{"id":8125,"date":"2026-11-10T08:00:00","date_gmt":"2026-11-10T06:00:00","guid":{"rendered":"https:\/\/chemspx.com\/?p=8125"},"modified":"2026-10-13T10:28:38","modified_gmt":"2026-10-13T08:28:38","slug":"which-physical-tests-are-important-before-scaling-up-a-solid-dosage-formulation","status":"publish","type":"wiki_post","link":"https:\/\/chemspx.com\/nl\/wiki\/which-physical-tests-are-important-before-scaling-up-a-solid-dosage-formulation\/","title":{"rendered":"Which physical tests are important before scaling up a solid dosage formulation?"},"content":{"rendered":"<p>Before scaling up a solid dosage formulation, the most important physical tests include powder flowability, compaction behavior, particle size distribution, and moisture content analysis. These measurements reveal how a formulation will behave under the mechanical stresses of industrial-scale manufacturing equipment. Getting these tests right at laboratory scale prevents costly failures during scale-up and helps research teams in pharmaceutical development make confident, data-driven decisions about process readiness.<\/p>\n<h2>What physical properties determine whether a formulation is ready to scale?<\/h2>\n<p>A solid dosage formulation is ready to scale when it demonstrates consistent, predictable behavior across four core physical properties: flowability, compactibility, particle size distribution, and moisture content. These properties directly govern how a powder blend will behave in high-throughput tablet presses, capsule fillers, and granulation equipment. If any one of these properties falls outside acceptable limits at lab scale, the problem will be amplified at production scale.<\/p>\n<p>Formulators working in pharmaceutical research and development use a combination of physical tests to build a property profile for each blend. This profile acts as a benchmark: a formulation that passes all relevant tests at small scale is far more likely to perform consistently when batch sizes increase by an order of magnitude or more. The sections below walk through each critical test area in detail.<\/p>\n<h2>How is powder flowability measured in solid dosage development?<\/h2>\n<p>Powder flowability in solid dosage development is measured using a combination of angle of repose, Carr index, Hausner ratio, and dynamic flow testing. Together, these measurements describe how freely a powder moves under gravity and mechanical stress, which directly predicts how consistently it will feed into tablet presses and filling equipment during scale-up.<\/p>\n<p>Each method captures a different aspect of flow behavior:<\/p>\n<ul>\n <li><strong>Angle of repose<\/strong> measures the steepest angle a powder heap can form without collapsing. A lower angle indicates better free-flowing properties.<\/li>\n <li><strong>Carr index and Hausner ratio<\/strong> compare bulk density to tapped density. A high Carr index (above 25%) signals poor flowability and potential bridging or rat-holing in hoppers.<\/li>\n <li><strong>Dynamic flow testing<\/strong> uses rotating drum or shear cell instruments to simulate the flow conditions inside real manufacturing equipment, offering more nuanced data than static methods alone.<\/li>\n<\/ul>\n<p>Poor flowability at lab scale reliably predicts weight variation, content uniformity failures, and tablet defects at production scale. Identifying flow problems early allows formulators to adjust excipient selection or granulation strategy before committing to larger batches.<\/p>\n<h2>What compaction tests are essential before scaling up a tablet formulation?<\/h2>\n<p>The essential compaction tests before scaling up a tablet formulation are compressibility profiling, tabletability assessment, and ejection force measurement. These tests reveal how a powder blend responds to the pressure applied by a tablet press and whether the resulting tablets will have sufficient hardness, low friability, and acceptable disintegration behavior.<\/p>\n<p>A compaction simulator or instrumented tablet press is typically used to generate compaction profiles across a range of pressures. This produces data on:<\/p>\n<ol>\n <li><strong>Tabletability<\/strong>: the relationship between compaction pressure and tablet tensile strength. A steep, linear curve indicates a formulation that compacts well.<\/li>\n <li><strong>Compressibility<\/strong>: how much a powder bed reduces in volume under pressure. This reflects the plasticity and elasticity of the blend.<\/li>\n <li><strong>Compactibility<\/strong>: the ability to form a coherent tablet at a given solid fraction, independent of the pressure applied.<\/li>\n <li><strong>Ejection force<\/strong>: the force required to push a tablet out of the die. High ejection forces can cause sticking, picking, and tooling wear at scale.<\/li>\n<\/ol>\n<p>Running these tests at lab scale using small quantities of material allows research teams to identify formulations that are prone to capping, lamination, or over-compaction before these defects appear in a full production run.<\/p>\n<h2>Why does particle size distribution affect scale-up success?