The proprietary technology allows manually controlled or fully automated experiments.
Chemists have complete control with Asia flow chemistry system.
It simplifies setting up and running manual or automated experiments. Production scales range from mg to kg, with adjustable temperatures, pressures, and reaction times.
With all wetted materials offering maximum chemical resistance, an Asia system will give you years of continuous service.
Winner of the R&D 100 Award for innovative technology, the Asia Flow Chemistry System is a benchmark of excellence in continuous flow. It is proven in over 500 publications.
Smooth and accurate pumping
The Asia Syringe Pump is at the heart of the flow systems, providing incredibly smooth flow rates over the complete range of dynamic flow rates.
Two independent flow channels, each with an integrated pressure sensor, provide an accurate flow rate range from 1 ?L to 10 mL/min. Precise flow rates with extremely smooth pressure output are essential. They enable the greatest control of your flow chemistry experiments in drug discovery.
Flexible flow experiments
Asia offers a range of reactors, including glass microreactors, tube reactors, and solid phase column reactors in a range of configurations and sizes.
Optimized for heat and mass transfer, Asia reactors give you the greatest flexibility when designing your flow chemistry experiment.
Tailored to your chemistry
Asia modules are available in a variety of pre-configured systems designed to perform specific flow chemistry applications.
Whatever system you choose, you can continuously expand your flow chemistry capabilities and explore new chemical spaces by adding modules whenever needed.
Flow chemistry systems can be as simple – or as advanced – as your chemistry requires. All Asia modules are interchangeable, giving you the freedom to configure a system of your own. Take control of the functionality and tailor the system to suit your chemistry.
If you need help with choosing your system modules, speak to one of our xperts.
Specifications
Temperature Range | -100°C to +250°C |
---|---|
Flow Rate | 1 μL/min to 10 mL/min per pump channel |
Residence Times | 1 second to multiple hours |
Pressure Range | 0 to 20bar (300psi) |
Liquid Phase Reactor Volumes | 62.5 µL, 250 µL, and 1,000 µL for glass microchips, 4 mL and 16 mL for tube reactors |
Solid Phase Reactor Volumes | 0.7 mL, 2.4 mL, 5.6 mL, and 12 mL |
Wetted Parts | Glass, PTFE and PCTFE (stainless steel and hastelloy possible) |
Mixing | Rapid diffusion mixing |
Production Volumes | Milligrams to Kilograms |