{"id":5300,"date":"2025-02-17T11:01:32","date_gmt":"2025-02-17T10:01:32","guid":{"rendered":"https:\/\/chemspx.com\/?post_type=instruments&p=5300"},"modified":"2025-02-17T11:04:17","modified_gmt":"2025-02-17T10:04:17","slug":"hydrophobic-surface-treatments-for-adequate-wetting","status":"publish","type":"instruments","link":"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/","title":{"rendered":"Surface treatments for adequate wetting"},"content":{"rendered":"

Emulseo provides easy-to-use hydrophobic surface treatments for microfluidic channel coating. These treatments optimize fluid flows in materials like PDMS, glass, COC, and PMMA.<\/p>\n

Products:<\/strong><\/h2>\n

Fluo-ST1<\/strong><\/h3>\n

Hydrophobic surface treatment reagent to coat glass and polydimethylsiloxane (PDMS) surfaces. The surface treatment Fluo-ST1 from Emulseo is composed of fluoroalkylsilanes that are chemically reactive to plasma etched glass and PDMS surfaces.<\/p>\n

\n
\n
\n
\n

After treatment, a uniform fluorophobic layer covalently attaches to the surfaces of the microfluidic devices, significantly improving the performance and stability of aqueous droplets that form in fluorinated oils.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n

Fluo-ST1 works with Emulseo\u2019s surfactants and oils.<\/p>\n

 <\/p>\n

Fluo-ST2<\/strong><\/h3>\n

Versatile surface treatment reagent to coat glass, PDMS, COC\/COP, PMMA and PC.<\/p>\n

The surface treatment Fluo-ST2 from Emulseo is a clear, low viscosity, low surface tension solution of a fluorosilane polymer carried in a hydrofluoroether solvent. The coating covalently bonds to a variety of surfaces including glass, PDMS, COC\/COP, PMMA and PC and dries in a thin film with excellent hydrophobic properties. It allows a better performance and stability of aqueous droplets that form in fluorinated oils.<\/p>\n

Fluo-ST2 works with Emulseo\u2019s surfactants and oils.<\/p>\n

 <\/p>\n

Fluo-ST3<\/strong><\/h3>\n

Surface treatment reagent compatible with a wide range of materials including glass, PDMS, COC\/COP, PMMA and PC.<\/p>\n

Fluo-ST3 is a fluorophilic surface treatment composed of a fluoroalkylsilane dissolved in a perfluorinated polyether solvent. Fluo-ST3 is a clear solution with low viscosity, low interfacial tension and compatible with a wide range of materials including glass, PDMS, COC\/COP, PMMA and PC.<\/p>\n

After treatment, a uniform layer covalently attaches to the treated surfaces, making the walls of the microfluidic channels hydrophobic and fluorophilic. This treatment allows a better formation and stability of droplets that form in fluorinated oils.<\/p>\n

Fluo-ST3 works with Emulseo\u2019s surfactants and oils.<\/p>\n

 <\/p>\n

Applications of hydrophobic surface treatments:<\/strong><\/h3>\n
    \n
  • Improving flow stability in microchannels.<\/li>\n
  • Suitable for diagnostics and pharmaceutical applications.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"