<\/h2>\n<p>Particle size distribution affects scale-up success because it directly influences powder flowability, blend uniformity, compaction behavior, and dissolution rate. When particle size is inconsistent or poorly characterized, the formulation may behave very differently in large-scale equipment than it did in the lab, leading to segregation, content uniformity failures, and unpredictable tablet properties.<\/p>\n<p>Smaller particles tend to have higher surface area and stronger cohesive forces, making them prone to agglomeration and poor flow. Larger particles flow more freely but may segregate from finer excipients during mixing and transfer. The ideal particle size profile for a given formulation depends on the active ingredient, the excipient system, and the intended manufacturing process.<\/p>\n<p>Laser diffraction and dynamic image analysis are the most widely used techniques for characterizing particle size distribution in pharmaceutical formulation research. These methods provide volume-weighted size distributions (D10, D50, D90 values) that can be used to set acceptance criteria and monitor batch-to-batch consistency during development. Establishing tight particle size specifications at lab scale gives scale-up teams a reliable target to match when transitioning to production-scale milling or granulation.<\/p>\n<h2>What role does moisture content play in solid dosage scale-up?<\/h2>\n<p>Moisture content plays a critical role in solid dosage scale-up because it affects powder flow, compaction behavior, chemical stability, and microbial risk. Even small variations in moisture can cause a well-characterized formulation to behave unpredictably in larger equipment, particularly when processing times, ambient conditions, and batch sizes all change simultaneously.<\/p>\n<p>Hygroscopic active ingredients and excipients are especially sensitive. Excess moisture can cause powder caking, reduced flowability, and tablet softening. Too little moisture, on the other hand, can make granules brittle and reduce compactibility. Both extremes create problems that become harder to control as batch size increases.<\/p>\n<p>Loss on drying (LOD) and Karl Fischer titration are the standard analytical methods used to quantify moisture content in solid dosage research. Near-infrared (NIR) spectroscopy is increasingly used for real-time moisture monitoring during granulation and drying steps. Setting defined moisture limits during development and verifying that scaled-up drying processes can reliably hit those limits is an essential part of pre-scale-up characterization.<\/p>\n<h2>Which instruments are used to run these physical tests in the lab?<\/h2>\n<p>The instruments used to run physical tests for solid dosage scale-up include powder rheometers, tap density analyzers, compaction simulators, laser diffraction particle sizers, and moisture analyzers. Each instrument addresses a specific physical property, and together they form the core analytical toolkit for pre-scale-up formulation testing in pharmaceutical research laboratories.<\/p>\n<p>In practice, a well-equipped solid dosage development lab in the Benelux region will typically rely on:<\/p>\n<ul>\n <li><strong>Powder flow analyzers and rheometers<\/strong> for dynamic and static flowability measurement<\/li>\n <li><strong>Tap density testers<\/strong> for Carr index and Hausner ratio determination<\/li>\n <li><strong>Instrumented tablet presses or compaction simulators<\/strong> for full compaction profiling with minimal material consumption<\/li>\n <li><strong>Laser diffraction systems<\/strong> for rapid, reproducible particle size distribution analysis<\/li>\n <li><strong>Karl Fischer titrators and NIR moisture analyzers<\/strong> for quantitative moisture determination<\/li>\n<\/ul>\n<p>The selection of instruments depends on the formulation type, the stage of development, and the regulatory context in which the work is performed. Laboratories operating under GLP or GMP conditions require instruments with validated software, audit trail capability, and appropriate calibration records, considerations that influence both instrument selection and the qualification process before routine use.<\/p>\n<h2>How ChemSPX supports solid dosage formulation testing<\/h2>\n<p>ChemSPX works with pharmaceutical research teams, CROs, and academic laboratories across the Benelux to help select, install, and support the right instruments for pre-scale-up physical testing. The focus is on providing high-end laboratory instrumentation that fits the specific workflow and compliance requirements of each customer.<\/p>\n<p>ChemSPX&#8217;s support covers:<\/p>\n<ul>\n <li>Expert advice on instrument selection for powder characterization, compaction testing, and particle size analysis<\/li>\n <li>Installation and qualification support, including IQ\/OQ services aligned with GMP and GLP requirements<\/li>\n <li>Application-level support from product specialists who understand solid dosage development workflows<\/li>\n <li>Ongoing service and calibration to keep instruments performing reliably throughout the development lifecycle<\/li>\n<\/ul>\n<p>If your team is preparing for a solid dosage scale-up and wants to make sure your physical testing setup is fit for purpose, <a href=\"https:\/\/chemspx.com\/nl\/contact\/\">contact ChemSPX<\/a> to discuss your specific needs with a specialist.