads\/2025\/02\/Fluo-ST1-removebg-preview.png\", \n  \"description\": \"Emulseo provides easy-to-use hydrophobic surface treatments for microfluidic channel coating to ensure adequate wetting conditions and improved droplet formation in fluorinated oil systems. These treatments form a covalently bound fluorophilic layer on channel surfaces, improving performance, stability, and reproducibility in microfluidic experiments.\", \n  \"brand\": { \n    \"@type\": \"Brand\", \n    \"name\": \"Emulseo\" \n  }, \n  \"offers\": { \n    \"@type\": \"Offer\", \n    \"url\": \"https:\/\/chemspx.com\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/\", \n    \"priceCurrency\": \"EUR\", \n    \"price\": \"0.00\", \n    \"availability\": \"https:\/\/schema.org\/InStock\", \n    \"seller\": { \n      \"@type\": \"Organization\", \n      \"name\": \"ChemSPX\", \n      \"url\": \"https:\/\/chemspx.com\", \n      \"logo\": \"https:\/\/chemspx.com\/wp-content\/uploads\/2023\/01\/Logo_ChemSPX-1.png\", \n      \"areaServed\": [ \n        { \"@type\": \"Country\", \"name\": \"Belgium\" }, \n        { \"@type\": \"Country\", \"name\": \"Netherlands\" }, \n        { \"@type\": \"Country\", \"name\": \"Luxembourg\" } \n      ] \n    } \n  } \n} \n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Hydrophobic surface treatments for microfluidic channel coating to ensure adequate wetting conditions<\/p>","protected":false},"featured_media":5301,"template":"","country":[650,649],"brands":[667],"applications":[567],"markets":[14,22,23],"class_list":["post-5300","instruments","type-instruments","status-publish","has-post-thumbnail","hentry","country-be","country-nl","brands-emulseo","applications-chemistry","markets-chemicals","markets-chemicals-chemicals","markets-specialty-chemicals"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Surface Treatments for adequate wetting | ChemSPX<\/title>\n<meta name=\"description\" content=\"Easy-to-use hydrophobic surface treatments for microfluidic channel coating to ensure adequate wetting conditions.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/\" \/>\n<meta property=\"og:locale\" content=\"nl_NL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Surface Treatments for adequate wetting | ChemSPX\" \/>\n<meta property=\"og:description\" content=\"Easy-to-use hydrophobic surface treatments for microfluidic channel coating to ensure adequate wetting conditions.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/\" \/>\n<meta property=\"og:site_name\" content=\"ChemSPX\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-05T10:18:32+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/chemspx.com\/wp-content\/uploads\/2025\/02\/Fluo-ST1-removebg-preview.png\" \/>\n\t<meta property=\"og:image:width\" content=\"408\" \/>\n\t<meta property=\"og:image:height\" content=\"612\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Geschatte leestijd\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/hydrophobic-surface-treatments-for-adequate-wetting\\\/\",\"url\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/hydrophobic-surface-treatments-for-adequate-wetting\\\/\",\"name\":\"Surface Treatments for adequate wetting | ChemSPX\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/hydrophobic-surface-treatments-for-adequate-wetting\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/hydrophobic-surface-treatments-for-adequate-wetting\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2025\\\/02\\\/Fluo-ST1-removebg-preview.png\",\"datePublished\":\"2025-02-17T10:01:32+00:00\",\"dateModified\":\"2026-05-05T10:18:32+00:00\",\"description\":\"Easy-to-use hydrophobic surface treatments for microfluidic channel coating to ensure adequate wetting conditions.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/hydrophobic-surface-treatments-for-adequate-wetting\\\/#breadcrumb\"},\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/hydrophobic-surface-treatments-for-adequate-wetting\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/hydrophobic-surface-treatments-for-adequate-wetting\\\/#primaryimage\",\"url\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2025\\\/02\\\/Fluo-ST1-removebg-preview.png\",\"contentUrl\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2025\\\/02\\\/Fluo-ST1-removebg-preview.png\",\"width\":408,\"height\":612,\"caption\":\"hydrophobic surface treatments for adequate wetting\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/instruments\\\/hydrophobic-surface-treatments-for-adequate-wetting\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/chemspx.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Instruments\",\"item\":\"https:\\\/\\\/chemspx.com\\\/instruments\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Surface Treatments\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/#website\",\"url\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/\",\"name\":\"ChemSPX\",\"description\":\"ChemSPX\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"nl-NL\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Surface Treatments for adequate wetting | ChemSPX","description":"Easy-to-use hydrophobic surface treatments for microfluidic channel coating to ensure adequate wetting conditions.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/","og_locale":"nl_NL","og_type":"article","og_title":"Surface Treatments for adequate wetting | ChemSPX","og_description":"Easy-to-use hydrophobic surface treatments for microfluidic channel coating to ensure adequate wetting conditions.","og_url":"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/","og_site_name":"ChemSPX","article_modified_time":"2026-05-05T10:18:32+00:00","og_image":[{"width":408,"height":612,"url":"https:\/\/chemspx.com\/wp-content\/uploads\/2025\/02\/Fluo-ST1-removebg-preview.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Geschatte leestijd":"3 minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/","url":"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/","name":"Surface Treatments for adequate wetting | ChemSPX","isPartOf":{"@id":"https:\/\/chemspx.com\/nl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/#primaryimage"},"image":{"@id":"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/#primaryimage"},"thumbnailUrl":"https:\/\/chemspx.com\/wp-content\/uploads\/2025\/02\/Fluo-ST1-removebg-preview.png","datePublished":"2025-02-17T10:01:32+00:00","dateModified":"2026-05-05T10:18:32+00:00","description":"Easy-to-use hydrophobic surface treatments for microfluidic channel coating to ensure adequate wetting conditions.","breadcrumb":{"@id":"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/#breadcrumb"},"inLanguage":"nl-NL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/"]}]},{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/#primaryimage","url":"https:\/\/chemspx.com\/wp-content\/uploads\/2025\/02\/Fluo-ST1-removebg-preview.png","contentUrl":"https:\/\/chemspx.com\/wp-content\/uploads\/2025\/02\/Fluo-ST1-removebg-preview.png","width":408,"height":612,"caption":"hydrophobic surface treatments for adequate wetting"},{"@type":"BreadcrumbList","@id":"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/chemspx.com\/"},{"@type":"ListItem","position":2,"name":"Instruments","item":"https:\/\/chemspx.com\/instruments\/"},{"@type":"ListItem","position":3,"name":"Surface Treatments"}]},{"@type":"WebSite","@id":"https:\/\/chemspx.com\/nl\/#website","url":"https:\/\/chemspx.com\/nl\/","name":"ChemSPX","description":"ChemSPX","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/chemspx.com\/nl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"nl-NL"}]}},"_links":{"self":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/instruments\/5300","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/instruments"}],"about":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/types\/instruments"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/media\/5301"}],"wp:attachment":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/media?parent=5300"}],"wp:term":[{"taxonomy":"country","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/country?post=5300"},{"taxonomy":"brands","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/brands?post=5300"},{"taxonomy":"applications","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/applications?post=5300"},{"taxonomy":"markets","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/markets?post=5300"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}