Choose your region:

Only available in The Netherlands

Radleys

Findenser Air Condenser

Replaces water-cooled condensers in more than 95% of common chemistry applications
Suitable for solvent volumes from 5 mL to 1 L
Eliminates the need for running cooling water
Helps lower water consumption and associated operating costs

Findenser Air Condenser

Water-free reflux condenser for common laboratory chemistry applications

The Findenser Air Condenser is a water-free alternative to traditional water-cooled reflux condensers. Designed for solvent volumes from 5 mL to 1 L, it replaces water-cooled condensers in more than 95% of common chemistry applications while eliminating the need for a continuous water supply.

By removing running water from the reflux process, Findenser helps reduce water consumption, lowers water purchase and disposal costs, and eliminates the risk of laboratory flooding associated with water-cooled condensers. It also supports laboratory sustainability and water reduction initiatives.

How Findenser works

The patented Findenser design combines an internal glass condenser with an external finned aluminum jacket. A small amount of water is permanently sealed between the glass condenser and the aluminum jacket, creating a sealed assembly that maximizes thermal conductivity and heat transfer.

The internal glass condenser provides a larger surface area than a conventional air condenser, while the finned aluminum jacket further increases the external cooling surface. Together, these features provide efficient air cooling without the need for running water.

Design features

The Findenser Air Condenser is designed for straightforward integration into existing laboratory setups.

Key design features include:

  • Patented sealed construction with encapsulated thermofluid for efficient heat transfer
  • Finned aluminum jacket for high-performance air cooling
  • Chemically resistant anodized surface
  • Standard ground glass joints compatible with tapered glass sockets
  • Compatible with conventional laboratory clamps
  • Optional clamping kits and PTFE adapters available
  • Contoured anti-roll design that helps prevent rolling and protects the aluminum fins when the condenser is not in use

Available models

Findenser

Suitable for vessels up to 2 L with a maximum solvent volume of 1 L.

  • Length: 400 mm
  • Maximum flask size: 2 L
  • Maximum solvent volume: 1 L
  • Available with a choice of three joint sizes
  • Compatible with standard laboratory clamps
  • Optional clamping kits and PTFE adapters available

Findenser Mini

Designed for smaller-scale reflux applications using vessels up to 250 mL with a maximum solvent volume of 125 mL.

  • Length: 275 mm
  • Maximum flask size: 250 mL
  • Maximum solvent volume: 125 mL
  • Available with a choice of three joint sizes
  • Compatible with standard laboratory clamps
  • Optional clamping kits and PTFE adapters available

Key benefits

  • Replaces water-cooled condensers in more than 95% of common chemistry applications
  • Suitable for solvent volumes from 5 mL to 1 L
  • Eliminates the need for running cooling water
  • Reduces the risk of laboratory flooding
  • Helps lower water consumption and associated operating costs
  • Supports laboratory sustainability and water reduction goals
  • Provides efficient air cooling through a patented sealed condenser design

Technical specifications: 

Findenser Findenser Mini
Length x Diameter 400mm x 72mm 275mm x 72mm
Joints B19, B24, B29 B14, B19, B24
Weight 1200g 670g
Inner or wetted parts Borosilicate glass Borosilicate glass
Finned jacket Anodized aluminum Anodized aluminum
Plug and Seal Acetal & HT Silicone Acetal & HT Silicone
Thermofluid Water Water
Max solvent bpt 155˚C 155˚C
Oven drying Max Temp. 60˚C 60˚C
Dishwasher Max Temp. 50˚C 50˚C
Autoclaving Do Not Autoclave Do Not Autoclave
Ambient operating temp. 0˚C to 24˚C 0˚C to 24˚C

 

Questions about your application?

Our Xperts are happy to answer your questions and provide additional information about this instrument and its applications.

Frequently asked questions

The Findenser combines an internal glass condenser with an external finned aluminum jacket. A small amount of water is permanently sealed between the glass and aluminum components, creating an efficient heat-transfer system that cools solvent vapors without requiring a continuous water supply.
A water-free reflux condenser eliminates the need for running cooling water during reflux. This helps reduce water consumption, lowers operating costs, and removes the risk of leaks or flooding associated with water-cooled condensers.
Yes. The Findenser is designed to replace water-cooled condensers in more than 95% of common laboratory chemistry applications.

Many laboratories are adopting water-free condensers to reduce water usage, improve sustainability, lower utility costs, and simplify reflux setups without compromising cooling performance.
No. The Findenser operates entirely without a running water supply, making it suitable for laboratories looking to reduce water consumption and simplify equipment setup.
By eliminating the need for continuously running cooling water, the Findenser helps reduce water consumption, water purchase costs, wastewater generation, and the environmental impact associated with reflux cooling.

Yes. The anodized aluminum surface is designed to provide chemical resistance for routine laboratory applications.

Downloads

Findenser Air Condenser Brochure

Related instruments

GreenHouse Blowdown Evaporator

Parallel evaporation of chemistry samples and HPLC fractions in 8 or 24 positions
Suitable for chemistry samples and HPLC fractions
Digital temperature control for precise evaporation

Cool-It

Designed to maintain temperatures below -70 °C significantly longer than conventional alternatives
Small bowl for round-bottom flasks up to 400 mL
Large bowl for round-bottom flasks up to 2 L

Last viewed products

No products found

Contact our Xperts

Prefer to give us a call?

Belgium & Luxembourg
+32 (02)2 334 22 70

The Netherlands
+31 (0)294 280 599

Please select your country

By selecting your country, we can show you the products that are available for you and your organisation.