<\/p>\n<div class=\"wp-block-seoaic-faq-block\">\n    <h2 class=\"seoaic-faq-section-title\">Veelgestelde vragen<\/h2>\n            <div class=\"seoaic-faq-item\">\n            <h3 class=\"seoaic-question\">\n                In what order should these physical tests be performed during formulation development?            <\/h3>\n            <p class=\"seoaic-answer\">\n                It is generally most efficient to begin with particle size distribution and moisture content analysis, since these properties influence every downstream test. Once the starting material is characterized, flowability testing should follow, and compaction profiling should come last, as it consumes the most material and requires a relatively stable formulation. This sequence allows formulators to identify and resolve fundamental issues early before investing material in more resource-intensive compaction studies.            <\/p>\n        <\/div>\n                <div class=\"seoaic-faq-item\">\n            <h3 class=\"seoaic-question\">\n                How much material is typically needed to run a complete pre-scale-up physical test package?            <\/h3>\n            <p class=\"seoaic-answer\">\n                Modern compaction simulators and powder rheometers are designed to work with small quantities, and a full pre-scale-up test package can often be completed with as little as 50\u2013200 grams of blend, depending on the instruments used and the number of replicates required. Laser diffraction particle sizing and Karl Fischer titration require only milligram-to-gram quantities. Minimizing material consumption is especially important in early development when the active ingredient is expensive or available in limited quantities.            <\/p>\n        <\/div>\n                <div class=\"seoaic-faq-item\">\n            <h3 class=\"seoaic-question\">\n                What are the most common mistakes formulators make when interpreting flowability data?            <\/h3>\n            <p class=\"seoaic-answer\">\n                One of the most frequent mistakes is relying solely on angle of repose or Carr index without running dynamic flow testing, which can lead to overly optimistic conclusions about how a powder will behave under the mechanical stress of real manufacturing equipment. Another common error is testing the blend immediately after preparation without accounting for the effects of time, humidity, or electrostatic charge, all of which can significantly alter flow behavior before the material reaches the production floor. Using multiple complementary methods and testing under conditions that mimic actual processing environments gives a far more reliable picture.            <\/p>\n        <\/div>\n                <div class=\"seoaic-faq-item\">\n            <h3 class=\"seoaic-question\">\n                Can a formulation with poor compactibility still be successfully scaled up?            <\/h3>\n            <p class=\"seoaic-answer\">\n                Yes, but it typically requires a formulation intervention before scale-up rather than after. Common strategies include switching to more plastically deforming excipients such as microcrystalline cellulose, optimizing the binder system, or adjusting the granulation process to improve compactibility. Attempting to compensate for poor compactibility purely by increasing compaction pressure at scale is rarely sustainable, as it tends to drive up ejection forces and increase the risk of tablet defects such as capping and lamination.            <\/p>\n        <\/div>\n                <div class=\"seoaic-faq-item\">\n            <h3 class=\"seoaic-question\">\n                How do ambient conditions in the production facility affect the physical test data collected in the lab?            <\/h3>\n            <p class=\"seoaic-answer\">\n                Temperature and relative humidity in the production environment can differ significantly from controlled laboratory conditions, and these differences can cause measurable changes in flowability, moisture content, and compaction behavior, particularly for hygroscopic formulations. It is good practice to conduct at least some physical tests under humidity conditions that reflect the actual manufacturing environment, or to define a humidity range within which the formulation&#8217;s physical properties remain within acceptable limits. This information should be captured in the formulation&#8217;s design space documentation to guide technology transfer.            <\/p>\n        <\/div>\n                <div class=\"seoaic-faq-item\">\n            <h3 class=\"seoaic-question\">\n                At what stage of development should particle size specifications be formally set?            <\/h3>\n            <p class=\"seoaic-answer\">\n                Particle size specifications are typically defined during late-stage formulation development, once the manufacturing process has been selected and the relationship between particle size and critical quality attributes such as content uniformity and dissolution has been established. Setting specifications too early, before the process is locked, risks creating targets that are difficult to achieve consistently at scale. However, tracking particle size data from the earliest batches is strongly recommended, as this longitudinal dataset becomes the foundation for setting scientifically justified acceptance criteria.            <\/p>\n        <\/div>\n                <div class=\"seoaic-faq-item\">\n            <h3 class=\"seoaic-question\">\n                Do these physical tests need to be repeated after technology transfer to a contract manufacturing organization (CMO)?            <\/h3>\n            <p class=\"seoaic-answer\">\n                Yes, it is standard practice to repeat key physical characterization tests on the first batches manufactured at the CMO site to confirm that the formulation behaves consistently in a different facility, with different equipment, and under potentially different environmental conditions. Differences in mixer geometry, granulator type, or dryer configuration can all affect particle size distribution, moisture content, and flow behavior even when the formulation itself has not changed. Establishing bridging data between the development site and the CMO is an important part of a robust technology transfer package.            <\/p>\n        <\/div>\n        <\/div>","protected":false},"template":"","class_list":["post-8125","wiki_post","type-wiki_post","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Which physical tests are important before scaling up a solid dosage formulation? | ChemSPX<\/title>\n<meta name=\"description\" content=\"Scaling up a solid dosage formulation? Learn which physical tests, flowability, compaction, particle size, and moisture, prevent costly failures. Read the full guide.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/chemspx.com\/nl\/wiki\/which-physical-tests-are-important-before-scaling-up-a-solid-dosage-formulation\/\" \/>\n<meta property=\"og:locale\" content=\"nl_NL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Which physical tests are important before scaling up a solid dosage formulation? | ChemSPX\" \/>\n<meta property=\"og:description\" content=\"Scaling up a solid dosage formulation? Learn which physical tests, flowability, compaction, particle size, and moisture, prevent costly failures. Read the full guide.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/chemspx.com\/nl\/wiki\/which-physical-tests-are-important-before-scaling-up-a-solid-dosage-formulation\/\" \/>\n<meta property=\"og:site_name\" content=\"ChemSPX\" \/>\n<meta property=\"og:image\" content=\"https:\/\/chemspx.com\/wp-content\/uploads\/2026\/10\/tablet-press-scientist-pharmaceutical-lab.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"768\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Geschatte leestijd\" \/>\n\t<meta name=\"twitter:data1\" content=\"10 minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/wiki\\\/which-physical-tests-are-important-before-scaling-up-a-solid-dosage-formulation\\\/\",\"url\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/wiki\\\/which-physical-tests-are-important-before-scaling-up-a-solid-dosage-formulation\\\/\",\"name\":\"Which physical tests are important before scaling up a solid dosage formulation? | ChemSPX\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/wiki\\\/which-physical-tests-are-important-before-scaling-up-a-solid-dosage-formulation\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/wiki\\\/which-physical-tests-are-important-before-scaling-up-a-solid-dosage-formulation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/tablet-press-scientist-pharmaceutical-lab.webp\",\"datePublished\":\"2026-11-10T06:00:00+00:00\",\"description\":\"Scaling up a solid dosage formulation? Learn which physical tests, flowability, compaction, particle size, and moisture, prevent costly failures. Read the full guide.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/wiki\\\/which-physical-tests-are-important-before-scaling-up-a-solid-dosage-formulation\\\/#breadcrumb\"},\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/chemspx.com\\\/nl\\\/wiki\\\/which-physical-tests-are-important-before-scaling-up-a-solid-dosage-formulation\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/wiki\\\/which-physical-tests-are-important-before-scaling-up-a-solid-dosage-formulation\\\/#primaryimage\",\"url\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/tablet-press-scientist-pharmaceutical-lab.webp\",\"contentUrl\":\"https:\\\/\\\/chemspx.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/tablet-press-scientist-pharmaceutical-lab.webp\",\"width\":1024,\"height\":768,\"caption\":\"Gloved hands pressing a white tablet in a stainless steel tablet press, with powder sample vials and hardness tester on a pharmaceutical lab bench.