Precise external temperature control from -32 °C to 150 °C
The LAUDA Integral T process thermostats exist for professional external temperature control applications requiring accurate and efficient temperature management between -32 and 150 °C.
With tailored heating and cooling capacities in combination with small internal volumes, the Integral T series enables rapid temperature changes and effective control of external temperature-controlled processes. The systems are suitable for applications where temperature conditions need to be adjusted quickly and reliably.
Working range
- Working temperature min.: -30°C
- Working temperature max.: 150°C
- Temperature stability: 0.05 ± K
Efficient temperature control for changing processes
The Integral T process thermostats feature an open hydraulic system that allows rapid aeration and outgassing without loss of functionality. This design makes them particularly suitable for temperature control processes involving frequent changes of consumers or test objects.
A powerful submersible pump and an integrated bypass for pressure limitation come as standard. These features support reliable operation while providing protection for pressure-sensitive consumers. The heating and cooling functions operate independently of the application flow rate, allowing the flow to be interrupted when necessary, for example during consumer changes.
Flexible integration and communication
The LAUDA Integral T series uses a modular interface concept that enables flexible integration into different user processes. Standard interfaces include Ethernet, USB and Pt 100. Users can add additional interfaces and communication protocols through modular expansions, allowing them to adapt the process thermostats to specific networking requirements. Remote monitoring and maintenance are available via LAUDA.LIVE.
Key benefits
The Integral T process thermostats provide:
- External temperature control from -32 to 150 °C
- Rapid heating and cooling changes
- High heating and cooling output
- Quick aeration and outgassing
- High output and working pressures
- Protection for pressure-sensitive consumers
- Flexible process integration through modular interfaces
- Remote monitoring and maintenance via LAUDA.LIVE
Available models
| Product | Min. working temperature | Max. working temperature | Max. heater power | Cooling output at 20 °C (60 Hz) |
|---|---|---|---|---|
| Integral IN 130 T | -32 °C | 120 °C | 2.7 kW | 1.4 kW |
| Integral IN 230 T | -32 °C | 120 °C | 2.7 kW | 2.2 kW |
| Integral IN 230 TW | -32 °C | 120 °C | 2.7 kW | 2.3 kW |
| Integral IN 530 T | -32 °C | 120 °C | 8 kW | 5 kW |
| Integral IN 530 TW | -32 °C | 120 °C | 8 kW | 6 kW |
| Integral IN 1030 T | -32 °C | 150 °C | 8 kW | 11 kW |
| Integral IN 1330 TW | -32 °C | 150 °C | 16 kW | 13 kW |
| Integral IN 1830 TW | -32 °C | 150 °C | 16 kW | 19 kW |