ACCQPrep HP150

Preparative HPLC system designed for efficient compound purification, from analytical method scouting to preparative-scale separations
Flow range from 1 mL/min to 150 mL/min
Operating pressure up to 6,000 psi
Analytical scouting and preparative purification on one system

ACCQPrep HP150

High Performance Liquid Chromatography System

The ACCQPrep HP150 from Teledyne LABS is a high-performance liquid chromatography (HPLC) system designed for preparative purification and method development. Combining accurate gradient control with intuitive operation, it enables chemists to develop separation methods, scale up purification and collect target compounds using a single platform.

Unlike HPLC systems primarily designed for analytical measurements, the ACCQPrep HP150 focuses on compound isolation and recovery. Its wide flow range supports both analytical scouting and preparative chromatography, reducing the need to transfer methods between separate instruments.

From analytical scouting to preparative purification

The ACCQPrep HP150 uses dual-piston, high-pressure pumps to deliver accurate solvent gradients with low dwell volumes. The system operates at flow rates from 1 to 150 mL/min and supports analytical columns as well as preparative columns of 50 mm diameter and larger.

This flexibility allows researchers to perform an initial scouting run on an analytical column and subsequently scale up the separation for preparative purification, without changing pump heads. The system is particularly suited to laboratory workflows where method development, compound purification and fraction collection are closely connected.

Simplified operation with PeakTrak software

The ACCQPrep HP150 is controlled through Teledyne LABS’ integrated PeakTrak® software. Its touchscreen interface provides access to system parameters without requiring a separate computer.

PeakTrak simplifies preparative chromatography by reducing unnecessary method complexity while retaining control over separation and fraction collection. Active solvent and waste level monitoring helps reduce the risk of spills, while RFID-enabled collection racks support reliable fraction collection. Software upgrades are provided free of charge.

Focus Gradient Generator for method optimization 

The integrated Focus Gradient Generator simplifies the development of preparative HPLC methods by optimizing the solvent gradient around a selected target compound.

After completing a scouting run on the ACCQPrep HP150 or a calibrated analytical HPLC system, the user can select the target peak or enter its retention time. The software then generates a focused gradient method designed to improve resolution around that compound.

The method can be automatically scaled to the selected preparative column size, provided that matching stationary-phase media are used. By improving separation around the target peak, focused gradients can support increased sample loading and more efficient purification while reducing the need for repeated method development.

Scouting and focused runs

You can perform a scouting run (left) on the ACCQPrep HP150 or from a calibrated analytical system. By selecting the peak of interest or entering its retention time, an optimized method for scale-up is generated.

During the focused run (right), improved resolution can be observed, enabling increased sample loading and higher throughput while minimizing method development time.

Scouting Run vs Focused Run

Flexible detection and fraction collection

The ACCQPrep HP150 offers UV and UV-Vis detection using photodiode array (PDA) technology. Spectral information can be displayed during or after a chromatographic run, with fraction collection supported by purity indicators.

For compounds with limited UV absorbance, an optional integrated evaporative light scattering detector (ELSD) provides an alternative detection method. The ELSD module integrates into the system without requiring additional bench space and automatically adjusts peak alignment for different solvent mixtures and flow rates.

Mass-directed purification with PurIon

For more selective compound identification and fraction collection, the ACCQPrep HP150 can be combined with PurIon. PurIon integrates with PeakTrak software to support mass-directed preparative HPLC, allowing researchers to identify target compounds using mass spectrometry before committing valuable samples to purification.

Key features

  • Integrated PeakTrak® software: touchscreen-based control of chromatography parameters without a separate PC

  • Dual-piston high-pressure pumps: accurate solvent gradient delivery with low dwell volumes

  • Wide flow range: operation from 1 to 150 mL/min without changing pump heads

  • Analytical-to-preparative scale-up: supports scouting runs and preparative separations using the same system

  • Focus Gradient Generator: generates optimized gradients around a selected target peak and supports scale-up to columns with matching stationary-phase media.

  • PDA detection: UV and UV-Vis detection options with real-time and post-run spectral display

  • Purity-based fraction collection: supports fraction collection using chromatographic purity indicators

  • Solvent and waste monitoring: active level monitoring helps reduce the risk of solvent spills

  • RFID-enabled collection racks: support accurate fraction collection and help prevent tube overfilling

  • Compact design: integrated touchscreen and software reduce the need for additional equipment

  • Optional automation modules: expand sample injection and automated purification capabilities

  • Optional integrated ELSD: enables detection of compounds with weak UV absorbance, with automatic peak alignment

  • Optional PurIon MS integration: supports mass-directed fraction collection, SIM and target compound identification

  • Free software upgrades: PeakTrak software updates are available at no cost

Questions about your application?

Our Xperts are happy to answer your questions and provide additional information about this instrument and its applications.

Frequently asked questions

Liquid chromatography is an analytical technique in which a solvent, known as the mobile phase, carries a mixture of compounds through a column filled with a stationary phase. This stationary phase most commonly consists of silica gel, which is why the technique is sometimes referred to as gel permeation chromatography. Liquid chromatography is widely used for both quantitative analysis and preparative purification of compounds.
Analytical HPLC primarily focuses on identifying, separating or quantifying compounds in a sample. Preparative HPLC is designed to isolate and collect separated compounds for further use. The ACCQPrep HP150 supports analytical scouting and preparative purification on the same platform.
The Focus Gradient Generator is a method optimization tool integrated into PeakTrak software. It uses the retention time of a selected peak to generate a solvent gradient focused on improving separation around the target compound.
The system is suitable for analytical columns and preparative columns up to 50 mm in diameter and larger, depending on configuration.
Yes. The optional integrated ELSD module enables detection of compounds with weak UV absorbance, making it useful when conventional UV detection is insufficient.
Yes. When combined with the optional PurIon mass spectrometer, the system supports mass-directed fraction collection. PeakTrak integration allows users to select target masses and monitor relevant mass signals during purification.

Downloads

AccqPrep HP150 brochure

Related instruments

ReaXus LS Class

Single-headed, positive displacement piston pumps designed for reliable operation and very low pulsation
Pressures up to 6,000 psi
Ideal for a wide variety of applications

RediSep Flash Chromatography Columns

Easy purification and scale-up from milligram to kilogram
Superior performance and reliability
High-capacity purification capabilities

CombiFlash NextGen 300+

The CombiFlash NextGen 300+ comes standard with all options installed
Flow rates from 1 to 300 mL/min
Operating pressure up to 300 psi (20 bar)