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/wiki\\\/which-physical-tests-are-important-before-scaling-up-a-solid-dosage-formulation\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/chemspx.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Wiki post\",\"item\":\"https:\\\/\\\/chemspx.com\\\/Wiki\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Which physical tests are important before scaling up a solid dosage formulation?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/#website\",\"url\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/\",\"name\":\"ChemSPX\",\"description\":\"ChemSPX\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/chemspx.com\\\/nl\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"nl-NL\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Which physical tests are important before scaling up a solid dosage formulation? | ChemSPX","description":"Scaling up a solid dosage formulation? Learn which physical tests, flowability, compaction, particle size, and moisture, prevent costly failures. Read the full guide.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/chemspx.com\/nl\/wiki\/which-physical-tests-are-important-before-scaling-up-a-solid-dosage-formulation\/","og_locale":"nl_NL","og_type":"article","og_title":"Which physical tests are important before scaling up a solid dosage formulation? | ChemSPX","og_description":"Scaling up a solid dosage formulation? Learn which physical tests, flowability, compaction, particle size, and moisture, prevent costly failures. Read the full guide.","og_url":"https:\/\/chemspx.com\/nl\/wiki\/which-physical-tests-are-important-before-scaling-up-a-solid-dosage-formulation\/","og_site_name":"ChemSPX","og_image":[{"width":1024,"height":768,"url":"https:\/\/chemspx.com\/wp-content\/uploads\/2026\/10\/tablet-press-scientist-pharmaceutical-lab.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Geschatte leestijd":"10 minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/chemspx.com\/nl\/wiki\/which-physical-tests-are-important-before-scaling-up-a-solid-dosage-formulation\/","url":"https:\/\/chemspx.com\/nl\/wiki\/which-physical-tests-are-important-before-scaling-up-a-solid-dosage-formulation\/","name":"Which physical tests are important before scaling up a solid dosage formulation? | ChemSPX","isPartOf":{"@id":"https:\/\/chemspx.com\/nl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/chemspx.com\/nl\/wiki\/which-physical-tests-are-important-before-scaling-up-a-solid-dosage-formulation\/#primaryimage"},"image":{"@id":"https:\/\/chemspx.com\/nl\/wiki\/which-physical-tests-are-important-before-scaling-up-a-solid-dosage-formulation\/#primaryimage"},"thumbnailUrl":"https:\/\/chemspx.com\/wp-content\/uploads\/2026\/10\/tablet-press-scientist-pharmaceutical-lab.webp","datePublished":"2026-11-10T06:00:00+00:00","description":"Scaling up a solid dosage formulation? Learn which physical tests, flowability, compaction, particle size, and moisture, prevent costly failures. Read the full guide.","breadcrumb":{"@id":"https:\/\/chemspx.com\/nl\/wiki\/which-physical-tests-are-important-before-scaling-up-a-solid-dosage-formulation\/#breadcrumb"},"inLanguage":"nl-NL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/chemspx.com\/nl\/wiki\/which-physical-tests-are-important-before-scaling-up-a-solid-dosage-formulation\/"]}]},{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/chemspx.com\/nl\/wiki\/which-physical-tests-are-important-before-scaling-up-a-solid-dosage-formulation\/#primaryimage","url":"https:\/\/chemspx.com\/wp-content\/uploads\/2026\/10\/tablet-press-scientist-pharmaceutical-lab.webp","contentUrl":"https:\/\/chemspx.com\/wp-content\/uploads\/2026\/10\/tablet-press-scientist-pharmaceutical-lab.webp","width":1024,"height":768,"caption":"Gloved hands pressing a white tablet in a stainless steel tablet press, with powder sample vials and hardness tester on a pharmaceutical lab bench."},{"@type":"BreadcrumbList","@id":"https:\/\/chemspx.com\/nl\/wiki\/which-physical-tests-are-important-before-scaling-up-a-solid-dosage-formulation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/chemspx.com\/"},{"@type":"ListItem","position":2,"name":"Wiki post","item":"https:\/\/chemspx.com\/Wiki\/"},{"@type":"ListItem","position":3,"name":"Which physical tests are important before scaling up a solid dosage formulation?"}]},{"@type":"WebSite","@id":"https:\/\/chemspx.com\/nl\/#website","url":"https:\/\/chemspx.com\/nl\/","name":"ChemSPX","description":"ChemSPX","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/chemspx.com\/nl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"nl-NL"}]}},"_links":{"self":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/wiki_post\/8125","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/wiki_post"}],"about":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/types\/wiki_post"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/media\/8170"}],"wp:attachment":[{"href":"https:\/\/chemspx.com\/nl\/wp-json\/wp\/v2\/media?parent=8125"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}