PurIon Mass Spec for Flash and Prep Labs
The PurIon™ Mass Spectrometer is designed to provide highly affordable mass-directed fractionation to labs performing flash and prep purifications on Teledyne ISCO systems. The PurIon interfaces seamlessly with the CombiFlash® NextGen, CombiFlash® EZ Prep, and ACCQPrep® to instantly verify the identity of target compounds. The innovative PeakTrak® software provides single point of control, three predetermined ionization settings, and the ability to customize ionization parameters to maximize signal strength. Use the convenient Ion Finder utility to identify fragments and adducts of your compound and optimize detection parameters from directly injected samples prior to purification. Highly accessible and easy-to-use, PurIon is ideal for chemists wanting high-quality mass spectral data without the need for specialized training.
Single Quadrupole Mass Analyzer
The PurIon is a compact, single-quadrupole mass analyzer with an atmospheric pressure interface optimized for chromatography purification. PurIon provides highly reliable molecular weight information about target compounds as well as other adducts during the purification run—or by direct-injection analysis prior to purification—in positive ion mode via proton attachment (M+H)+ and negative ion mode via proton removal (M-H)-
Versatile and Reliable
Co-eluting peaks are easily isolated by mass selectivity based on mass-to-charge ratio (m/z) of the target analyte. With both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) capabilities, PurIon delivers rapid and reliable confirmation of compounds in normal-phase and reverse-phase applications. Detect both small and large molecules with extended mass range from 10 Da to 2000 Da.
“S” Model
The “S” Model has an operation range of 10 to 1,200 Da (m/z). The unit can be fitted with either an ESI or APCI ion source. These sources can be quickly exchanged in response to different application needs. Unlike the Base Model, the “S” Model automatically switches between positive and negative ionization modes throughout the run. A fluid interface module is included with the PurIon Mass Spectrometer to remove miniscule sample from the purification flow stream and redirect this portion to the mass spectrometer for analysis.
“L” Model
The L Model has an operation range of 10 to 2,000 Da (m/z). The unit can be fitted with either an ESI or APCI ion source. These sources can be quickly exchanged in response to different application needs. Like the “S” Model, the “L” Model automatically switches between positive and negative ionization modes throughout the run. A fluid interface module is included with the PurIon Mass Spectrometer to remove miniscule sample from the purification flow stream and redirect this portion to the mass spectrometer for analysis.
No more TLC plates for flash. Really?
Yes, really, with the Focused Gradient Generator for flash. Read the info here.