    Easy-to-use hydrophobic surface treatments for microfluidic channel coating<\/p>\n","protected":false},"featured_media":5301,"template":"","country":[650,649],"brands":[667],"applications":[567],"markets":[14,22,23],"acf":[],"yoast_head":"\nSurface treatments for adequate wetting - ChemSPX<\/title>\n<meta name=\"description\" content=\"Emulseo provides easy-to-use hydrophobic surface treatments for microfluidic channel coating. Explore Fluo-ST1, Fluo-ST2 and Fluo-ST3.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/\" \/>\n<meta property=\"og:locale\" content=\"nl_NL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Surface treatments for adequate wetting - ChemSPX\" \/>\n<meta property=\"og:description\" content=\"Emulseo provides easy-to-use hydrophobic surface treatments for microfluidic channel coating. Explore Fluo-ST1, Fluo-ST2 and Fluo-ST3.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/\" \/>\n<meta property=\"og:site_name\" content=\"ChemSPX\" \/>\n<meta property=\"article:modified_time\" content=\"2025-02-17T10:04:17+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/chemspx.com\/wp-content\/uploads\/2025\/02\/Fluo-ST1-removebg-preview.png\" \/>\n\t<meta property=\"og:image:width\" content=\"408\" \/>\n\t<meta property=\"og:image:height\" content=\"612\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Geschatte leestijd\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/\",\"url\":\"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/\",\"name\":\"Surface treatments for adequate wetting - ChemSPX\",\"isPartOf\":{\"@id\":\"https:\/\/chemspx.com\/nl\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/chemspx.com\/wp-content\/uploads\/2025\/02\/Fluo-ST1-removebg-preview.png\",\"datePublished\":\"2025-02-17T10:01:32+00:00\",\"dateModified\":\"2025-02-17T10:04:17+00:00\",\"description\":\"Emulseo provides easy-to-use hydrophobic surface treatments for microfluidic channel coating. Explore Fluo-ST1, Fluo-ST2 and Fluo-ST3.\",\"breadcrumb\":{\"@id\":\"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/#breadcrumb\"},\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/#primaryimage\",\"url\":\"https:\/\/chemspx.com\/wp-content\/uploads\/2025\/02\/Fluo-ST1-removebg-preview.png\",\"contentUrl\":\"https:\/\/chemspx.com\/wp-content\/uploads\/2025\/02\/Fluo-ST1-removebg-preview.png\",\"width\":408,\"height\":612,\"caption\":\"hydrophobic surface treatments\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/chemspx.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Instruments\",\"item\":\"https:\/\/chemspx.com\/instruments\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Surface treatments for adequate wetting\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/chemspx.com\/nl\/#website\",\"url\":\"https:\/\/chemspx.com\/nl\/\",\"name\":\"ChemSPX\",\"description\":\"ChemSPX\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/chemspx.com\/nl\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"nl-NL\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Surface treatments for adequate wetting - ChemSPX","description":"Emulseo provides easy-to-use hydrophobic surface treatments for microfluidic channel coating. Explore Fluo-ST1, Fluo-ST2 and Fluo-ST3.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/","og_locale":"nl_NL","og_type":"article","og_title":"Surface treatments for adequate wetting - ChemSPX","og_description":"Emulseo provides easy-to-use hydrophobic surface treatments for microfluidic channel coating. Explore Fluo-ST1, Fluo-ST2 and Fluo-ST3.","og_url":"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/","og_site_name":"ChemSPX","article_modified_time":"2025-02-17T10:04:17+00:00","og_image":[{"width":408,"height":612,"url":"https:\/\/chemspx.com\/wp-content\/uploads\/2025\/02\/Fluo-ST1-removebg-preview.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Geschatte leestijd":"2 minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/","url":"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/","name":"Surface treatments for adequate wetting - ChemSPX","isPartOf":{"@id":"https:\/\/chemspx.com\/nl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/#primaryimage"},"image":{"@id":"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/#primaryimage"},"thumbnailUrl":"https:\/\/chemspx.com\/wp-content\/uploads\/2025\/02\/Fluo-ST1-removebg-preview.png","datePublished":"2025-02-17T10:01:32+00:00","dateModified":"2025-02-17T10:04:17+00:00","description":"Emulseo provides easy-to-use hydrophobic surface treatments for microfluidic channel coating. Explore Fluo-ST1, Fluo-ST2 and Fluo-ST3.","breadcrumb":{"@id":"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/#breadcrumb"},"inLanguage":"nl-NL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/"]}]},{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/#primaryimage","url":"https:\/\/chemspx.com\/wp-content\/uploads\/2025\/02\/Fluo-ST1-removebg-preview.png","contentUrl":"https:\/\/chemspx.com\/wp-content\/uploads\/2025\/02\/Fluo-ST1-removebg-preview.png","width":408,"height":612,"caption":"hydrophobic surface treatments"},{"@type":"BreadcrumbList","@id":"https:\/\/chemspx.com\/nl\/instruments\/hydrophobic-surface-treatments-for-adequate-wetting\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/chemspx.com\/"},{"@type":"ListItem","position":2,"name":"Instruments","item":"https:\/\/chemspx.com\/instruments\/"},{"@type":"ListItem","position":3,"name":"Surface treatments for adequate wetting"}]},{"@type":"WebSite","@id":"https:\/\/chemspx.com\/nl\/#website","url":"https:\/\/chemspx.com\/nl\/","name":"ChemSPX","description":"ChemSPX","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/chemspx.com\/nl\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"nl-NL"}]}},"_links":{"self":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/instruments\/5300"}],"collection":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/instruments"}],"about":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/types\/instruments"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/media\/5301"}],"wp:attachment":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/media?parent=5300"}],"wp:term":[{"taxonomy":"country","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/country?post=5300"},{"taxonomy":"brands","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/brands?post=5300"},{"taxonomy":"applications","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/applications?post=5300"},{"taxonomy":"markets","embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/markets?post=5300"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}